Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.4 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹42.8 L+₹4.2 L (10.8%)Rejected-Finance | L2 | Rejected-Finance Other than L1 Bidder | |
| 3 | L3₹43.3 L+₹4.7 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Other than L1 Bidder | |
| 4 | L4₹45.6 L+₹7.0 L (18.1%)Rejected-Finance | L4 | Rejected-Finance Other than L1 Bidder | |
| 5 | L5₹45.9 L+₹7.2 L (18.7%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L5 | Rejected-Finance Other than L1 Bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
14 Jan 2022, 6:00 pmClosed
Garrison Engineer Gwalior
Garrison Engineer Morar Cantt Gwalior
8732/GWL/E8 REPAIR/ MAINTENANCE AND REPLACEMENT OF UNSERVICEABLE SUB MAIN WIRING, LT SERVICE CONNECTIONS, BLDG SECURITY LIGHTS, BLDG EARTHING AND CONNECTED WORKS AT MORAR CANTT GWALIOR UNDER GE GWALIOR
2021_MES_497273_1
8732/GWL/E8
Open Tender
Electrical and Maintenance Works
Works
180 days
Garrison Engineer Gwalior
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer Gwalior
₹96,000
Yes
9 Feb 2022
24 Dec 2021
18 Jan 2022
24 Dec 2021
14 Jan 2022
7 Jan 2022
Amount
Taking down u/s LED bldg security light Tube light & recess mounted ceiling light fittings of any wattage from bldgs/ceiling of bldgs for repair/ replacement of LED drivers. Dismantling the light fitting part by part, replace the dtiver, reassemble at the existing bracket and re-fixing the same complete all as directed by Engr-in-charge (Note: LED driver will be measured and paid separately as supply only)
Supply only LED drivers suitable for Recess mounting 2"x2" LED light fittings of 36 watt complete.
Supply only LED drivers suitable for bldg security light fittings of 25/30 watt complete.
Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed.
M&L, sub main wiring with two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and including non metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia confirming to IS 14930 (Part-I) 2001, with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed. (NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface.
All as per item above but for 2 single core PVC insulated unsheathed FRLSH 1.5 sqmm copper conductor wire drawn in and including 20 mm dia conduit pipe with one run of 1.5 sqmm PVC insulated unsheathed FRLSH copper conductor wire as earth contineuty conductor complete.
S&F in repairs of PVC rectangular block for mounting, switches, sockets, fan regulator etc, with 3 mm thick plastic laminated sheet cover of size 100x100 mm and 50 mm deep complete all as specified and directed.
All as per item No. 7 above but for size 175 x 100x 50 mm deep
S&F in repairs switch piano, flush button single pole one way 5 Amp complete all as specified and directed.
S&F in repairs switch piano, flush button single pole one way 15 Amp complete all as specified and directed.
Taking down unserviceable Sheet metal box & MCB DB SPN with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
Taking down unserviceable TPN DB with MCB's of any make/capacity, complete, all as specified and directed by Engr-In-Charge.
S&F sheet metal enclosure double door distribution board factory made for MCB DB load link VTPN 4 way suitable for MCCB as incomer, 100 Amp,4 pole & Including MCCB 100 amps 4 pole 16 KA complete. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking down all as directed by Engr-in-Charge at site.
S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR) type with blanking plates where required and IP 43 degree protection complete all as specified and directed.
S&F, MCB SPN 63 Amps, 240 volts 'C' series 16 KA ,including connection with suitable size copper lugs complete all as specified and directed.
S&F, MCB SP 240 volts, 63 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F, MCB SP 240 volts, 6 to 40 Amps, 'C' series 10 KA including connection with suitable size copper lugs. complete all as specified and directed.
S&F in repair / replacement of old unsv LED luminaire 600 mm x 600 mm 36 watt, 220 Volts, AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling incluing connecting upto drive with reqd length of not less than 1.0 Sqmm PVC multistranded BIS marked 03/02 core copper conductor for electrical connection to connector of LED fitting including testing on completion & Taking down old unsv fittings all as specified and directed.
S & F repair / replacement of old unsv security light fittings better optics for uniform distribution IP 65 protection LED of 30 watt, Heat resistance glass, pressure die cast aluminium housing including 25mm dia galvanised iron pipe light grade bracket bent to shape over all length 0.60mtr fixed to wall with 02 Nos FI clamps made of 40 x 5 mm FI, 15 cm long, 8 mm dia bolts and nuts with washers grouted in wall complete including reqd length of 1.5 Sqmm PVC multistranded BIS marked, 03 core copper conductor for connection from ceiling rose to light fittings incl testing on completion & Taking down old unsv fittings all as specified and directed.
M&L for bending & shaping of 25 mm dia galvanised iron pipe light grade over all length 0.60 mtr including necessary clamps, brackets and bolts mtr etc to fixed on wall/pole as per site requirement including fixing on pole with light fittings.
S & F PVC Three core copper conductor 2.5 Sqmm alongwith PVC pipe for protection from junction box to bracket complete .
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 4 Core Make of cables :- Polycab, Gloster, KEI.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 Core
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armured electric power cable (Heavy duty ) with aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 3.5 Core
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete.
Sand filling in trenches with clean dry unwashed sand free from sharp particles, gently punning around the cables complete.
Bricks, old size sub class `B' laid in trenches with width wise along the alignment of the cable as protection complete.
S&F tube 'Light' grade galvanised Pipe of 50 mm dia with all fitting for cable protection, laid in trenches, fixed to wall and floor by MS shaddle & fixed with pole, 02 position by MS clamp made of 40x5 mm MS flat, complete all as specified and directed.
M&L for cement concrete (1:3:6), type C-1, using 20 mm graded crushed stone aggregate for pedestal of poles/coping including necessary form work, fair finishes to the exposed surface using extra cement all as specified and directed
M&L Heating shrinkeable cable end joint kits indoor/outdoor type for LT cable of size 25 to 50 sqmm, XLPE armoured cable 4/3.5 core.
M&L for testing results of old earthing using calibrated earth tester & submitting result to engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour of 300 x 300 mm size and writing work for earth test result with date & year with white paint all as specified and directed at site by Engineer-in-Charge.
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test. Testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded BT stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded BT stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12 mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 15mm dia GI medium grade earth lead protection pipe including provn of earth test point made of 50 x 5 mm MS Flat in 'D' shape 500 mm legth grouted in wall complete 01 x 6 mm multistrand PVC insulated copper conductor ( Green Colour) to be provided from test point to DB through 20 mm dia concealed non metallic conduit complete all as specified and directed.
M/s raj construction
lodhi builders
M/s Pal Construction
M/s Anupam Construction Co.
OLIVE EXPORTS PVT LTD
BHAGIRATH CONSTRUCTION COMPANY
M/s Shanti Enterprises
M/s Sagar Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .