Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC KATHARA DIST BOKARO 829116 | KATHARA | BOKARO | JHARKHAND | 829116 | L1 | Accepted-AOC Accepted as L1 as per NIT | |
| 2 | L2₹8.0 L+₹34,438.54 (4.48%)Rejected-Finance | L2 | Rejected-Finance Rejected as L2 as per NIT | |
| 3 | L3₹9.1 L+₹1.4 L (18.0%)Rejected-Finance AT SAWANG GOMIA BOKARO JHARKHAND 829128 | BOKARO | BOKARO | JHARKHAND | 829128 | L3 | Rejected-Finance Rejected as L3 as per NIT | |
| 4 | Rejected-Technical AT JHIRKEY PO KATHARA DIST BOKARO JHARKHAND | KATHARA | BOKARO | JHARKHAND | 829116 | - | Rejected-Technical Rejected as per NIT | |
| 5 | Rejected-Technical AT PO JARANGDIH BOKARO | JARANGDIH | BOKARO | JHARKHAND | - | Rejected-Technical Rejected as per NIT |
Tender Value
₹9.0 L
EMD Value
₹11,300
Closing Date
3 Jun 2025, 4:00 pmClosed
Colliery Manager (M), Manager(F), P.E(EnM)
Colliery Manager (M),Manager(F),Project Engineer(EnM)
Repairing and maintenance including diversion , extension of 3.3KV over head line from jhirkey yadav basti to jhirkey river side and harijan tola to safique gali transformr and mustaque gali under kathara colliery for the period of one (01) year.
2025_CCL_336041_1
KTC/PE/EnM/25-26/11 date- 23.05.2025
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Office of the Project Officer, PE (EnM), Kathara C
Repairing and maintenance including diversion , extension of 3.3KV over head line from jhirkey yadav basti to jhirkey river side and harijan tola to safique gali transformr and mustaque gali under kathara colliery for the period of one (01) year.
6 documents required · 6 mandatory
₹11,300
Yes
8 Jul 2025
23 May 2025
4 Jun 2025
24 May 2025
3 Jun 2025
24 May 2025
24 May 2025 - 31 May 2025
Amount
Erection of metallic pole/steel tubular pole of length exceeding 10M but not exceeding 12 M in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc as required.
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as reauired.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. Details of cost for one set
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of a set of cross bracing FRLSame work for 11 KV/440 volt over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc (as per drawing) and painting with primer and finish paint as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc.
Erection of all aluminium / DOG conductor of 7/2.11mm to 7/3.00 diamter and above including binding etc as required = 2.5KMx0.394Kg=985kg. +2% sagging+2% binding=1024.40 kg
Dismantling of over head lines comprising of copper/ aluminium over head conductor, G.I wire, cross arms, insualtors etc. (a) DOG Conductor 140mtrx0.394/mtr=552Kg. (b) Pin Insulators 15 Nosx2 kg =30Kg. (c ) Disc Insulator 18 Nosx 6Kg=108 Kg. (D) Channel Bracket 60 mtrx7.14 kg=428.40 Kg (e) Total = 1118.40 Kg
Supplying and erection of cradle guard wire including binding etc as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Ssupplying and erection of 8 SWG earth wire (50mtrs/SPN
Total impact of GST for the purpose of CTC
M/S C POWER (BID ID -1157792)
SEMCO ENGINEERING WORKS (BID ID -1156307)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .