| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC 2ND ROSHAN TOWER S B SHOP BISTUPUR AREA EAST SINGHBHUM JHARKHAND | BISTUPUR | EAST SINGHBHUM | JHARKHAND | 831001 | ₹34.0 L Quoted ₹29.8 L | L1 | Accepted-AOC value within estimate |
| 2 | L2₹46.5 L+₹16.7 L (56.2%)Rejected-Finance DOOR NO 48 50 PRAKASAM STREET SKCL HARMONY SQUARE T NAGAR T NAGAR CHENNAI TAMIL NADU 600017 | CHENNAI | TAMIL NADU | 600017 | ₹46.5 L+₹16.7 L (56.2%) | L2 | Rejected-Finance PRICE HIGHER THAN DEPT ESTIMATE |
| 3 | Rejected-Technical MVI BLDG MILESTONE 87 SCHNEIDER ELECTRIC INFRASTRUCTURE LIMITED JAROD PO VADODOARA HALOL HIGHWAY VILLAGE KOTAMBI VADODARA | - | - | Rejected-Technical TECHNICAL BID NOT FOUND AND COMMERCIAL DEVIATION NOT ACCEPETED |
| Sl No | Description | Qty | Unit | SIEMENS LIMITED L1 | ABB INDIA LIMITED L2 |
|---|---|---|---|---|---|
| 1.00Supply of numerical relays. | |||||
| 1.01 | Supply of multiapplication based numerical relays with following features: Protection Parameters: •50/51 Overcurrent•50N/51N Earth Fault•49 Thermal Overload•48 Locked Rotor/Motor Start-up supervision•46 Negative Sequence•46PD,46M,49 F/T/C,49M,64R(High Impedance & Low Impedance),25,81U,81O,df/dt,32P/Q,32U,55U,55ITHD,60 P/N,59NU,37,50 L/R,79,95•Switch-on-to fault protection•27 Under Voltage•59 Over Voltage•66 Starts per hour•47 Phase Sequence / Voltage Unbalance•81U / 81O Under / Over Frequency•67 Directional Overcurrent•67N Directional Earth Fault•50BF Breaker Failure•74TC Trip Circuit Supervision•86 Master Trip/Lockout•94 Tripping Relay •46 Unbalance Current•60 VT Fuse Fail•Inrush Blocking•Harmonic Monitoring Metering Parameters
•Phase Current Ia, Ib, Ic •Neutral Current In • Voltage L-L / L-N •kW, kVA, kVAR • PF •Frequency •Energy kWh / kVARh
Event Recording
•Fault records •SOE logs • Disturbance recorder •Waveform capture
Communication
•IEC 61850 •Modbus RTU/TCP •DNP3 •Ethernet / RS485• One front RJ45 port, three rear RJ 45 port for IEC-61850 protocol,Draw out type with C.T shorting feature,Graphical LCD Display. DI/DO •16DI+10DO | 25 | EA | 72,479 ₹18,11,975 Lowest | 1,30,590.4 ₹32,64,760 |
| 2.00Installation,testing & commissioning of relays | |||||
| 2.01 | Retrofitting of relays in LV & HV switchboard
Scope of work:
• Removal of existing relay and associated wiring • Retrofitting, Testing & Commissioning of supplied relays.
• Supply of Single core wire for panel wiring if required, minor hardware such as screws, washers, lugs, ferules, adaptor plate,terminal blocks etc. • Panel cut-out modification if required & if necessary new panel door to be supplied.
• The relay setting will be done at our site as a part of commissioning.
• All the relays to be tested at factory automatic test bench before dispatch. However, we shall test the relays at site using three phase secondary Relay Testing Kit
(Omicron/ Equivalent) | 25 | EA | 28,420 ₹7,10,500 | 27,000 ₹6,75,000 Lowest |
| 3.00 | GST@18% | 1 | LOT | 4,54,045.5 ₹4,54,045.5 Lowest | 7,09,156 ₹7,09,156 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
21 May 2026, 3:00 pmClosed
ROHIT MUKHERJEE
IPPL HALDIA TERMINAL
Supply, retrofitting , testing of numerical relays for H.V, L.V switchboard
2026_IPPL_277069_1
IPPL/HAL/CAPITAL/LT-01/2026-27
Limited
Electrical Goods/Equipment
Fixed-rate
182 days
HALDIA
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹45,000
Yes
MS TEAM OR PHYSICALLY AT PLANT
27 Jun 2026
9 May 2026
22 May 2026
9 May 2026
21 May 2026
11 May 2026
14 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply of numerical relays. | |||||
| 1.01 | Supply of multiapplication based numerical relays with following features: Protection Parameters: •50/51 Overcurrent•50N/51N Earth Fault•49 Thermal Overload•48 Locked Rotor/Motor Start-up supervision•46 Negative Sequence•46PD,46M,49 F/T/C,49M,64R(High Impedance & Low Impedance),25,81U,81O,df/dt,32P/Q,32U,55U,55ITHD,60 P/N,59NU,37,50 L/R,79,95•Switch-on-to fault protection•27 Under Voltage•59 Over Voltage•66 Starts per hour•47 Phase Sequence / Voltage Unbalance•81U / 81O Under / Over Frequency•67 Directional Overcurrent•67N Directional Earth Fault•50BF Breaker Failure•74TC Trip Circuit Supervision•86 Master Trip/Lockout•94 Tripping Relay •46 Unbalance Current•60 VT Fuse Fail•Inrush Blocking•Harmonic Monitoring Metering Parameters
•Phase Current Ia, Ib, Ic •Neutral Current In • Voltage L-L / L-N •kW, kVA, kVAR • PF •Frequency •Energy kWh / kVARh
Event Recording
•Fault records •SOE logs • Disturbance recorder •Waveform capture
Communication
•IEC 61850 •Modbus RTU/TCP •DNP3 •Ethernet / RS485• One front RJ45 port, three rear RJ 45 port for IEC-61850 protocol,Draw out type with C.T shorting feature,Graphical LCD Display. DI/DO •16DI+10DO | - | EA | 100 | - |
| 2Installation,testing & commissioning of relays | |||||
| 2.01 | Retrofitting of relays in LV & HV switchboard
Scope of work:
• Removal of existing relay and associated wiring • Retrofitting, Testing & Commissioning of supplied relays.
• Supply of Single core wire for panel wiring if required, minor hardware such as screws, washers, lugs, ferules, adaptor plate,terminal blocks etc. • Panel cut-out modification if required & if necessary new panel door to be supplied.
• The relay setting will be done at our site as a part of commissioning.
• All the relays to be tested at factory automatic test bench before dispatch. However, we shall test the relays at site using three phase secondary Relay Testing Kit
(Omicron/ Equivalent) | - | EA | 100 | - |
| 3 | GST@18%(mailto:GST@18%25塹ᴻ䡿ⲯ嶂藄挧ꮥ) | - | LOT | 100 | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
TECHNICALBID.pdf
Tender Documents • 1.10 MB
BOQ_323594.xls
BOQ • 0.32 MB
DUEDATEEXTENSION.pdf
PDF • 0.17 MB
PREBIDQUERIES.pdf
PDF • 4.54 MB
CORRIGENDUM.pdf
PDF • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .