Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹50.4 L+₹1.2 L (2.40%)Rejected-Finance GUIJAN GAON WARD NO 3 C O RAJKHOWA HOUSE P O RANGAGORA DIST TINSUKIA ASSAM PIN 786147 | TINSUKIA | ASSAM | 786147 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹50.9 L+₹1.7 L (3.44%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹51.2 L+₹2.0 L (3.98%)Rejected-Finance A 153 HQ CE EC KOLKATA LEKHAPANI POST TINSUKIA DIST ASSAM STATE | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹51.6 L+₹2.3 L (4.71%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Sept 2024, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
SPECIAL REPAIR FOR EXISTING OLD VINTAGE FLOOR TILING OF ENTIRE HALL, LUGGAGE STORE OF BLDG NO P-9 AND SPECIAL REPAIR OF OR MD ACCN BLDG NO P-20 (1 TO 8) AT DINJAN MILITARY STATION UNDER GE DINJAN
2024_MES_667263_1
C/8704/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹90,000
Yes
4 Oct 2024
22 Jul 2024
25 Sept 2024
22 Jul 2024
18 Sept 2024
5 Aug 2024
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and directed.
M&L for plain cement concrete (1:4:8), type D2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposing the rubbish off the premises complete all as specified and as directed.
M&L for Non Skid ceramic coloured tiles 7mm to 8mm thick, premium quality conforming to IS-13755, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM(1:6) complete all as specified.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.36 Sqm, as in skirting etc. over 10 mm thick back coat of cement mortar in (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar in (1:6) for laying floor finishes complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in skirting etc. over 10 mm thick back coat of cement mortar in (1:4), set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 450X 300X 7 mm thick over 10 mm thick back coat of cement mortar in (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for machine cut Kota stone slab 20-22 mm thick in riser steps skirting dado and pillar laid over cement screed 15 mm thick CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and as directed by Engr-in-Charge.
M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, including 20 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
M&L for rendering 15 mm thick in cement mortar (1:6) other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of external surface of wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer (water proofing compound measured as separately) and finished even and smooth without using extra cement complete all as specified and directed.
M&L for 10 mm thick cement plaster in cement mortar (1:3) as on ceiling, finished even & smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of primer including wall care putty (minimum 1mm thick) complete all as specified and as directed.
M&L for preparing newly plastered surfaces of brickwork or previously untreated and applying two coats of oil bound distemper over a coat of alkali resistant priming paint over a coat of 1mm thick wall putty complete all as specified and as directed.
M&L for preparation of newly plastered surfaces or previously undecorated surface of external walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation old decorated plastered or unplastered surfaces of wall cornices etc by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moos, efflorescent, having oil and gresase spots and applying two coat of cement base paint (white or tinted) including necessary scaffolding complete all as specified and as directed
M&L for Complete removal of existing tretment and preparation of old decorated plastered surfaces of walls, cornices etc by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying two coat of white wash including necessary scaffolding complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in plinth protection, footpath, hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
Providing precast cement concrete louvers and jallies, type B0 (1:2:4) using 12.5 mm aggregate, 25 mm thick, set in CM (1:4) (measured solid), including all mouldings but excluding frame complete all as specified and as directed.
Taking down chowkats or frame exceeding 1.5 Sqm and not exceeding 4.00 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
S&F pressed steel frames for doors of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F pressed steel frames for doors of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F for solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, complete all as specified and as directed by Engr-in-Charge.
S&F 35 mm thick, second class hard wood, glazed and skeleton shutters with open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitered beads for securing glass, etc, sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a), complete all as specified and as directed.
M&L for 35mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats, sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and as directed.
S&F for powder coated aluminium frame for ventilator of size 65 x 38mm with anodised aluminium posh/pull glazed type shutter with glass and necessary jointing cleats glazing clips, rubber packing, anodized aluminium snap beading, screws, anodized aluminium handle, including supply and fixing of 4mm thick frosted sheet glass complete all as specified
S&F for 75mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed.
S&F for 150mm long aluminium, barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
S&F for 150 mm size, auminium handles, cast type, anodised to a bright natural, mat finish complete all as specified and as directed.
S&F for mild steel sliding door bolts, 250mm long, plate type, stove enamelled black, with bright bolts not less than 12mm dia with & including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate etc complete all as specified and as directed.
S&F for stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fixing framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings including guard bars, grating and holdfast etc, (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and conforming to Fe 410-W (Gde-E-250) Quality A complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for Joist, channel, angle, or tee sections, fixed independently, without connecting plate etc as in rafter and purlin etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Conforming to Fe-290 (Gde-E-165) complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chrome red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer including necessary scaffolding complete all as specified and as directed.
S&F in repairs curtain rails, Harrison rail, aluminium alloy with fixing brackets, stops, rollers etc complete all as specified and as directed.
Taking up or down 15mm bore existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and as directed.
Taking up or down 20mm bore existing steel tubing and connections including cleaning for refixing or removal to stores complete all as specified and as directed.
S&F for 20mm bore CPVC tubing med grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
S&F for 25mm bore CPVC tubing med grade with all fitting and fixed complete to walls and ceiling or laid in floors complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for Reinforced Cement Concrete 1:2:4, type B-1 (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed. (Note : reinforcement shall be measured and paid separately against respective item).
Use and waste form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed.
S&F for TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
M&L for mild steel TMT bars 6 to 8mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth complete all as specified and directed.
S&F in repair bib taps fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and as directed.
S&F in repair 15 mm bore, stop valves, cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repair 15 mm bore pillar taps, cast copper alloy, chromium plated, fancy type with capstan heads, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F in repairs brass chromium plated shower rose 125mm size with shower arm 15mm size 150mm long with bend, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs 20mm bore gun metal gate valve with iron wheel head, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs 50mm bore, high density poly-ethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed to wall, ceiling or in floors complete all as specified and as directed.
S&F in repairs 32/40 mm dia x 800mm long waste pipe for sink/wash basin/ urinal etc complete all as specified and directed.
S&F in repair 20 mm bore, brass chromium plated, tubular towel rail, D type, 60 cm long between flanges with brackets complete all as specified and as directed.
S&F in repairs, PVC low level flushing cistern, 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe and flush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed
S&F vitreous china Semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing including taking down the existing old one all as specified and as directed.
S&F in repairs vitreous china wash basin, size 550 x 400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.
S&F in repairs stainless steel kitchen, sinks made of 1 mm thick sheet for kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm and bowl size 410mmx330mmx160mm complete all as specified and directed.
S&F for stainless steel plate rack 1 mm thick racks of standard quality 900x900x250mm size complete all as specified and directed.
S&F in repairs 15 mm bore, stop valves, fancy type, cast copper alloy, chromium plated, with long shank and cup ( concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in repairs 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets and frame work any type complete all as specified and as directed.
M&L for 25 mm thick plain cement concrete, (1:2:4) type B-0 (12.5mm graded aggregate) mixed with approved WPC as per manufacturers instructions as in roof padding / Chajja, etc complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of distemper oil emulsion complete all as specified and as directed. Make of E-Board : Eternit Everest / Lafarge/ Armstrong/Visaka Industries Ltd.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below and as directed:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100m & n.exc.250m. (b) 15 mm thick plastering in cement mortar 1:4 finished even & smooth. (c) Preparing & cleaning of fully dried cement plastered surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 liters per sqm conforming IS-3384 (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm )shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm Note :- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
S&F 20 mm thick, second class hard wood boarding, clean sawn, planed one side with butt joints and fixed with nails in any situation as in eaves board, etc complete all as specified and directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight - 210 gms) complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed .
S&F in repairs 110mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F in repairs 75mm PVC (SWR) pipes single sockets, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends with acces any radius complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends with acces any radius complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends with acces any radius complete all as specified and as directed.
S&F for 110mm bore, PVC (SWR), reducers complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) junction single (Single T) equal or unequal with access door complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) vent cowl fixed with solvent cement complete all as specified and as directed.
S&F in repairs prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, including teakwood beading fixed with screws to timber frame work or fixed with hinges to steel and iron frame complete all as specified and as directed.
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing PVC/modular metal box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one, one way switches complete all as specified and as directed.
All as per item No 100 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 100 above but for one 5 Amps, 3 pin socket outlet on the same board with other switches.
All as per item No 100 above but for one light point controlled by two way switch.
All as per item No. 100 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specfied and as directed.
All as per item No. 100 above but wiring with cables of size 4 sqmm & cables of size 4 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specfied and as directed.
S&F for switch piano, flush type single pole, 230 volts, 5 Amp one way bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, 240V bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 5 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for bell push, flush type, 5 Amps 230 Volts, bearing ISI marked complete all as specified and as directed.
S&F for call bell, AC, 230 volts, single pole complete all as specified and as directed.
S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for stepped type (five steps), electronic fan regulator, flush type (socket type) complete all as specified and as directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED Lamp 9 Watt complete all as specified and as directed.
S&F LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, efficacy : 125 lm/W, complete all as specified and as directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S&F LED building security light fitting 35 Watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection and including all necessary items for installation complete all as specified and as directed.
S&F in repairs street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed.
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end bus bar, triple pole & neutral (TPN), 4 way, 415 Volts suitable for fixing MCBs including complete all as specified and as directed.
S&F in repair factory made board distribution (DB) double door in sheet metal enclosure with common bus bar at incomming end, single pole & neutral, 8 way, 240 Volts suitable for housing MCBs including complete all as specified and as directed.
S&F in repair 415 Volts 10 KA 'C' curve miniature circuit breaker, triple pole & neutral 63 Amps in the DB complete with connection testing and commissioning complete all as specified and as directed.
S & F in repair MCB, 'C' Series, SPN, 240 Volts, 40- 63 Amps, 10KA capacity complete all as specified and directed.
S&F in repair MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed.
S&F in repair MCB, Single pole and neutral , 240 Volts, 6 to 32 Amps, 'C' series, 10KA capacity breaking capacity complete all as specified and directed,
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete as specified and as directed.
Taking down unserviceable sub-main wiring up to 10 sqmm with rigid steel conduits/PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, armoured cable for working voltage of 1100 Volts, PVC insulated, armoured, nominal cross sectional area of main conductor 35 Sqmm, 3 core with reduced neutral conductor (3 1/2 Core), stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundation/cable trench, not exceeding 10Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning filling including spreading, levelling and well ramming in layers not exceeding 25cm thick in soil complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
M&L for bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and as directed.
Boring of holes horizontal for laying not less than 40mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
M&L for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor /road crossing /drain etc as in protection of UG cable complete to walls and ceilings or laid in floors including taking down old unserviceable complete all as specified and as directed.
M&L for steel water tubng 25mm bore, galvanised, medium grade with all fitting and fixture to be fixed to walls and ceilings or laid in floors, duly clamped all as directed and as specified
Taking down carefully MCB DBs any type, any capacity from main switch board/ cut out boxes and removing material to store for keeping in safe costody for reuse at site or for credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed.
Taking down carefully existing ceiling fan of any size/sweep/make from it's existing position, replacement of defective spare parts and re-assembling and refixing/hanging in the same position connecting with flexiable cable including testing complete all as specfied and as directed.
M/S. UDDUG CONSTRUCTION (BID ID -3098519)
M/S AUTOMOTIVE WORLD (BID ID -3098732)
R D Enterprises (BID ID -3097386)
M/s GANDHESWAR PHUKAN (BID ID -3097182)
M/S A K BROTHERS (BID ID -3098939)
M/S A K ENTERPRISE (BID ID -3098996)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .