REPAIR MAINTENANCE OF HT DISTRIBUTION SYSTEM, HT EQUIPMENTS AT SITE R AT AF STN SHEVA UNDER GE (AF) THANE
2026_MES_793252_1
82773/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Thane
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF Thane
₹20,000
Yes
10 Oct 2026
10 Oct 2026
5 Nov 2026
10 Oct 2026
29 Oct 2026
24 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for end terminal cable jointing kit for 22 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. | 2 | Each | - | - |
| 2 | M&L for end terminal cable jointing kit for 22 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. | 3 | Each | - | - |
| 3 | M&L for cable jointing kit for 22 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including dismantling & taking out old unserviceable jointing kit complete all as specified & as directed. | 2 | Each | - | - |
| 4 | Dehydration and filtration of transformer oil filled in transformer installed at different locations,testing of oil after dehydration to achieve dielectric strength not less than 40 KV for 1 minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity with the permissible limit complete all as specified and directed by Engr-in-charge. | 1,250 | Ltrs | - | - |
| 5 | Supply & fixing in replacement of ceramic HV bushing with gun metal bushing stud, nuts and washers for transformer of capacities 160/250 KVA all as specified and directed by Engr In Charge. | 4 | Each | - | - |
| 6 | Supply & fixing in replacement of ceramic LV bushing with bushing stud (Brass Metal), nuts and washers for transformer of capacities 160/250 KVA all as specified and directed by Engr In Charge. | 4 | Each | - | - |
| 7 | Supply and filling fresh tansformer oil confiming to IS 335 having die electric strenght up to 50 KV with oil testing kit 2 mm thick top up transformer complete all as specified and as directed by Engr In Charge. | 210 | Ltr | - | - |
| 8 | Disconnecting of incoming & outgoing cable from both side of transformer indoor/ outdoor type including all accessories, loading unloading and transportation from site to work shop as per site requirement and back to site after carried out repairs & assembling , including connection for the capacity 160 KVA to 250 KVA and commissioning and testing complete all as specified and directed by Engr In Charge.Note: Gasket set,LT/HT Side ceramic bushing,spindle for HT/LT side,rewinding ,dehydration of oil shall be measured and paid separately in respective items. | 3 | Each Job | - | - |
| 9 | Taking out defective HT winding and M& L for rewinding of HT coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 KVA complete all as specified and directed by Engr In Charge. | 60 | Kgs | - | - |
| 10 | M& L for rewinding of LT coil with super enameled best quality copper wire of existing gauge with superior quality insulation material for transformer of capacity 160 to 250 KVA complete all as specified and directed by Engr In Charge. | 50 | Kgs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
82773PS.pdf
Tender Documents • 0.56 MB
BOQ_889568.xls
BOQ • 1.31 MB
82773TD.pdf
Tender Documents • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .