Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC SIMULBARI T E PO VILL SIMULBARI PS KURSEONG DIST DARJEELING PIN 734009 WEST BENGAL | SIMULBARI | DARJEELING | WEST BENGAL | 734009 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹42.4 L+₹2.4 L (5.96%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹42.8 L+₹2.8 L (7.04%)Rejected-Finance HAKIMPARA NEAR PAKURTALA MORE SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹42.9 L+₹2.9 L (7.32%)Rejected-Finance DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 | JALPAIGURI | WEST BENGAL | 734004 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹43.2 L+₹3.2 L (7.95%)Rejected-Finance 45 9 6 BAGHAJATIN COLONY PO PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING WB | 734403 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Sept 2021, 6:00 pmClosed
Garrison Engineer sukna
Garrison Engineer sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR MAINTENANCE AND PAINTING OF LT HT POLES PANELS BUS BAR CHAMBERS WITH ALLIED WORK IN ADALPUR POWER HOUSE AND KLP POWER AREA UNDER GE SUKNA
2021_MES_472150_1
GE Sukna/8331
Open Tender
Civil Works
Item Rate
270 days
Sukna
AS PER NIT
7 documents required · 7 mandatory
₹500
GE Sukna
₹80,000
Yes
27 Sept 2021
1 Sept 2021
23 Sept 2021
1 Sept 2021
21 Sept 2021
15 Sept 2021
1 Sept 2021 - 8 Sept 2021
Amount
M&L brick work with sub class 'B' brick, straight or curved on plan exc. 6 m mean radius built in CM 1:6 including demolition complete all as specified and directed.
M&L 10 mm thick rendering in CM 1:3 on fair faces of brick work or concrete surfaces as in ceiling, chajja, soffits etc, and finished even and smooth without using extra cement and including taking down complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces, finished even and fair and including taking down complete all as specified and directed.
M&L 15 mm thick rendering in CM 1:4 on fair faces of brick work or concrete surface using water proofing compound as per manufacturers instructions finished even and smooth without using extra cement and including taking down complete all as specified and directed. Note:- WPC shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed. Make:- Fosroc chemicals / STP Ltd / M/s Sika India Ltd / Hindcon Chemicals Limited / M/s IWL Limited
M&L preparation of new plastered ceiling surfaces and inlcuding applying three coats of white wash complete all as specified and directed. Make :- Rajasthan / Apple / Surya
M&L preparation of new plastered ceilng surfaces and including applying two coats of oil bound distemper over a coat of primer and over one coat of wall care putty (0.5 to 1 mm thick) to obtain smooth finish complete all as specified and directed. Make of oil bound distemper :- Bison (Berger) / Tractor (Asian) / ICI (Super Cote) Make of wall care putty:- Birla / Berger / J&N / Shalimar Paints / Asian Paints
M&L preparation of new plastered wall surfaces and including applying two coats of cement base paint over a coat of primer complete all as specified and directed. Make :- Jotun India Pvt Ltd / Snowcem Plus / Berger Paints / Asian Paints (Gutucam) / Crimocem Super Cement paints
M&L preparation of old painted wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and including applying one coat of synthetic enamel paint complete all as specified and directed. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
M&L preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and including applying one coat of synthetic enamel paint complete all as specified and directed. Make:- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
M&L making good broken / damaged RCC chajjas with PCC 1:2:4 type B1 or cement mortar 1:3 and including rendering 15 mm thick in CM 1:4 mixed with water proofing compound as per manufacturer's instruction to top, sides and soffits, including necessary scaffolding, formwork upto 3 storey height complete all as specified and directed. Note:- Water proofing compound shall be measured and paid seperately
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, embedded in concrete, brick work, masonry, etc, and including taking out embedded portion and making good disturbed ground complete all as specified and directed.
M&L for mild steel work in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc,) and including all necessary drilling, bolting or riveting, etc, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F in repairs galvanised. 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc, complete all as as specified and directed (each line wire to be measured).
Supply only chain link MS galvanized fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc, and including provision of binding wire including dismantling complete all as specified and directed.
M&L mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F mild steel screw bolts diameter of neck 11 to 15 mm (machine made) with hexoganal or square heads at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, exc. 10 cm but not exc. 15 cm long complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. Make :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
S&F FRLS PVC insulated 3 core multistranded sheathed cable with 2.5 Sqmm copper conductor for connection of street / security light etc, including taking down complete all as specified and directed. Make:- Havells / KEI / Polycab / RR Kabel Ltd. / HPL
Supply & laying LT XLPE insulated, armoured heavy duty electric cable with alumimium conductor, 1100 volts grade, cross sectional area 16 Sqmm x 4 Core, laid in trenches / duct / on pole including taking downcomplete all as specified and directed. Make :- Havells / KEI / Polycab
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc, laying of cables etc, on plan and n exc 1.5 m in depth and getting out all excavated material in soft / loose soil complete all as specified and directed.
All as per Sl item No. 23 above but exc 1.5 m & not exc 3.0 m in depth
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L sand cushioning with clean and dry sand in trenches for protection of UG cable and including punning down complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Supply & laying sub class 'B' bricks of old size, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.
M&L hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
Surface dressing not exc. 15 cm deep as in soft / loose soil complete all as specified and directed.
M&L preparation of 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and including applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per existing colour code complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
All as per Sl. item No. 31 above but 11 m long HT pole
M&L preparation of 8 m long old PCC / PSC pole with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of weather coat paint exterior emulsion paint on complete height of the pole and including applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the existing colour code complete all as specified and directed. Make of exterior emulsion paint : Royal acrylic (crimson paints pvt ltd) / Dulax / shalimar paints ltd (Extra maximum ultra) / Berger paints ltd (weather coat) / Asian paints ltd (Appex ultima) / Jotun India pvt ltd Make of sythetic enamel paint : Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
M&L preparation of old HT steel 4 pole structure with connected cross arms, cable protection pipes, clamps etc, and including applying one coat of aluminium paint on complete height and including applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with multi colour strips as per the existing colour code complete all as specified and directed. Make of paint :- Jotun India Pvt Ltd / Apcolite (Asian) / Luxol (Berger) / Jenson & Nicholson Paints Ltd (Borolac) / Shalimar Paints Ltd (Superlac)
All as per Sl. item No. 34 above but HT 2 pole structure
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws, type 410 SP-64 (12 m long) and including painting with two coat of aluminium paint over a coat of primer & taking down complete all as specified and directed. Make of Pole:- Skipper Limited / Jindal Steel / Natonal tubing Co / Bombay tube & Store / Calcutta Poles & Tubes Make of paint :- Jotun India Pvt Ltd / Asian Paints / Berger / Jenson & Nicholson Paints Ltd / Shalimar Paints Ltd
S&F framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 (Gde-E-165) including taking down complete all as specified and directed.
M&L air termination, single pointed, copper rod 12 mm dia and 600 mm long with all necessary nuts, washers bolts etc. complete all as specified and directed.
S&F 500 watt LED flood light fitting, IP-65 (minimum) with luminous efficacy 100 Lumen/watt (minimum), pressure die cast aluminium housing, internally prewired and including electrically connecting & taking down complete all as specified and directed. Make:- C&S / Indiabulls LED / Crompton / Surya / Orient Electric Ltd. / HPL / Jaquar & Company Pvt Ltd / Eveready Industries India Ltd. / Havells
M&L earth continuity conductor or main earthing lead using 25 x 3 mm galvanised iron strip fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and directed.
S&F in repairs 6 KW, three phase, automatic street light control panel with and including digital timer switch for automatic switching on / off street light as per set time through programmable 24 hour switch, 32A, TP power contactor, 40A SPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed. Make:- Havells / GE / Kakatiya energy system Pvt Ltd
M&L repairs to existing LT panel / bus bar chamber / feeder pillar box of size not less than of 1000 x 1000 x 500 mm by excavation of all loops and removing damaged UG cable, connecting new thimbles / lugs / cable glands and fixing of new neoprene rubber gasket to make it completely dust and vermin proof, fixing of new locking arragement and replacement of LT panel wiring with appropriate size of copper conductor, repairing of rusted parts of panel frame and shutter with necessary welding works including preparation and applying one coat of synthetic enamel paint on both internal and external surface of panel, PCC (1:3:6) type C2 (using 40mm crushed stone aggregate) work in foundation complete all as specified and directed. Note:-The unit rate quoted is deemed to include cost of earth work, PCC in foundation, new thimbles / lugs / cable glands, neoprene rubber gaskets, locking arrangement, Wiring, welding works, painting.
All as per Sl. item No. 42 above but size 1200 x 1200 x 500 mm to 1800 x 1500 x 600 mm.
S&F phase indicator lamps (Red, Yellow and blue) suitable for existing panel and including taking down complete all as specified and directed. Make:- L&T / Siemens / GE / RR Micro / BCH / Schneider
S&F current transformer, Ratio - 200 / 5, accuracy class 0.5, burden - 4VA including taking down complete all as specified and directed. Make :- AE / English Electric / Crompton Greaves / Areva T&D / Schneider
S&F MCCB 4 pole 63 Amps breaking capacity 25 KA, Ics = 100% Icu and including spreader terminal with thermal magnetic protection unit of suitable size and taking down complete all as specified and directed. Make :- L&T / Havells (Brand- HIM & HIX) / Panasonic / Hager / ABB / Legrand
All as per Sl item No. 48 above but 100 Amp
All as per Sl item No. 48 above but 200 Amp, breaking capacity 36 kA.
All as per Sl item No. 48 above but 250 Amp, breaking capacity 36 kA.
All as per Sl item No. 48 above but 400 Amp, breaking capacity 36 kA.
S&F street light junction box made from CPRI approved factory having size 200 (Width) x 150 (Depth) x 250 (Height) mm (minimum dimensions) made out of 2.00 mm thick CRCA sheet, duly powder coated of approved shade over a coat of red oxide primer both internally and externally, with rain shed all side except back side, comprising of 02 nos copper bus-bar of size 20 x 4 mm mounted on suitable size spacer insulators, necessary cable entry / exit holes for upto 35 sqmm cables, nut-bolts, MS clamps of suitable size for fixing including dismantling complete all as specified & as directed.
M&L for roof treatment in order of precedence as given below complete all as specified and as directed:- (i) Taking out of existing water proofing treatment and including padding, cleaning the surface using wire brush, brooming down and washing down with water to remove dust etc, and brushing with neat cement slurry @ 3.00 kg of cement per Sqm. (ii) 15 mm thick screed bed in CM 1:4 on surface. (iii) Cleaning of plastered surface and applying one coat of bituminous primer @ 0.40 Ltr / Sqm. (Contd...)
(iv) Supply and laying 3 mm (Minimum) thick APP based polymeric membrane of approved manufacturer with weight not less than 3.60 Kg per Sqm, reinforced with non-woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (v) Applying one coat of water proofing paint with aluminium finish over APP as per manufacturer's instruction. Note :- (a) Bituminous primer shall be "ShaliTex Primer" manufactured by M/s STP Ltd or equivalent in M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (b) Laying APP based polymeric membrane shall be done by torch on method as per manufactures instructions. (c) A minimum overlap of 100 mm and 75 mm should be made at the end and sides of the polymeric membrane respectively and all overlaps and joints shall be sealed as per manufacturers instruction. (d) APP based polymeric membrane shall be “SUPER THERMOLAY” manufactured by M/s STP Ltd or “WP Shield” manufactured by M/s Sika India Pvt Ltd or equivalent of M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (e) Water proofing paint shall be by M/s STP Ltd or M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited
Janata Enterprises
SHRI N.DAS
M/S B B CONSTRUCTION
Jagatbandhu Enterprises
M/s TALCO
GEETA CONSTRUCTION
Embee associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .