| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.2 LAccepted-AOC PINE DALE PINE MOUNT RIDGE SHILLONG 793001 | EAST KHASI HILLS | MEGHALAYA | 793001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.5 L+₹99,940 (6.45%)Rejected-Finance C O T ALI NEAR TRIPURA CASTLE ROAD CLEVE COLONY SHILLONG 793003 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793003 | L2 | Rejected-Finance Being L2 |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
6 Jan 2020, 6:00 pmClosed
GE Shillong
Garrison Engineer Shillong Division Shillong-793002
REPAIR MAINTENANCE OF AIR CONDITIONER REFRIGERATOR HEATIN PLANT SOLAR HEATERS INCLUDING DG SETS AND LAUNDRY PLANT AND ALLIED WORK SERVICES AT SHILLONG CANTT AREA UNDER GE SHILLONG
2019_MES_299814_1
GE/SHL/51 of 2019-20
Open Tender
Civil Works
Item Rate
180 days
Shillong
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Shillong
₹32,000
Yes
27 Jan 2020
21 Nov 2019
7 Jan 2020
21 Nov 2019
6 Jan 2020
6 Dec 2019
Amount
S&F in repair of sealed compressor rotary type of capacity 2TR suitable for window/split type air conditioner complete all as directed by Engineer-in-Charge.Make:- Carrier / Voltas/ LG
S&F in repair of sealed compressor rotary type of capacity 1.5TR suitable for window/split type air conditioner complete all as directed by Engineer-in-Charge.Make:- Carrier / Voltas/ LG/ Bluestar/ Hitachi
Supply only Relay, box type for 1.5/2.0 Ton capacity Split/Window type Ac complete all as directed by Engr-in-Charge. Make: DANFOSS/RANUTAL/ORSIO/INDFOSS.
Supply only Capacitor Running type, 45/55 mfd for window /Split type Ac 1.5/2.0 ton capacity complete all as directed by Engr-in-Charge. Make: CIVCON/SARDA/UNIVERSAL/HAVELLS
Supply only Starting capacitor, 80-120 mfd for window/Split type air conditioner 1.5/2.0 ton capacity complete all as directed by Engr-in-Charge. Make: CIVCON/ SARDA/ UNIVERSAL/ HAVELLS.
Supply only Fan blade with blower motor for window/split type AC 1.5/2.0 ton capacity complete all as directed by Engr-in-Charge. Make:LG/Voltas
Supply only Blower motor of suitable for 1.5/2.0 TR capacity Window/Split Type AC all as directed by Engr-in-Charge as in repairs. Make: NGEF/Kivon / Crompton Greaves / LG/Voltas/Carrier.
Supply only Rotary type knob for Window type AC complete all as directed by Engr-in-Charge. Make:LG/Voltas/Carrier/Carrier
Supply only Roller assembly for Split type AC , ISI marked complete all as directed by Engr-in-Charge.
Supply only Toggle switch for window/split type AC complete all as directed by Engr-in-Charge. Make: KAYCEE / L&T / Havells
Supply only Flaring nut for Split Type AC of size 1/2"/1/4"/5/8" complete all as directed by Engr-in-Charge.
Supply only Overload protector suitable for 1.5 / 2.0 TR window / Split type AC etc complete as specified and directed by Engr-in- Charge. Make:- Siemns / Crompton Greaves / Legrand / L&T.
Supply only Air filter suitable for 1.5/2.0 TR capacity Window/Split Type AC complete all as directed by Engr-in-Charge.Make: LG/Voltas/Carrier
Dismantling the outdoor and indoor unit of Split type air conditioner, 1.5 ton capacity after removing refrigerant pipe connection, electric wire connection including refixing in the same position after following repairs and complete servicing of machine complete all as directed by Engr-in-Charge :- (a) Repairs of the suction and discharge tube and cooling coil and replacement of heat resistive thermocol, tube for gas & liquid line. (b) De-scaling the complete refrigeration system with carbon tetra chloride solution, replacement of defective capillary tube, strainer and dryer unit of required size assembling the system, leakage test of the system by applying approximate head and vacuum up to (-) 75 Cm column of mercury. (c) Recharging of gas with suitable refrigerant as required and testing the cooling effect satisfactorily on full load after re-installation of air condition complete all as directed. Note : Refrigerant Gas shall be measured and paid separately as 'Supply only' items.
Supply only refrigerant gas suitable for refrigerator, deep freezer,Window ,Split type Acs etc. complete including testing the cooling effect satisfactorily on full load all as directed by Engineer-in-Charge. Make Moto : R22(Ac),134 A(Deep freezer) R12 (Refrigerator), R-410 A (AC), R-32
S&F in repair Panel Circuit Board (PCB) for 1.5 /2.0 TR Window/Split type AC complete all as directed by Engr-in-Charge. Make: LG/Samsung/Voltas
S&F in repair Remote circuit complete with remote device for 1.5/2.0 TR Window/Split type AC complete all as directed by Engr-in-Charge.Make: LG/Samsung/Voltas
S&F in repair PVC insulated & sheathed copper conductor 1100 volts grade 3 core, 4 Sqmm ISI marked for ACs & Refrigerators etc complete all as specified and as directed.
M&L for Servicing of 1.5TR split type AC of make:- LG/ Voltas/ Carrier/ Amtrex after removing electric wire connection & cleaning of Cooling coil, condenser coil, Filter, replacement of any unserviceable minor parts such as relay, capacitor , knobs etc. complete all as specified and directed by Engineer-in- Charge. Note :Payment of spare parts shall be made separately under relevant items.
M&L for Servicing of 1.5/2TR Window type AC of make:- LG/ Voltas/ Carrier/ Amtrex after removing electric wire connection & cleaning of Cooling coil, condenser coil, Filter, replacement of any unserviceable minor parts such as relay, capacitor , knobs etc. complete all as specified and directed by Engineer-in- Charge. Note :Payment of spare parts shall be made separately under relevant items.
S&F in repair Sheet metal enclosures with socket plug top & MCB single pole & neutral enclosure with a two pin & earth plug and socket complete with one single pole and neutral MCB -240 Volt- 20 Amps, 'C' series etc complete all as specified and as directed. Make: Havells Cat No: DHDPUSN020 or equivalent of L&T/ Legrand/Schneider.
Material and labour for sub main wiring with two single core 6.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 6.0 sqmm green colour as earth lead including PVC casing capping of suitable size complete all as specified and directed, including taking down unservicable one.(Note: two run of 6.0 sqmm cable , one run of earth wire of 6.0 sqmm and one run of PVC casing capping shall be measured as one length).Make- Cable- Finolex / RR cable / Havells / V K Industries PVC Casing Capping- Presto plast/Finolex/Kalinga.
Supply only Condenser unit complete for 1.5/2.0 TR Window/Split type AC complete all as directed by Engr-in-Charge. Make: LG/Voltas/Carrier
Supply only Evaporator unit complete for 1.5/2.0 TR Window/Split type AC etc complete all as specified and as directed by Engr-in-Charge. Make: LG/Voltas/Carrier
Supply only Capillary tube and strainner with filter complete for 1.5/2.0 TR window/split type AC etc complete all as specified and as directed.
Supply only Cooling coil complete with aluminium deep freezer chamber for refrigerator of any capacity etc complete all as specified and as directed. Make: Voltas/Blue Star
Dismantling sealed compressor unit after removing all electrical connection and cutting of refrigerant pipe from refrigerators of 300/310/315/410 Ltrs capacity including de-scaling the refrigeration system with carbon tetra chloride solution, replacement of defective capillary tube, strainer and dryer filter of required size, re-assembling the system including recharging of suitable refrigerant as required, including testing of the complete system complete all as directed by Engr-in-Charge. Note for item Nos 27 to 29:- Refrigerent gas shall be measured and paid separately under relevant items of these schedule.
All as per item No 27.00 here in above but for refrigerator of capacity 165 /180 ltrs etc complete all as specified and as directed.
All as per item No 27.00 here in above but for deep freezer of capacity 200/265 ltrs. etc complete all as specified and as directed.
Supply only Relay for refrigerator/deep freezer of various capacities etc complete all as specified and as directed by Engr-in-Charge. Make : Siemens/LG /Carrier/Bluestar.
Supply only Sealed compressor unit 1/6 HP capacity for refrigerator of capacity 180 ltrs, including sealing of the compressor with welding etc complete all as specified and as directed by Engr-in-Charge. Make : Siemens/LG /Carrier/Bluestar.
Supply only Sealed compressor unit 1/6 HP capacity for refrigerator / deep freezers of capacity 286/300/315/345 ltrs, including sealing of the compressor with welding etc complete all as specified and as directed by Engr-in-Charge. Make : Siemens / LG / Carrier / Bluestar.
Supply only Thermostat switch suitable for refrigerator / deep freezer of any capacity etc complete all as specified and as directed. Make: Blue Star/Voltas/Carrier
Supply only Cabinet lamp including lamp holder and push switch including connection with electric wires etc complete all as specified and as directed.
Supply only Door rubber gasket for refrigerator up to 320 Ltrs capacity etc complete all as specified and as directed.
Supply only Defrost timer for refrigerator/deep freezer any capacity etc complete all as specified and as directed. Make: Blue Star/Voltas/Godrej/Samsung
Supply only Bi-metal for refrigerator / deep freezer of any capacity etc complete all as specified and as directed.
Supply only Cooling coil with aluminium chamber for Freezer of Refrigerator upto 320 Ltrs complete all as specified and as diretced.
Supply only Defrost heater suitable for Refrigerator of any capacity etc complete all as specified and as directed.
Supply only Copper suction and discharge pipe for insulation suitable for AC 1.5/2.0 Ton etc complete all as specified and as directed by Engr-in-charge.
S&F in repair Heating element of capacity 1.5/2 KW for heating system etc complete all as specified and as directed.
S&F in repair Thermostat for heating system etc complete all as specified and as directed.
S&F in repair temperature gauge for heating system etc complete all as specified and as directed.
S&F in repair pre air filter of size 600 x 600 mm for heating system etc complete all as specified and directed.
S&F in repair pre air filter of size 300 x 600 mm for heating system etc complete all as specified and directed.
S&F in repair fine air filter of size 600 x 600 mm for heating system etc complete all as specified and directed.
S&F in repair fine air filter of size 300 x 600 mm for heating system etc complete all as specified and directed.
S&F in repair power contactor 3 pole 440 volts 32 Amps etc complete all as specified and directed. Make :- L&T / Siemens / Legrand
S&F in repair Strip heater of capacity 3 KW for heating plant etc complete all as specified and as directed.
S&Fin repair Pan type heating element of 3 KW capacity for heating plant etc complete all as specified and as directed
S&F in repair PVC drain pipe 25 mm bore, superior quality, fixed on wall / roof / floor with necessary PVC or Stainless steel clamp or hook etc complete all as specified
Repair, maintenance of Diesel driven Gen set by replacing unserviceable minor spare parts such as gaskets,nuts,bolts,washers and spring etc including oiling, greasing and Servicing of DG set by replacement of connected fast moving spare parts complete all as specified and directed for the following capacities of DG Sets:- (a)DG Set Kirloskar 200 KVA Kirloskar HQ 101 Area 024/ 6161-DG/ AL/11 Note :- (a) Cost of minor spare parts such as gaskets,nuts,bolts,washers and spring shall deemed to be included in the rate quoted by the tenderer. (b) Lathe work if required shall also deemed to be included in the rate quoted against these items. (c) Spare parts such as fast moving item shall be measured and paid separately under relevant items of this schedule as "Supply only" Items. (d) Repair/ maintenance, servicing and overhaulling shall be carried out by dealer / distributor of manufacturer's of DG Sets or their authorised agent. Approval for same shall be taken from Accepting officer before execution of any work.
© All as per item no. 53.00 here in above but of DG Set Kirloskar 180 KVA Kirloskar MH Pump House 024/6142-DG/AL/10
(d) All as per item no. 53.00 here in above but of DG Set Kirlosker 160 KVA Kirloskar SE Falls 024/6124-DG/AL/10
(e) All as per item no. 53.00 here in above but of DG Set Kirlosker 140 KVA Kirloskar MH pump House 024/6039-DG//95
(f) All as per item no. 53.00 here in above but of DG Set Cummins 125 KVA Kirloskar MH Power House 138012B-01813E
(g) All as per item no. 53.00 here in above but of DG Set Cummins 125 KVA Kirloskar 9 KVA Power House ( Exchange) SM No 138013B-0D08148
(h) All as per item no. 53.00 here in above but of DG Set Kirloskar 82.5 KVA Kirloskar Cant II ( Pump House) Engine No. 4118901/ 1421037 & Alternator No. ES3D014J141631
(j) All as per item no. 53.00 here in above but of All as per item no. 53.00 here in above but of DG Set Cummins 63 KVA Kirloskar 9 KVA Power House Signal centre SM No. 024/6098-DG/06 & 024/6112-DG/AG/05
(k) All as per item no. 53.00 here in above but of DG Set Kirloskar 63 KVA Greaves Cotton Kench's Trace SM No. 024/6112-DG/06 & 024//6112-DG/AL/06
(l) All as per item no. 53.00 here in above but of DG Set Crompton Greaves 63 KVA Kirloskar GE Shillong Office SM/ MES No 024/6143-DG/10 & 024/6143-DG/Al/10
(m) All as per item no. 53.00 here in above but of DG Set Kirloskar 40 KVA Kirloskar HRDC SM / MES NO. 024/6038-DG/10 & 024/6038-DG/AL/02
(n) All as per item no. 53.00 here in above but of DG Set Kirloskar 30 KVA Kirloskar Labasee line pump House SM/ MES NO. 024/6162-DG/11 & 024/6162-DG/AL/11
(o) All as per item no. 53.00 here in above but of DG Set Greaves Cotton 30 KVA Kirloskar SE Falls Engine No. 3/08031002/74 and alternator No. GIR30/4333H
(p) All as per item no. 53.00 here in above but of DG Set Kirloskar 20 KVA Kirloskar Butchery SM/ MES No. 137582A-01759E
(q) All as per item no. 53.00 here in above but of DG Set Kirloskar 10 KVA Kirloskar 'B' Camp House SM/ MES No. 158077A-01858E.
Repair/maintenance of existing control panel of DG set by replacing the connected items such as leads, copper wire, thimble , Analogue Ammeter, Analogue voltmeter,frequency meter etc along with other minor parts required for carrying out maintenance complete all as directed by Engineer in Charge. Note- Analogue Ammeter, Analogue Voltmeter and frequency meter shall be measured and paid separately as supply only items below and the cost of labour element only be deemed to be included in the rate quoted against these item.
Supply only Analogue Ammeter Class 1, 5 A, 3 phase. Make : L&T Cat Part No. WDS301FEV00 or equivalent model from make Siemens.
Supply only Analogue Voltmeter Class 1, 3 Ph. Make : L&T Cat Part No. WDS01FCA00 model from make Siemens.
Supply only Frequency meter single phase, Class 0.20.Make : L&T Cat Part No. WDS121FCF00 or equivalent make of Legrand / Seimns.
Repair / Overhauling of self starter assembly of any type / make / model including replacement of bearings, bushing, washer, bendix pinion, carbon bush etc complete all as required for proper functioning for the following capacities of DG sets etc complete all as specified and as directed by Engr-in-Charge:- (a) DG set 180 to 200 KVA Note:-(i) Make & SM No of DG Sets shall be as specified against item No 53.00 to 53.14 here-in-before. (ii) Repair works shall be carried out by dealer of DG Sets or their authorised agents.
(b) All as per item no. 55.00 here in above but of DG set 125 to 160 KVA
(c) All as per item no. 55.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 55.00 here in above but of DG set 30 to 40 KVA
Disconnecting the Exhaust Pipe Line with mufler of DG set from Exhaust Manifold of the Engine and removing the Unserviceable Asbestos Rope from the Exhaust Pipe, Cleaning the Exhaust Pipe and cutting the mufler removing all Carbon Particles Inside including wrapping of existing asbestos rope complete all as directed by Engr-in-charge for the following capacities of DG Sets:- (a) DG set 180 to 200 KVA
(b) All as per item no. 56.00 here in above but of DG set 125 to 160 KVA
(c) All as per item no. 56.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 56.00 here in above but of DG set 30 to 40 KVA
Dismantaling Radiator assembly from DG set Engine from inside and out side , Cleaning and Washing the Radiators & fins by Compressed Air with Chemical Water, removing all dust, etc. from the Radiator and Filling Coolant, re-assemble the same in Original Position with new gaskets, radiator connecting hoses and clamps complete all as directed by Engr-in-charge, for the following capacities DG Sets.- (a) DG set 180 to 200 KVA Note:- (i) Coolant shall be measured and paid seperatly under relevnt items of this schudule. (ii) Asbestos rope shall be measured and paid separately under relevant items of this schedule. (iii) Repair/ maint works shall be carried out by dealer of DG Sets or their authorised agents.. (iv) Make & SM No of DG Sets shall be as spesified against item No 53.00 to 53.14 here-in-before.
(b) All as per item no. 57.00 here in above but of DG set 125 to 160 KVA
(c) All as per item no. 57.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 57.00 here in above but of DG set 30 to 40 KVA
Disconnecting the fuel tank including Inlet/Outlet Connections of the following capacities of DG sets and cleaning the Tank properly and removing all dusts, mud, etc. and refixing the fuel tank and Inlet/Outlet Pipe connections in orginal position complete all as directed by Engr-in-charge.:- (a) DG set 180 to 200 KVA Note:- Repair / Maintenance shall be carried out by Manufacturer's of DG set or their authorised agents.
(b) All as per item no. 58.00 here in above but of DG set 125 to 160 KVA
(c) All as per item no. 58.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 58.00 here in above but of DG set 10 to 40 KVA
M&L for scraping of old painted surfaces from DG sets and preparation of old painted surfaces for repainting complete body of DG set including alternator, with one coat of superior quality synthetic enamel paint of existing colour for engine ,alternator ,base frame etc. by spray painting including writing SM / MES NO complete all as directed by Enginner -in- charge for DG set of following capacities :- (a) DG set 10 to 40 KVA KVA
(b) All as per item no. 59.00 here in above but of DG set 63 to 82.5 KVA
(C) All as per item no. 59.00 here in above but of DG set 125 to 160 KVA
Material and labour for rewinding of starter armature of DG sets with super enamelled copper winding wire complete for the following capacities of DG sets including taking out old unserviceable one etc complete all as specified and as directed :- (a) DG set 180 to 200 KVA Note:- (i) Repair/ maint works shall be carried out by Manufacturer's of DG Sets or their authorised agents.. (ii) Make & SM No of DG Sets shall be as spesified against item No 53.00 to 53.14 here-in-before.
(b) All as per item no. 60.00 here in above but of DG set 125 to 160 KVA
© All as per item no. 60.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 60.00 here in above but of DG set 10 to 40 KVA
Repair / over hauling of automatic/manual, Governor assembly of any make/type/model complete including calibration and replacement of spare parts as required to make the governor 100 % trouble free complete all as directed by Engr-in-Charge:- (a) DG set 180 to 200 KVA Note:- (i) Repair/ maint works shall be carried out by Manufacturer's of DG Sets or their authorised agents.. (ii) Make & SM No of DG Sets shall be as spesified against item No 53.00 to 53.14 here-in-before.
(b) All as per item no. 61.00 here in above but of DG set 125 to 160 KVA
(c) All as per item no. 61.00 here in above but of DG set 63 to 82.5 KVA
(d) All as per item no. 61.00 here in above but of DG set 10 to 40 KVA
Repair, Overhauling and Servicing of dynamo assembly of 12 volt capacity, of any make / type including rewinding of armature and field coil with super enamelled copper wire including replacement of bearing / bushing, carbon bush etc complete all as required to make dynamo 100% serviceable including taking down old unserviceable one etc complete all as directed by Engineer-in-Charge.Note :Payment of spare parts shall be made seperately under relevant items
Repair, Overhauling,and servicing of alternator for battery charger of 12 Volt caapcity of any make / type and rewinding of armature and field coil with super enamelled copper coil including replacement of old unserviceable bearing, bushing etc and make the alternator 100% serviceable etc complete all as directed by Engineer-in-Charge.Note :Payment of spare parts shall be made seperately under relevant items
S&F only Indicator lamp (AC / DC) LED type as per existing fittings etc complete all as specified and as directed. Make: Legrand /Semens/L&T
Supply only Current transformer coil range 300/5 A ,15 VA / Cl-1 etc complete all as specified and as directed. Make: Legrand/L&T/Semens
Repair/ servicing of alternator of any make/type/model including grinding/polishing of slip rings assembly cleaning and re-tensioning of carbon bush holder including replacement of carbon bush for the alternators of following DG Sets : - (a) DG set 125 to 200 KVA Note:- (i) Repair/ maint works shall be carried out by manufacturer's of DG Sets or their authorised agents.. (ii) Make & SM No of DG Sets shall be as specified against item No 53.00 to 53.14 here-in-before. Note: (iii) Cost of spare parts shall be made seperately under relevant items.
(b) All as per item no. 67.00 here in above but of DG set 40 to 82.5 KVA
(c) All as per item no. 67.00 here in above but of DG set 10 to 30 KVA
Taking out of defective automatic voltage regulator (AVR) of DG set (alternator side) and supply and fix New automatic voltage regulator (AVR) as per existing including necessary connection, testing and cable work etc complete all as specified and as directed by Engr-in-charge for the following capacities of DG Sets :- (a) DG set 160 to 200 KVA Note:- (i) Make & SM No of DG Sets shall be as specified against item No 53.00 to 53.14 here-in-before.
(b) All as per item no. 68.00 here in above but of DG set 30 to 120 KVA
Supply only the following spare parts required for DG set of capacity 180 / 200 KVA as specified against item No 53.00 to 53.14 here-in-before. (a) Piston Assembly. Part No F615320000
(b) All as per item no. 69.00 here in above but Piston Ring set. Part No F600571000
© All as per item no. 69.00 here in above but Linner Assembly. Part No F638210000
(d) All as per item no. 69.00 here in above but Gasket set. Part No F656670000
(e) All as per item no. 69.00 here in above but Head gasket . Part No F600726000
(f) All as per item no. 69.00 here in above but Main bearing. Part No M055400003
(g) All as per item no. 69.00 here in above but C R Bearing. Part No B055410003
(h) All as per item no. 69.00 here in above but Valve (inlet/Exhaust). Part No F600755000
(j) All as per item no. 69.00 here in above but Valve seat. Part No FM35902000/F635904000
(k) All as per item no. 69.00 here in above but Valve guide. Part No F600702000
(l) All as per item no. 69.00 here in above but Valve steam seal. Part No F600714000
(m) All as per item no. 69.00 here in above but Rear oil seal. Part No F600916000
(n) All as per item no. 69.00 here in above but Front oil seal. Part No F601616000
(o) All as per item no. 69.00 here in above but Hose pipe set
(p) All as per item no. 69.00 here in above but Hose clamp set
(q) All as per item no. 69.00 here in above but Flexible pipe set
® All as per item no. 69.00 here in above but Copper washer set. Part No F656660000
(s) All as per item no. 69.00 here in above but Push rod. Part No F600440000
(t) All as per item no. 69.00 here in above but Air filter set. Part No F672907000/F672908000
(u) All as per item no. 69.00 here in above but Diesel filter set. Part No4811710000
(v) All as per item no. 69.00 here in above but Oil filter set. Part No 0643610000
(w) All as per item no. 69.00 here in above but Thermostat valve. Part No 3913990000
(x) All as per item no. 69.00 here in above but Fan belt. Part No F637511000
(y) All as per item no. 69.00 here in above but Solonied switch. Part No F683810000
(z) All as per item no. 69.00 here in above but Oil temperature gauge. Part No F690803000
(aa) All as per item no. 69.00 here in above but Oil pressure gauge. Part No F6908110000
(ab) All as per item no. 69.00 here in above but High water temperature switch. Part No F690969000
(ac) All as per item no. 69.00 here in above but Thrust washer. Part No W006320003
(ad) All as per item no. 69.00 here in above but Linear ring
(ae) All as per item no. 69.00 here in above but Rocker lever assembly. Part No F600750000
(af) All as per item no. 69.00 here in above but Can bush. Part No F600140000
(ag) All as per item no. 69.00 here in above but Connecting Rod bush. Part No S055520703
Supply only the following spare parts for DG set of capapcity 63 to 160 KVA as specified against item No 53.00 to 53.14 here-in-before. (a) Piston Assembly. Part No F615320000/200710
(b) All as per item no. 70.00 here in above but Piston Ring set. Part No F600571000
© All as per item no. 70.00 here in above but Linner Assembly. Part No F638210000/BM98224
(d) All as per item no. 70.00 here in above but Gasket set. Part No F656670000/BM62431
(e) All as per item no. 70.00 here in above but 'O' ring kit/Liner O ring. Part No F656680000/215983/216879/181449
(f) All as per item no. 70.00 here in above but Head gasket. Part No F600726000/BM50745
(g) All as per item no. 70.00 here in above but Main bearing. Part No M055400003/3239990
(h) All as per item no. 70.00 here in above but C R Bearing. Part No B055410003/203670
(i) All as per item no. 70.00 here in above but Front oil seal. Part No F601616000/212227
(j) All as per item no. 70.00 here in above but Rear oil seal. Part No F600916000/211253
(k) All as per item no. 70.00 here in above but Valve (inlet/Exhaust). Part No F600755000/144911/150288
(l) All as per item no. 70.00 here in above but Valve seal Part No FM35902000/F635904000/69965
(m) All as per item no. 70.00 here in above but Valve guide. Part No F600702000/66890
(n) All as per item no. 70.00 here in above but Valve steam seal. Part No F600714000
(o) All as per item no. 70.00 here in above but Can bush. Part No F600140000/157870
(p) All as per item no. 70.00 here in above but Connecting Rod bush. Part No S055520703/43067
(q) All as per item no. 70.00 here in above but Thrust washer. Part No W006320003/157280
® All as per item no. 70.00 here in above butHose pipe Kit
(s) All as per item no. 70.00 here in above but Hose clamp set
(t) All as per item no. 70.00 here in above but Flexible pipe set
(u) All as per item no. 70.00 here in above but High pressure pipe set. Part No 6H00970000
(v) All as per item no. 70.00 here in above but Leak off pipe. Part No 6H112420000
(w) All as per item no. 70.00 here in above but Oil filter set. Part No 0643610000/LF516
(x) All as per item no. 70.00 here in above but Diesel filter set. Part No4811710000/FF5511
(y) All as per item no. 70.00 here in above but Air filter set. Part No F672907000/F672908000/4055279/4055280
(z) All as per item no. 70.00 here in above but Oil pressure gauge. Part No F6908110000/500109
(aa) All as per item no. 70.00 here in above but Oil temperature gauge. Part No F690803000/500410-A
(ab) All as per item no. 70.00 here in above but Fan belt. Part No F637511000/178611
Supply only the following spare parts for DG set of capapcity 10 to 40 KVA as specified against item No 53.00 to 53.14 here-in-before. (a) Flexible pipe set
(b) All as per item no. 71.00 here in above but High pressure pipe set. Part No. 6H00970000
(c) All as per item no. 71.00 here in above but Leak Off pipe. Part No. 6H112420000
(d) All as per item no. 71.00 here in above but Oil filter set. Part No. 4811710000
(e) All as per item no. 71.00 here in above but Diesel filter Set. Part No. 0643610000.
(f) All as per item no. 71.00 here in above but Air filter set. Part No. 6H411
(g) All as per item no. 71.00 here in above but Fan belt. Part No. 0605201000.
(h) All as per item no. 71.00 here in above but Belt tensioner. Part No. 6H05003000
(j) All as per item no. 71.00 here in above but Lube oil pump. Part No. 6H00410000
(k) All as per item no. 71.00 here in above but Exhaust blow. Part No. 6H0041000
(l) All as per item no. 71.00 here in above but Stop solenoid. Part No 6H23204000
(l) All as per item no. 71.00 here in above but Copper washer set. Part No. 6H06110000
Supply and filling Engine Oil (20 W 40) ISI marked suitable for smooth functioning of DG Set , ,etc complete all as specified and as directed. Make- Servo / Castrol / BPCL.
Supply only Coolant , ISI marked , etc complete all as specified and as directed by the Engineer in charge. Make- Fleet Guard or equivalent and approved by GE.
M/S AKC ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .