| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC | L1 | Accepted-AOC Lowest Tender | |
| 2 | L2₹26.8 L+₹2.3 L (9.28%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹27.1 L+₹2.5 L (10.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹27.5 L+₹2.9 L (11.9%)Rejected-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹27.6 L+₹3.0 L (12.3%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
27 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER (SOUTH) BANGALORE
GARRISON ENGINEER (SOUTH) BANGALORE NO 1, ULSOOR ROAD BANGALORE-560 042
AS PER BOQ AND TENDER DOCUMENT
2021_MES_465913_1
GS(S)/B/8525/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (SOUTH) BANGALORE
₹60,000
Yes
29 Dec 2021
6 Aug 2021
30 Aug 2021
6 Aug 2021
27 Aug 2021
22 Aug 2021
6 Aug 2021 - 13 Aug 2021
Amount
S&F ceiling fan complete with electronic type regulator and accessories 230 V, 1200mm sweep, BEE 5 star rated, ISI standards, RPM 340, Air Delivery 210CMM, including down rod, rust - free powder coated finish and pre-wired and including connecting up with twin core twisted flexible copper conductor cable with connector including dismatling old one and depositing to AGE E/M Store yard complete all as specified and directed. Make:- Bajaj Product code 250763 or equivalent in Crompton/Havells.
S&F exhaust fan 300mm metal body 1400 RPM single phase 230 volt air delivery 1300CMH including dismatling old one and depositing to AGE E/M Store yard complete all as specified and directed. Make:- Bajaj Product code 70046 or equivalent in Crompton/Havells.
S&F water heater storage type electric capacity 25 ltrs, BEE 5 star rated and pre-wired and including connecting up with three core copper conductor cable with 15Amps plug top including dismatling old one deposit to AGE E/M Store yard complete all as specified and directed. Make:- Bajaj Product code 150800/150756 or equivalent in Racold/Usha.
S&F PVC flexible Hot and cold connection pipe 450mm long for Geyser complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr in depth for taking up/down the GI strip and getting out in soft/loose soil complete all as specified and directed.
Returning filling in incl spreading, leveling watreing and well ramming in layers n exc 25cm each in soils complete all as specified and directed.
S&F air termination single pointed aluminium rod not less than 12mm dia and 300mm long incl fixing of GI base on epoxy insulators of suitable size to isolate from the roof and fixing of insulators on roof over the purlin using self tapping screws of suitable length or other means to make the roof leakage proof for fixing of air terminal rod and connecting with down/roof conductors complete all as directed.
S&F aluminium strip of size 25x3.15mm including epoxy/porcelain insulators of suitable size, distance between insulators not more than 1mtr including fixing screws washers etc complete for fixing on steel sheet roof/Clading over the steel purlin using self tapping screws of suitable length GI washers, rubber washers etc to make leakage proof complete all as specified and directed.
Material and labour for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screws end connected to existing aluminium/GI strips complete incl 3 Nos 8 mm dia 25mm long hex head screw and including 3 nos fixing of test point with sheet metal enclosure on insulators to isolate from the walls, fixing of insulators on wall using suitable size of screws washers, gutti .rawal plugs etc including making good to distrubded surfaces complete all as specified and directed.
S&F GI strip 32x6mm burried in ground complete all as specifeied and directed.
M&L for earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth plate not less than 2.25 Metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanished earth strip 25x4 mm by means of bolts, nuts check and washers of GI or steel all as shown in electrical plate No. 3 of SSR Pt -I connected to earthing test point all as specified or indicated including GI pipe 15 mm dia light grade for earth wire protection, necessary excavation, earth work in any type of soil, PCC (1:3:6) type C-1 (with 20mm graded stone aggregate),chamber and 50mm thick precast RCC (1:2:4) cover slab re-inforced with XPM Jalli including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion complete all as specified and as directed. Note:- GI strip after 7.5 mtrs shall be measured and paid seperatley.
Supply and lay 50mm bore galvanized iron tubing medium grade ISI marked with all fittings laid in trenches/ fixed on walls/floor/roof etc. complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in coping for poles etc., with necessary formwork complete all as specified and directed.
Varsha Enterprises
RAMSON TRADERS
GS TRADERS
RASI AND COMPANY
M.G. Enterprises
SRIRAM ELECTRICALS
RRK PROJECTS
ABHISHEK CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .