| 1 | Qualified Make: AQUAFRESH
Model: 250 lph 1 379 R H B BHIWADI SECTOR 01 BHIWADI BHIWADI TIZARA ALWAR RAJASTHAN 301019 UDYAM RJ 02 0012085 08BPBPK4129M2ZO R 09BPBPK4129M1ZN M | ALWAR | RAJASTHAN | 301019 | Make: AQUAFRESH
Model: 250 lph | - | Qualified | |
| 2 | L1₹10,500Disqualified Make: UNICORN
Model: Unicorn NEN RO 15L Water Purifier 301019 ALWAR RAJASTHAN 301019 | ALWAR | RAJASTHAN | 301019 | Make: UNICORN
Model: Unicorn NEN RO 15L Water Purifier | L1 | Disqualified | |
| 3 | Disqualified Make: BLUE STAR
Model: Blue Star Majesto BORIYAKALA RAIPUR CHHATTISGARH 492015 INDIA | RAIPUR | CHHATTISGARH | 492015 | Make: BLUE STAR
Model: Blue Star Majesto | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 May 2018, 3:00 pmClosed
Potable water purification system Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier
Gravity operated water purifier Ultraviolet (UV) LAMP Yes Yes
No Ultra Voilet (UV) Lamp power consumption 100 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 1000 1000
2000
3000
4000
5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 90-100 25-35
30-40
90-100
70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity 250 10
25
50
100
250
500 1/3 (Litre/Hour): Arsenic and Floride removal capability true Misc
warranty etc Thin-film composite membrane No Yes
No High Pressure Pump No - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes
No Pre Filter Vessels: No Yes
No Micron Filter Yes Yes
No Membrane Housing No Yes
No Auto cut Yes Yes
No No of candles (Nos) 2 Installation Type Wall mounted Table top
Wall mounted
Floor mounted Warranty period ( for free replacement of machine 2 2
3
1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2
1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm No Yes
No Chloride & Flouride removal facility Yes without pump Yes with Pump
Yes without pump
No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/3 1 Phool Singh Kanwar 495449
Govt ITI Pali
Near Tahsil Office 1 15 EMD Required No ePBG Required No
104735
GEM/2018/B/14945
Potable water purification system
15 days
Chhattisgarh; Korba
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Potable water purification system Experience with Gov. Required 2 Year (s) Potable Water Purification System ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EQUIPMENT TYPE & FEATURES Type Electrically Operated Reverse Osmosis based water purifier Electrically Operated Reverse Osmosis based water purifier | - | - | - |
| Gravity operated water purifier Ultraviolet (UV) LAMP Yes Yes | - | - | - |
| No Ultra Voilet (UV) Lamp power consumption 100 - STANDARDS Conformity to Indian Standrad for System IS 14724 (latest) for water purification system with Ultraviolet disinfection - Number of float valves/sensors 1 INPUT PARAMETERS Input Water TDS 1000 1000 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 5000 OUTPUT PARAMETERS Recovery at 27 degree Centigrade 90-100 25-35 | - | - | - |
| 30-40 | - | - | - |
| 90-100 | - | - | - |
| 70- 80 Output Water of RO system Conforming to Indian Standard IS 10500(latest) - Output water capacity 250 10 | - | - | - |
| 25 | - | - | - |
| 50 | - | - | - |
| 100 | - | - | - |
| 250 | - | - | - |
| 500 1/3 (Litre/Hour): Arsenic and Floride removal capability true Misc | - | - | - |
| warranty etc Thin-film composite membrane No Yes | - | - | - |
| No High Pressure Pump No - Raw water/Chemical Raw water/Chemical Cleaning PUMP No Yes | - | - | - |
| No Pre Filter Vessels: No Yes | - | - | - |
| No Micron Filter Yes Yes | - | - | - |
| No Membrane Housing No Yes | - | - | - |
| No Auto cut Yes Yes | - | - | - |
| No No of candles (Nos) 2 Installation Type Wall mounted Table top | - | - | - |
| Wall mounted | - | - | - |
| Floor mounted Warranty period ( for free replacement of machine 2 2 | - | - | - |
| 3 | - | - | - |
| 1 Warranty Period (for scope including free of cost candle and activated carbon onsite replacement twice a year) 2 2 | - | - | - |
| 1 Antiscalant- where silica is up to 100 ppm/where Mica is up to 100 ppm No Yes | - | - | - |
| No Chloride & Flouride removal facility Yes without pump Yes with Pump | - | - | - |
| Yes without pump | - | - | - |
| No Test Report Availability of type test report(Design Evalution Reports) as per IS:14724 and IS 10500 Yes - Test certificate No and date: - - Name and Address of laboratory which conducted Test: - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 2/3 1 Phool Singh Kanwar 495449 | - | - | - |
| Govt ITI Pali | - | - | - |
| Near Tahsil Office 1 15 EMD Required No ePBG Required No | - | - | - |
Exempted
28 May 2018
18 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_104735.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .