Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹14.0 Cr
EMD Value
₹27.9 L
Closing Date
10 Nov 2026, 5:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Sekhar Nandal, Executive Engineer
Division - Road Maintenance and Urban Amenities
Upgradation of sector dividing road 99/102 (Asset ID 138), Gurugram
2026_HRY_554970_1
202642CCDE9B 0EE3 425C 806C 7E1AA077EE8E720001
Open Tender
Civil Works
Works
300 days
Gurugram
As per CBD
2 documents required · 2 mandatory
₹1,180
₹27.9 L
Yes
Plot No.3 sector-44, Gurugram
16 Oct 2026
16 Oct 2026
11 Nov 2026
16 Oct 2026
10 Nov 2026
16 Oct 2026
23 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | - Supply installation and Testing of IP - 67,LED flexi ble LED Strip light_ 36 W Havells Cat No: FLEXISTRIP 36 W or Equivalent to Philips or Wipro | 1,380 | Metre | 1 | ₹1,380 |
| - | SITC of highquality group control enabled integrated LED Street Light with a minimum system lumen of 19600 lm and system wattage 140W with a minimum system efficacy of 140 lumen/watt . The LED used shall have CCT of 5700K, SDCM must be less than or equal to 5 and CRI must be greater than or equal to 70. The housing should be made of LM6/ADC12 Alloy, non-corrosive Single Piece pressure diecast aluminum, to withstand extreme environments. The spigot shall be part of “Single Piece Pressure Die-cast housing” and shall not be bolted/welded/mechanically joined to the luminaire housing to ensure robust design. The luminaire shall have polycarbonate front cover/lens. The name of the brand should be embossed/engraved and should not be mentioned using sticker/screen printing. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. The luminaire LED shall have declared Lifetime of 75K hours@L70. Product should be designed for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP66 and impact resistance shall be IK10. Control gear compartments shall be Top maintainable without accessing/opening the optical compartment. The Luminaire should have a minimum 10 KV/5KA SPD duly bolted in the Luminaire. The SPD should be able to sustain a minimum 15 hits of 5KA rating i.e. Total of 45 hits across all the three modes as per IEEE 62.41.2. The luminaire should be of Class B Serviceability. The LED used in the luminaire shall be SMD type only and shall be from either, APT Electronics and CREE make or equivalent. The Driver should be asphalt potted and should be a BIS approved driver. The driver shall be replaceable. The driver shall have operating voltage of 120V to 270V, PF=0.95 @full load, THD=10% @ full load, In-built surge protection of 4KV. The driver should be capable of withstand voltage stress of 440V for 8 Hrs., should have an auto shutdown/cut-off at less than 90V and 325V(±15V) and have an auto recovery feature. The driver shall comply to IEC61547 and IEC 61000-3-2. The driver shall be EMI/EMC Complied as per EN55015/CISPR15. The luminaire shall be able to give Constant Light output (CLO) between voltage range of 140V to 277V. The luminaire driver and it’s SPD shall be of the same make/manufacturer/Lighting company as that of LED luminaires. Luminaire manufacturer must have Inhouse NABL accredited lab to conduct LM79, Type test as per IS10322, `FAT` before dispatch as per IS 10322 and IK Test. The detailed specifications shall be as per tender......... | 69 | Each | 1 | ₹69 |
| - | S/E of make Hot Dip Galvanized Bracket 1500mm overhang made off 3.25 thickness sheet 50mm dia (ID) M.S pipe welded to 450mm long Octagonal canopy with an angle of inclination of 105° the vertical the top end of canopy should be closed made of M.S sheet of 16 swg. 25mm dia M.S pipe 2mm thickness sheet should be welded diagonally at top side of bracket should be as per design attached double Arm Bracket). | 12 | Each | 1 | ₹12 |
| - | S/E of underground cable loose in existing pipe or trenches complete with n/connections. 25mmsq x 4 core (unarmored) | 1,504 | Metre | 1 | ₹1,504 |
| - | SITC of feeder Pillar/street Light Panel with 3phase/12KW Load/24Hr. Digital Timer/ 65TP Contactor/ 63 TPN MCB with all civil arrangement | 4 | Each | 1 | ₹4 |
| - | Supplying and laying of 1.5 sq.mm 3-core copper cable, including proper termination, fixing, connection, testing and commissioning with all necessary accessories such as lugs, glands, ferrules and insulation as required at site. | 1,504 | Metre | 1 | ₹1,504 |
| - | Providing and fixing 3 Nos. recycled plastic dustbins of 100 litre capacity each, in three different colours for dry, wet and recyclable waste, mounted on M.S. RHS 50 × 25 × 3 mm frames with M.S. SHS vertical supports, including base supports and grouting in 1:2:4 cement concrete of size 180 × 40 × 30 cm, complete with all materials, fabrication, fixing and accessories. Recycled plastic shall be durable, UV-resistant and suitable for outdoor use, conforming to relevant BIS specifications. | 22 | Each | 1 | ₹22 |
| 8 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, in two Nos. covers each of size 1000x450x100 mm, placed side by side along the 450 mm side in a single M.S. frame to cover a drain of 1000 mm length x 900 mm width overall, each cover reinforced with 8 mm dia four Nos. longitudinal and 9 Nos. cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mmx1.6 mm on each cover, and including providing one No. recessed M.S. lifting hook (loop) in each cover, anchored to the reinforcement, complete. The rates are including of drain covers, common M.S. frame, lifting hooks, steel, carriage, fixing complete in all aspect, as per satisfaction of Engineer-in-charge. | 114 | Each | 1 | ₹114 |
| 9 | Re-use of 80% of the existing WMM and GSB layer obtained after excavation of the existing carriageway. | 1 | Each | 1 | ₹1 |
| 10 | Providing and fixing a bench made of recycled plastic waste (recycled trash), of size 1800 mm length × 900 mm width × 450 mm seating height, with sides, seat and backrest made of recycled material, including necessary supports, fittings, spray painting/finishing with approved coating, and fixing by grouting in 1:2:4 cement concrete, complete with all materials, labour and fittings as per relevant BIS specifications. Minimum weight of each bench: | 16 | Each | 1 | ₹16 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
BOQ_634896.xls
BOQ • 0.34 MB
AD0182843.pdf
Additional Documents • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .