Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | Rejected-Technical NO21 1ST LINK STREET NEHRU NAGAR KOTTIVAKKAM OMR CHENNAI 600 041 | CHENNAI | CHENNAI | TAMIL NADU | 600041 | - | Rejected-Technical The bidder was disqualified, Since the bidder was uploaded price bid in place of Part -I Technical bid and forms in CPP Portal. | |
| 3 | Not Admitted-Finance | - | Not Admitted-Finance Others-The bidder was disqualified on account of not meeting the bidding capacity and non submission of solvency certificate as stipulated in NIT. |
Tender Value
₹24.1 L
EMD Value
₹48,200
Closing Date
19 Dec 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer, CEG, GSO
GSO Annex building, Kalpakkam - 603102
Construction of MRPU temporary office Phase 2 at DAE nodal centre Pallavaram, Chennai.
2024_GSO_837955_1
GSO/CTC/CEG/142/2024
Open Tender
Civil Works - Buildings
Item Rate
45 days
Chennai
As stipulated in NIT
8 documents required · 8 mandatory
₹0
₹48,200
7 Feb 2025
6 Dec 2024
20 Dec 2024
6 Dec 2024
19 Dec 2024
13 Dec 2024
7 Dec 2024 - 11 Dec 2024
Amount
All kinds of soil upto 1.50mtr depth
Supplying and filling in basement and foundation with sand including conveyance by lorry load, filling in layers of not more than 150mm in depth, each layer shall be well consolidated including watering, and dressing, levelling and dressing the top surface, etc., all complete as per standard specifications and as directed by Engineer- in-Charge.
Area cleaning in and around the site by cleaning the bushes, debris, fallen trees, waste materials, garbages etc., collecting, conveying and disposing the same at places as shown by the department with in a lead of 100metres, etc., all complete as per specifications and as directed.
Providing and laying in position of plain cement concrete using hard granite broken stone in foundations, trenches etc. including mechanical mixing, ramming, compaction, leveling, curing, dewatering, if any including the cost of formwork etc., all complete as per specifications.
1 : 4 : 8 (1 cement : 4 sand : 8 graded stone aggregate 20mm nominal size)
Providing, erecting, placing in position and removing Formwork for all insitu concrete works at all lifts and all shapes such as circular works, chamfers, splays, etc., using Steel / Plywood shuttering including centering, scaffolding, strutting, propping with necessary bracing in all areas, fixing of EPs, cutting holes and fixing pipe sleeves, applying of approved form oil over surface in contact with concrete, de-shuttering after specified curing period, etc., all complete as per drawings and specifications. [Note : Measurement for the formwork shall be the area of forms in contact with concrete surfaces. Stop boards for construction joints will not be measured seperately for payment. Centering and shuttering where exceeding 3.5m height in one floor shall be measured and paid for seperately.]
For Plain Surfaces upto 3.5m Lvl
Providing and casting insitu Reinforced Cement Concrete of the following grades of design mix by Weigh batching using machine crushed hard broken granite stone of nominal size 20mm including cost of admixtures in recommended proportion wherever required, mechanical mixing, transporting, placing at all lifts, vibrating, consolidation, curing, finishing smooth all exposed faces, for all insitu concrete items, etc., as per drawings and specifications. Note : 1) The rate quoted shall be exclusive of reinforcement and formwork which will be paid for separately under relevant items. 2) The rate of concrete shall include the cost of admixture in recommended proportions as per IS 9103 as per direction of Engineer-in-charge. 3) Cement proportion for Concrete Mix shall be on the basis of weigh batching only as per design mix. 4) The cost towards any upward / downward variation required to obtain the specified strength over the minimum cement content will be paid for or deducted at the rate specified in Schedule 'F'.
M 30 Grade Concrete (The Cement content considered is 370 Kg per Cu.m) - Upto FFL
Providing, cutting, bending, placing and binding Steel reinforcement using TMT bars of Fe-500D grade in all reinforced cement concrete works including cutting, bending, fixing, tieing in position with 1.6 mm dia soft drawn annealed binding wire, cost of cover blocks in C.M 1:2, etc., complete as per specifications and drawings. Important Note: The required quantity of steel reinforcement as mentioned in the schedule should be procured by the contractor only of SAIL, Rashtriya Ispat Nigam Limited (VIZAG), TATA Steel & JINDAL from authorised dealers which shall conform to IS: 1786 (Latest Edition).
Providing and constructing brick masonry at all lifts using approved well cured flyash bricks (made as per IS 12894 or latest edition) in cement mortar 1:5 using crushed stone sand. (Flyash+crushed stone sand+ lime+ additve/cement with waterproofing chemicals and accelerators) (non modular of class designation 5.0 ) with mortar in the ratio 1:1:4, where 1 part of flyash(IS 3812 or latest), 1 part of cement (IS 269 latest) and 4 parts of fine aggregate(IS 2116 latest), including suitable scaffolding, raking out joints, curing complete as per specifications and drawings for foundation, superstructure, etc. for the following floors.
Supplying, fitting, fixing in position of 5mm thickness Tinted glass of approved colour of "Saint Gobain" or approved equivalent make for doors, partition, windows, fixed glazing, louvers, etc., including fixing with putty, TW beading, Neoprene gasket, etc., all complete as per drawing and specifications.
Providing and fixing in position Aluminium partitions, doors, windows, ventilators, louvers, fixed glazing, sliding windows north light glazing, sliding shutter 'E' Channel, trellis, etc., using heavy duty standard anodized aluminium extruded sections, anodized aluminium sheets as per relevant IS code of "JINDAL" or approved equivalent make including pivots, approved door and window handles, door stopper, EPDM gasket, neoprene gasket lining, stainless steel screw, mastic filling, weather strips, washers, reinforcing the door shutters at top and bottom with MS rod threaded and fixed to vertical members, etc., as required and as per drawing etc., all complete at all heights and as directed by the Engineer in charge. NOTE:- 1. Payment shall be made on the basis of weight of aluminium members/section fabricated and actually installed in position without extra allowance for wastage no extra payment shall be made for non-aluminium consumable items like screws, gasket, weather strips PVC/Neoprene lining, sliding wheels for windows, in built tower bolt, reinforcing rods, etc., 2. Glazing, particle boards, Aluminium grills, mesh etc., will be paid separately under relevant items. 3. All fittings except under Note-1 will be paid seperately under relevant item and the fittings shall be of matching colour anodized aluminium sections. 4. The aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required cleat angles at no extra cost. 5. The aluminium section shall be anodized with "MATT FINISH" (15 micron thick) finishing and of approved shade / colour with the approval of Engineer-In-Charge.
Supplying, fabricating and fixing of EPs, Structural Steel work and pipe sleeves etc., at all lifts comprising MS angles, MS plates, tees flats, rounds, squares, other structural steel sections, pipe sleeves and pipes of various sizes, IS channels, IS beams, square rods, etc., of TATA or SAIL or approved equivalent make including cutting, welding, bending to shape, painting exposed faces with two coats of anti-corrosive paint of approved colour over a coat of zinc chromate primer / zinc phosphate primer, embedding with Cement concrete, etc. complete all as per specifications and drawings. Note: The rate shall be inclusive of lifting arrangements if any required to hoist and concrete embedment's for fixing the steel works.
Supplying, fabricating and fixing Steel work welded in built up sections and framed work at all lifts comprising Chequered plates, MS angles, other structural steel sections, etc., of TATA or SAIL or approved equivalent make including cutting, welding, bending to shape, painting exposed faces with two coats of anti-corrosive paint of approved colour over a coat of zinc chromate primer / zinc phosphate primer, embedding with Cement concrete, if necessary, etc., all complete as per specifications and drawings. [Note: The rate shall be inclusive of lifting arrangements if any required to hoist and concrete embedment's for fixing the steel works. ]
In Stair case, Trench cover, base plate etc., using of 6 mm thick or more plain/chequered plates wherever required.
Supplying, fabricating and fixing Steel Grills of required pattern and size for Windows/Ventilators, Staircase Hand Rails, etc., fixed to openings/wooden frames at site, comprising of MS square bars / MS rounds / MS flats, etc., including fixing with necessary wood screws for fixing grills / by welding in steel windows, painting with two coats of anti corrosive paint of approved colour and make over a coat of red oxide zinc chromate primer/ zinc phosphate primer, etc., all completed as per specification. [Note: The rate shall be inclusive of lifting arrangements if any required to hoist and concrete embedment's for fixing the steel works.].
Supplying, fabricating and fixing Structural Steel work in built up sections for gate, handrailing, trusses and framed work at all lifts comprising square / rectangular / Tubular hollow sections conforming to relevant IS standard of TATA or SAIL or approved equivalent make including cutting, welding, bending to required shape for curved profile, hoisting, fixing in position at all lifts, embedding with cement concrete, painting the exposed faces with 2 coats of metal coat PU finish paint of make MRF or other approved make over one coat of epoxy zinc phosphate primer with thinner 1110 Ep for epoxy primer and thinner for finish for metal coat paint as per manufacturer instructions, etc., all complete as per specifications and drawings. [Note: The rate shall be inclusive of lifting arrangements if any required to hoist, concrete embedment's and foundation bolts for fixing the steel works.]
Supplying, fabricating and fixing of Foundation bolts for fixing truss/column made up of MS/TMT bars of approved dia. including cutting, bending to required shape, making thread of required pitch, providing suitable bolt, embedding in RCC using templates, fixing the bolts, painting the entire bolt with two coats of anti-corrosive paint of approved colour over a coat of red oxide zinc chromate primer / zinc phosphate primer as per manufacturer instructions, etc., all complete as per specifications and as directed by the Engineer-in-charge.
Replacing the damaged existing mesh by providing and fixing Fly proof Stainless Steel (Grade 304) wire gauze of 0.4mm dia wire and 1.4mm aperture on both sides of approved quality and make over partly panelled Door / Grill door including removing the damaged mesh, fixing the new mesh with second class Teak wood beading or Aluminium frame work, cost of screws, nails, rawl plug, etc., all complete as per specification. [Note: Cost of frame work i.e., Steel or wood or aluminium, will be paid for separately under relevant item]
Providing 31mm thick red oxide flooring, under layer of 25mm. thick C.C. (1:2:4) with 12mm size granite chips and top layer of 6mm thick plaster cement red oxide mix, using 3.5kg of red oxide per 50kg of cement 1:3 finished with a floating coat of cement and oxide mix of same proportion etc., all complete as per specification.
Providing and laying first quality Jointless Polished Vitrified tiles of 600 x 600mm sizes with water absorptions less than 0.08% conforming to IS: 15622 of JOHNSON (Marbonite-PVT-DC) or KAJARIA (PVT-DC) or other approved make for flooring and skirting in all colours, shades and design of approved pattern including setting over base layer of 20mm thick in cement mortar 1:4, jointing with grey cement slurry @ 3.3 kg per sqm or by using tile adhesive of approved make, grouting the joints with epoxy based joint filling material or other equivalent jointing materials, curing, cleaning the surface with acid wash etc., all complete as per specification and as directed by Engineer in charge. (Note:- The sample shall be got approved by the Engineer-in-charge before making bulk order)
Providing and fixing PUF insulated sandwich wall panels of Kingspan Jindal or equivalent for walls of total thickness not less than 50mm & density 40 kg/cum( ± 2 Kgs). Both sides of the panels shall be coverd with min. 0.5mm thick galvanized steel skin sandwiching the rigid self extinguising type and CFC free polyurethane foam. The Precoated sheet shall be of minimum 240 Mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of 120 gsm as per IS:277 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron. The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches wihile trasportation. The panels shall prevent heat transfer from outside to inside and should be joined with built in cam lock system with narrow vertical gap between panel joints which has to be sealed with suitable silicone sealant for leak proof joints. Pop rivets and bolts shall be used at the time of erecting the structure. The GI/MS perimeter channels of 1.6mm minimum thickness for installation of panels shall be provided as required. Wall panels shall be also provided with openings & MS/GI section provisions for installation of windows, doors, ventillator, exhaust fan etc. as directed by the Engineer- in- charge.Window openings shall be provided with GI sunshade of min.600mm width & length as required, as directed by the Engineer-in-charge.
Rate shall be inclusive of all the complete accesories including GI/MS perimeter channel,bolts, screws , welding,sealant etc., required for the installation of wall panel and as directed by the Engineer-in-charge. Payment will be done based on the net area of the wall panels installed. The rate shall be inclusive of all fabrication charges, erection charges, transporting to site, taxes, labour charges, cost of fixtures, necessary fasteners, bolts, screws, hoisting mechanism painting and other finishes etc., complete as per requirement and as directed by the Engineer-in-charge.
Providing & fixing PUF insulated Roof Sheet: Providing and fixing PUF Insulated continuous sandwich panels of make Kingspan Jindal/ Suchi Foam for roofs of total thickness not less than 50 mm. Panel shall have min.0.35 mm thick pre coated GI sheet on both side of Polyurethane foam with external face being corrugated in shape for GI and PU foam both material. The Precoated sheet shall be of minimum 240 mpa steel grade confirming to IS 14246:1995 and shall have zinc coating of 120 gsm as per IS:277 , 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 micron.The PPGI Sheet shall have protective guard film of minimum 25 microns to avoid scratches wihile trasportation.The roof panels are laid over a frame work of trusses, columns and purlins fixed using 90mm self drilling bolt with rubber washer including all types of flashings. GI roof gutter of min. width 200mm & height 250mm shall be also provided on the corridor side of the roof with required supports along with min 75mm dia PVC downpipe as directed by the EIC.PU Foam must be self-extinguishing, fire retardant type having minimum density of 40 Kg/Cu( ± 2 Kgs) including 0.25mm craft paper edging,self tapping screws of required length and nos. including Roof accessories like End Cap, Rake Trim, External Crimped Ridge, Internal Ridge etc to be made from 0.5mm thick GI Sheet duly powder coated from both side etc. complete as per structural design and direction of Engineer-in-charge. The rate shall be inclusive of all fabrication charges, erection charges, transporting to site, taxes, labour charges , cost of fixtures, necessary fasteners, bolts, screws, hoisting mechanism painting and other finishes etc., complete as per requirement and as directed by the Engineer-in-charge.
Providing & fixing doors made of min. 40mm thick PUF panel. Door Frame shall be of MS T section 50x30mm size welded in position and shall have matching grooves/slots for fixtures. Door Shutter/Panel shall be provided with 50x25x3mm MS Channel alround and 2mmx200mm MS Plate at Lockrail. The door shall be provided with tower bolt for each shutters & min. 3 nos of ISI marked SS hinges. Rate shall be inclusive of MS door frame,channel & all fixtures as specified above. Only the rate of the door accessories such as lock, door closer & stopper will be paid separately under relevant items.
Providing plastering to the external surfaces of brickwork/concrete at all elevations in cement mortar 1:5, 20mm thick in two coats including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications. [Note: 6mm premium glass fibre of make Dugar & Co or Recron shall be mixed with Cement @ 60 gms of glass fibre per 50kgs of cement]
Supplying and installtion of PVC False ceiling Tiles 2500 x 250 x 6mm or approved size of make Sintex or approved equivalent make, with an air gap of minimum 4mm and joined together by tongue and groove using self tapping screws. The rate shall be inclusive of the cost of perimeter angles, screws and all other accesories required for the complete installtion of the false ceiling.
Providing and fixing Al hanging Heavy Quality floor door stopper ISI marked with Twin Rubber stoppers, anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to req. colour or shade with necessary screws etc. complete all as per specification and as directed by the Engineer-in -Charge. Sample to be approved by the Engineer-in-Charge.
Providing and fixing in position universal Hydraulic door closer bearing ISI mark of EVERITE/GODREJ or approved equivalent make as per IS:3564 (Type-B No.2) including fixing as per specifications.
Providing and fixing in position of built in Mortice lock with pair of Key and pair of brass lever handle of make "GODREJ" or approved make for aluminium / flush doors including cutting the frame and fixing with necessary screw etc., complete all as directed by Engineer-In-Charge.
Dismantling Plain cement concrete/Brick bat coba at all lifts including clearing and depositing the same with a distance of 100 metres as directed by Engineer-in-charge.
Electrical Items Supply, transportation, installation, testing and Commissioning of the following types of Battens. (Refer Sec VI, Clause No.16.1). - Catalogue No : BN308C LED20S-6500 L120 PSU WH or equivalent and Lamp Type LED.
Supply, transportation, installation, testing and Commissioning of the following type of Wall (surface) mounted luminaires. (Refer Sec VI, Clause No.16.1). - Catalogue No : WT202W LED6S CW PSU S2 PC or equivalent and Lamp Type LED.
Supply, installation, testing and commissioning of the following sizes of Metal Clad Socket in sheet steel enclosure with Plugs and Socket as per the detailed specification. (MS item will be measured separately). (Refer Sec VI, Clause No.15.4).
1 Phase, 20A MC socket box with 20A DP MCB
Supply and fixing following Modular front cover plate on existing modular metal/plastic boxes etc. as required. (Refer Sec VI, Clause No.15.7).
One/Two module
Supply Installation testing and commissioning of the following MCB on Distribution Boards as per the detailed specification. (Refer Sec VI, Clause No.14.2).
6-32 Amps SP MCB (Type-C)
Supply and Installation of following sizes of Surface Mounting Plastic Boxes as per the detailed specification. (Refer Sec VI, Clause No.15.6).
Surface Mounting Plastic Boxes 1/2 Module
Surface Mounting Plastic Boxes 3 Module
Surface Mounting Plastic Boxes 6 Module
Surface Mounting Plastic Boxes 12 Module
Supply and external installation of following sizes of Heavy Duty, PVC circular rigid Conduits for Electrical & Communication System with required Solid Long Bends, Couplings, GI Wire etc, as per the detailed specification.(Refer Sec VI, Clause No.27).
25mm Dia, 2mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes
32mm Dia, 2mm wall thickness PVC heavy duty round rigid conduits with 50mm deep Junction boxes
Wiring for lights / fans /sensors/ Timer /Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, switches/ sockets, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
Wiring for Power Points with 2 Runs of 4.0 Sq.mm Copper wires for Phase, Neutral and 1 Run of 2.5 Sq.mm Copper wires for Earth from MCB Distribution Board to Single Phase Metal Clad Socket.
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including 16A modular switch, 6/16 Amps combined shuttered type Socket and 10A modular switch & 3 pin, 6A shuttered type Socket, 1 no. 6M Modular Plate.
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase, Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including supply of modular plate, one No. of 16A modular switch & one No. of 6/16 Amps combined shuttered type Socket and Three Numbers of 10A modular switch & Three numbers of 3 pin, 6A shuttered type Socket, 1 no. 12 Modular plate.
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 16A modular switch, 6/16 Amps combined shuttered type Socket, 3Modular plate 1No.
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from Control Switch Box to control switch box including 10A modular switch & 3 pin 6A, shuttered type Socket and 16A modular switch & 6/16A combined shuttered type Socket, Modular plate
Wiring for Power point with 3 Runs of 2.5 Sq.mm Copper wires for Phase & Neutral and Earth from Control Switch Box to control switch box including supply of 16A modular switch, 3 pin 6/16 A combined shuttered type Socket, Modular plate.
Wiring for Light/Sensor/Fan Points with 2 Runs of 1.5 Sq.mm copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm copper wire for Earth from MCB Distribution Board to Primary light/sensor/fan point through Control Switch Box including 10Amps modular switch.
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to switch box and further to Light point including 1 No 10A modular switch
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch box to Light point/Ceiling fan including 1 No 10A modular switch
Wiring for Light point with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Light point to Light point /sensor/contactor
Wiring for Exhaust fan point up to 3Mtr height with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from MCB Distribution Board to Power point through Control Switch Box including supply of 3 pin 6A shuttered type Socket, 2Nos. 2 Modular plate and 1 No 10A modular switch.
Wiring for Exhaust fan point up to 3Mtr height with 2 Runs of 1.5 Sq.mm Copper wires for Phase & Neutral and 1 Run of 2.5 Sq.mm Copper wire for Earth from Switch board to Power point including supply of 3 pin 6A shuttered type Socket, 2Nos. 2 Modular plate and 1 No 10A modular switch.
Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm (14/0.3) PVC insulated & FRLS sheathed copper flexible cable of required length as per the detailed specification. (Refer Sec VI, Clause No.17.2).
150 mm sweep, Exhaust Fans with Automatic Front Louvers with shutters, Make:Usha or equivalent; Model: Crisp Air Premia AS Plus or equivalent
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11).
MS fabrication 1 coat primer & 2 coats synthetic enamel paint
Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29)
25 X 12 mm size of PVC Mini trunking
Supply, installation, testing and commissioning of following sizes of Wall Mounting Fans as per the detailed specification.. (Refer Sec VI, Clause No.17.4).
450 mm Dia. wall Mounting fan
Loading, Transportation, Unloading at site, Laying, Testing and Commissioning of one number PVC/HRPVC/XLPE insulated and PVC sheathed Stranded Aluminium/copper conductor power cable of 1.1 KV grade of following sizes direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required (Note: Cable will be issued free of cost by the department).(Refer Sec VI, Clause No.3)
3/3.5/4 Core X upto 25 Sqmm
End Termination of the following sizes of Aluminium Conductor PVC Insulated and sheathed armoured UG Cable using Single Compression, Heavy Duty, Gland connecting the cable to the equipment such as Switches/Panel Boards etc. using Comet or equivalent make Aluminium crimping lugs as directed by Engineer-in-Charge. The rate shall include the cost of supply of Cable Gland and Lugs. The Contractor shall arrange for making holes wherever necessary for fixing cable gland. (Refer Sec VI, Clause No.10.1).
4 Core X10sqmm
AC Item Supply and installation of 2.0TR Split type Air-conditioners with minimum ISEER value (Wh/Wh) shall be 3.8 and confirming to IS:1391 (Part-2) with latest amendments. Air-conditioners capable of performing; Cooling, Dehumidifying, Air Circulation & Filtering. Note: The inter connecting copper tubes with insulation and power cable of min. 4mtr to be supplied with this AC units.
Supply and Installation of a set of Hot gas & Liquid line copper piping along with thermal insulation and 3 core, 2.5 mm2, 1100V multi strand flexible FRLS PVC copper cable to interconnect indoor and outdoor units of the above 1.5/2.0TR Split Air conditioners as per the specification given in the scope of work. It also includes supply of copper tubes, thermal insulation over the copper pipe lines, brass flare nuts at both ends.
Supply and installation of 25mm heavy duty Insulated HDPE pipe to drain out condensate water from IDU.
Supply and installation of 2 mm thick MS power coated stand for mounting outdoor units.
LAN Works Supply and Installation of Cat 6 UTP cables etc., all complete as per specification.
Supply and Installation of 24 port Rack mountable Cat6 Patch Panel with CAT6 Jacks etc., all complete as per specification.
Supply and Installation of Single I/O box with faceplate and CAT 6 jack etc., all complete as per specification.
Supply and Installation of Dual I/O box with faceplate and CAT 6 jack etc., all complete as per specification.
Supply and Installation of 1 meter patch cord UTP CAT 6
Supply and Installation of 3 meter patch cord UTP CAT 6 etc., all complete as per specification.
Supply and Installation of 9 U wall mount Network Rack with PDU etc., all complete as per specification.
Telephone Items Supply, Loading, Transportation,Unloading at site, installation, Testing and Commissioning of one number of armoured Telephone cable of following sizes in direct in ground including excavation, sand cushioning, protective covering with chamber burnt/cement bricks on sides & top, refilling the trench and providing RCC route indicator etc as required. (Refer Sec VI, Clause No.3 & section V)
20 Pairs 0.63mm PIJF telephone cable.
Supply and installation of following sizes of HDPE Pipes Direct in Ground.
Supply and installation of PLB 40/33mm HDPE Ducts including excavation for routing of Power /Telephone Cables as per the detailed specification.(Refer Sec VI, Clause No.4.1 & 4.2).
Wiring and termination for Telephone point with 1 Run of 0.6 mm dia, 250 V grade PVC insulated, twin twisted, Two pair, tinned copper wire from Telephone Junction Box to Telephone points in concealed conduit/ PVC Trunking including of supply of Telephone wire. (Refer Sec VI, Clause No.18)
Wiring with 1 Run of Twin twisted, Two pair (0.6mm dia.).
Supply and installation of two modular box with two modular plates suitable for fixing telephone socket of reputed brand. (Sec VI, Clause No.15.6 & 15.7).
Supply and Installation of RJ-11 socket 1 Gang with shutter for information outlet and termination of 1 Run of data Cable.
Supply and Installation of following sizes of PVC trunking (casing & capping) on walls/Ceiling for routing of Power, Lighting and Telephone wires including all the required accessories like JBs, Coupling, External & Internal Bends, Elbows and end cap as per the detailed specification.(Refer Sec VI, Clause No.29).
25 X 12 mm size of PVC Mini trunking
Supply and open installation of following Sizes of MS boxes as per the detailed specification. (Refer Sec VI, Clause No.15.10).
150(W)X150(H)X80(D)mm, 1.6mm thick sheet MS Box.
Supply & installation (Embedment in concealed) of wall mountable powder coated MS telephone distribution boxes of different sizes with SS KRONE Base module, Cable entry, lock and key provision. (Ref. Sec V & Sec VI, Clause No.15.10).
300(W)X300(H)X120(D)mm MS Box. (for 50 pair)
Termination of the following sizes of PVC Sheathed, jelly filled, Flat/wire armoured PIJF UG Cable using Single Compression, Heavy Duty Gland connecting the cable to the equipment Telephone DBs etc. The rate shall include the cost of supply of Cable Gland. The Contractor shall arrange for drilling of holes wherever necessary for the completion of the work. (Refer Sec VI, Clause No.10.2).
Upto 20 Pair.
Supply and installation of Krone LSA PLUS disconnection Module and krone tool. (Ref Sec V).
Supply and installation of Krone LSA PLUS disconnection Modules 2/10 ADC LSA Plus (10 pair each)_Product part ID: 6089 2 011 – 02D at HASL building at IGCAR site as per the scope of work. (Ref Sec V).
Supply and installation of Krone insertion tool to terminate and cut wire on all disconnection modules. Product part no.6089 2 003-00.
Supply and installation of the following telephone accessories: (Ref Sec V).
Push button analog telephone instruments with line cord, spring cord and rosettee box.
CLIP telephone instruments with line cord spring cord and rosettee box.
Jumper wire (colour: Red/white & Blue/white) for telephone connection.
Bidder Name
SEKAR CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .