Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Ok |
Tender Value
₹2.8 L
EMD Value
₹5,696
Closing Date
9 Mar 2026, 6:00 pmClosed
EE(C), CD-I
O/o EE(C), CD-I, Burrabazar Telephone Exchange, 3rd Floor, Burrabazar Telephone Exchange, 148, C. R. Avenue Kol-7
Miscellaneous Civil Works ic removal of risky loose unsound weak concrete chunks from RCC members Stair well and roof repairing down slab roof etc at Type II Qtr of Alipure Telephone Exchange Compound 2nd Call
2026_BSNL_269046_1
08/CD-I/BSNL/Kol/2025-26
Open Tender
Civil Works
Works
60 days
Alipote TE
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
BSNL COLLECTION ACCOUNT AO BSNL CENTRAL COLL ACCT
₹5,696
11 Mar 2026
27 Feb 2026
11 Mar 2026
27 Feb 2026
9 Mar 2026
27 Feb 2026
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain windowsills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
1:5:10 (1 cement : 5 coarse sand(zone-III) : 10 graded stone aggregate 40 mm nominal size).
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1½:3 (1 cement : 1½ coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for :
Suspended floors, roofs, landings, balconies and access platform
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.
Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Locally best available seasoned hard wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws excluding, panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.. (Note:Butt hinges and necessary screws shall be paid separately) (a) Locally best available seasoned hard wood
35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick .
Locally best available seasoned hard wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
40 mm thick with 20 mm nominal size stone aggregate
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc.,., complete.
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 coarse sand)
Neat cement punning
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete :
New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade.
Old work (one or more coats)
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :
With cement mortar 1:4 (1cement: 4 coarse sand).
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
Float glass panes of thickness 4 mm (weight not less than 10kg/sqm)
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.
Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.
Orissa pattern W.C Pan of size 580x440 mm
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :
3 mm thick
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead and 20 metres lift as per direction of Engineer in-charge
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings :
Flat back wash basin of size 550x400 mm.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. a) Flexible pipe
32 mm dia
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
20 mm nominal outer dia. Pipes.
25 mm nominal outer dia. Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. : Internal work – Exposed on wall.
15 mm dia. nominal bore
20 mm dia. nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions : a) 45 cm length
15 mm nominal bore
Providing and fixing PTMT bib cock of approved quality and colour.
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
Providing and fixing PTMT stop cock of approved quality and colour.
15 mm nominal bore, 86mm long. Weighing not less than 88 gms.
Providing and fixing PTMT pillar cock of approved quality and colour .
15mm nominal bore, 107 mm long. Weighing not less than 110 gms.
Providing and fixing PTMT swiveling shower, 15mm nominal bore. Weighing not less than 40gms.
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:
(i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
Bars upto 12 mm diameter
Bars above 12 mm diameter
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
25 mm average thickness in 2 layers.
Providing and fixing high pressure PVC ball valve (Solvent Weld) of make Supreme or equivalent with pressure class SCH:80 of approved quality including the cost of necessary uPVC socket, pieces of pipes etc. required for the work complete as per direction of Engineer-in-Charge :
20 mm dia. nominal bore
Supplying of Styles & rails for wooden door / window shutters complete. (Payment to be made on area of new work only). (i) 35 mm thick shutter (a)Local hard wood
Easing door, window shutters with / without removing and refixing the same as per direction of the Engineer - in - charge.
Repairing of damaged door, window shutter i/c dismembering the parts & refixing the same after repairing with same/new screws all complete as per direction by the engineer-in charge (payment of new panels, styles, rails hinges shall be paid in respective item).
Dismantling, removing Chockage & refixing of G.I Pipes up to 50 mm dia and stacked in position as directed.
Supplying, fitting and fixing PVC flushing cistern parts after removing the defective parts complete as per direction of the Engineer-in-Charge.
Polythene syphone with nut , plunger plate, plunger rod and lifting device complete.
Handle lever set for PVC flushing cistern.
Labour charges for fixing of wash basin in the wall after cleaning with all necessary clamps and finishing the fitting with white cemtn etc. after completion of repairing work as per direction of Engineer-in-charge.
Repairing cistern i/c cleaning, washing with muriatic acid and refixing the existing fittings complete.
Removing chokage of urinal, water closet ( Indian & European type) and waste trap and clean with acid.
Cleaning the glazed walls/flooors tiles including sanitary fittings of WC/Bath etc. with oxalic acid , broom, brush and scrapper all complte per direction of engineer -in- charge.
Taking out old damage terfelt from existing roof surface without damaging the roof slab and disposal of rubbish witin a lead of 50m and preparation of roof surface with 6mm thick cement morter at damage portion to receive new Tarfelt as per the direction of engineer in charge.
Uprooting and removing small plants of girth of exposed stem up to 75 mm from the surface of walls, parapets etc. at any height by cutting chase for removing roots to prevent further growth of plants and mending good damages complete.
Small plant of girth of exposed stem up to 75mm
Providing and fixing on wall face unplasticised Rigid PVC pipes of Supreme or equivalent conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes.
110 mm diameter
Credit value for dismantled unserviceable materials
Brass Stop cock/ Bib cock cock.
Pillar cock.
G.I. pipe 15 mm
G.I. pipe 20 mm
G.I. pipe 25 mm
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
NIT8.pdf
Tender Documents • 3.39 MB
BOQ_313242.xls
BOQ • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .