Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹4.8 L+₹1.8 L (59.0%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹5.0 L+₹2.0 L (66.8%)Rejected-Finance SADASHIV PHUGE NAGAR OPP SANDVIK FACTORY RADHIKA RESIDENCY F WING FLAT NO 7 PHUGEWADI PUNE 411 012 | PUNE | MAHARASHTRA | 411012 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
REPAIR/MAINT OF TOWER CLOCK AT MAIN BLDG, LIFT AT ARN AND MISC ITEMS AT OFFR MESS AT CME
2021_MES_425660_1
8183/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class E b(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹10,000
Yes
19 Apr 2021
25 Feb 2021
24 Mar 2021
25 Feb 2021
22 Mar 2021
9 Mar 2021
26 Feb 2021 - 8 Mar 2021
60 days
Amount
Disconnection & removing of all electrical/mechanical connection carefully of tower clock for repair and replacment of defective boxes, spare parts, servicing/overhauling of clock machine and gear motion including cutting, filling, grinding, turning & balancing driving shaft and adjusting the differences in all clocks with respect to each other and setting of correct time, incl labour and technician charges all as specified and dirrected by Engr-in-charge.
Servicing/overhauling of gear box including replacment of unsv parts of gear box, motor coupling, auxiliary gear box, gear box and motion work spindle coupling incl labour and technician charges etc all as specified and directed.
Supply and fixing tube light fitting 1x36 watt comprising of VPIT copper ballast, bipin holder, bipin holder stand incl tube rod of 36W etc all accessories pre wired fixed to wall/ceiling, screw and connecting three core 23/.0076mm flexible wire rubber insulated complete all as specifed and directed by Engr-in-charge.
Supply and fixing Retro LED tube light with fitting & fixture 20W complete with all accessories pre wired fixed to wall/ceiling, screw and connecting with three core 1 sqmm flexible wire rubber insulated complete all as specified and directed by Engr-in-Charge
Supply and fix LED bulb 9W incl taking down old u/s lamp of any type complete all as specified and directed by Engr-in-Charge
Hiring of lifter crane with cabin up to max height 25 to 30 metre high for fixing of outer dial of tower clock to all of four sides. Note : Necessary manpower like Electricial Technician, masonry work, drilling to stone, fixing of dial, all labour charges for outside work are included in quoted rate for this item.
Disconnecting the electric supply and opening of the front panel of the dish washing machine strictly as per the manufacturers instructions/guidelines for carrying out inspection of heating and conveyor mechanism for wahing of utensils. (skilled technicians from authorised dealer/companys rep to be employed), replacement of defective heating kit RE 8230020 (BK) & fixing of front panel and conveyor system after carrying out necessary repairs as above, testing & commissioning to the entrie satisfaction of Engr-in-Charge
Maintenance and servicing of Lifts once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as Digital line Monitoring, SMPS, Pin master PCB, battery, Fan, Upgraded UPS system & touch button PCB etc and greasing of bearings of Lifts as directed by engineer-in Charge. Note : i) Spares required for above maintenance will be measured and paid separately under relevant item. (ii) Servicing to be carried out as per manufacturers instruction
Lift of 08 Passangers (544 KG), Location : Viewers Gallery ARN CME Pune
Supply and fixing of Digital line monitoring-7UG0818-1CA20-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing lift part of SMPS S250-48V, 48V-5.2A-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing lift part of SMT330-15- Pin master PCB O/P=PMC-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing lift battery 12V-1.2AH-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing lift battery 12V-7AH-FP (Make- Exide) complete all as specified and directed by Engineer-in-Charge
Supply and fixing Fan 6" A2 Rexnord-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing Upgraded UPS system 1000VA 1100VA-FP complete all as specified and directed by Engineer-in-Charge
Supply and fixing Touch button PCB for glass LOP-Single-FP complete all as specified and directed by Engineer-in-Charge
metro electrical services
M/S kirpan Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .