Tender Value
₹2.5 Cr
EMD Value
₹5.1 L
Closing Date
22 Sept 2020, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Upgrad of 24 nos of existing Hospitals for setting up of ICUs for treatment of patients of COVID 19 under Assam Critical Care Project 2020 at Dima Hasao (HVAC, Nurse Call System and Non-Medical Equipment MGPS, CSSD, Laundry, Incinerator, Curtain Trac
2020_PWBNH_18684_1
DIS-COV -19/19B (RT)
Open Tender
Civil Works - Building
Item Rate
120 days
Dima Hasao
Please refer Tender documents.
6 documents required · 6 mandatory
₹7,300
Assam State Road Board Maintenance (Road) Fund
₹5.1 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
18 Mar 2021
16 Sept 2020
22 Sept 2020
16 Sept 2020
22 Sept 2020
16 Sept 2020
18 Sept 2020
Amount
Supplying, instalation, testing and commissioning of Anti Microbial Coated construction, DIN VDE 0834 approved Hospital Communication System comprising of video streaming ready future oriented open technology plateform for all communication task and services like IP telephony,Smart card system,electro accoustic function and internet and internet services using its own Communication LAN and highest level of security against system failure, comprising of the following as required:- (Makes - Shrack / Rauland / Tunstall). VDE 0834 certified/ approved System Switch: S.I.T.C. of Main Controller system switch that forms a decentralised communications node for exchanging data between the connected system devices and the rest of the communications system, consisting of 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX), galvanically isolated conforming to EN 60950 and VDE 0834, 7 x RJ45 sockets, each for a 100Mb IP system port (IEEE802.3 100 BaseTX) for connecting all IP capable system modules, 1 x RJ45 socket, 100Mb IP Port (IEEE802.3 100BaseTX) for connecting communications, staff and ward terminals as well as control panel PCs or for redundant Connection, Control LEDs for indicating the current operating state, 2 x RJ45 sockets for connection of the external data bus, all IP system modules supplied with power using Power over LAN technology using its own communication LAN complete as required including event data base software to recall all calls generated by the patient and nursing staff with date and time.
Supplying, instalation, testing and commissioning of Anti Microbial Coated construction, DIN VDE 0834 approved Hospital Communication System comprising of video streaming ready future oriented open technology plateform for all communication task and services like IP telephony,Smart card system,electro accoustic function and internet and internet services using its own Communication LAN and highest level of security against system failure, comprising of the following as required:- (Makes - Shrack / Rauland / Tunstall). VDE 0834 certified/ approved Nurse Station Terminal:S.I.T.C. of Nurse Station Ward Terminal comprises of 5.6 “LC display for displaying all details, a smash proof glass panel (to protect the sensitive display from unnecessary contact during cleaning and other processes) , function keys for operating the system, Querying receiver for speaking discretely, Microphone and loudspeaker for hands-free speech (incl. volume control), automatic changeover between hands-free and discrete speaking , Electronic circuit board with controller and FlashProm, 100BaseTX interface to the system switch, 2.8m connection cable with an RJ45 connection plug, which is protected, from disconnection, for connecting to a connection module. The ward terminal shall display date and time, indication of all presence, all set reminedrs, indication of all calls in accordance with VDE0834. All call indications follow the priority and must display the exact location of the calls. The ward terminal shall be provided along with suitable connection module & back box. It should be supplied along with connection module & its back box for installation complete as required.
Supply, Installation, Testing & Commissioning of VDE 0834 certified/ approved Patient Handset Without Speech consisting of a plastic case in antimicrobial finish having Call button with nurse symbol with integrated finder and reassurance light on the top end of the unit, Membrane keypad in antimicrobial finish with integrated LEDS for operation, 1 call key, 2 lighting keys, 2.80 metre connection cable with auto-disconnecting RJ45 connector plug. It shall be supplied with cradel for holding patient terminals etc and as per tender technical specification.
Supply, Installation, Testing & Commissioning of VDE 0834 certified/ approved connection module for Patient Terminal. Connection module for patient handset shall consist of 1 x RJ45 socket marked in colour and with measures to ensure that the push button is correctly connected, including auto disconnect mechanism, 1 membrane keypad with 1 call button (red with nurse symbol) including a finder/reassurance light, 1 presence key/ cancel button (green) including a control LED etc and as per tender technical specification.
Supply, Installation, Testing & Commissioning of VDE 0834 certified/ approved Loop Powered Lamp Module. For optical indication of calls, presences and reminders in the relevant colours conforming to VDE0834 consisting of 5 light chambers with light reflectors for homogeneous illumination, 1 light chamber fitted with 3 ultra bright red LEDs, 1 light chamber fitted with 3 ultra bright white LEDs, 1 light chamber fitted with 3 ultra bright green LEDs, 1 light chamber fitted with 3 ultra bright blue LEDs, 1 light chamber fitted with 3 ultra bright Yellow LEDs, 2 RJ45 ports for loop connectivity etc and as per tender technical specification.
Variable Refrigerant Volume / Flow Air-conditioning System Supply, Instalaltion, testing and commissioning of Variable Refrigerant Flow /Volume (VRF/VRV) (with the latest technology/version) with All-Inverter driven Compressor, modular type airconditioning system with stepless modulation for both heating & cooling modes, complete with indoor and outdoor units, individual remote controller and centralized controller, interconnected refrigerant piping with insulation, Y joints, full charge of refrigerant gas including additional top up and oil, control cabling etc. as per detail given in specifications and having following items. The prices to be given in Indian rupees including all taxes and duties and delievered at site. Refrigerant to be used shall be - R 410 A only. It shall be complete as per specifications,with connectivity to automation for A/M status, RUN status & Remote start/stop command.(Bacnet/IP) with multi connection kits for each outdoor unit & First charge of refrigerant gas for the VRF/VRV Units & required MS frame work or required foundation & anti vibration pads for mounting the outdoor units. installation, testing & commissioning of air cooled VRV/VRF system shall include pipe pressure testing & flushing with nitrogen, charging of gas/oil etc. & will include all lifting/shifting etc. Air Cooled VRV / VRF Outdoor Unit Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at50°Cambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . Minimum. 22 H.P Cool / Heat Pump Unit
Expansion Kit, Communication PCB & Thermostat Supply, Installation, Testing & Commissioning of Electronic Type Expansion Kit, Communication PCB with Sensors, Corded Self Diagnostic Type Digital Thermostat, Controller, control box with internal wiring, AHU kit for each DX Type Units and other related accessories etc with connectivity to automation system for A/M status, RUN status & Remote start / stop command (Bacnet/IP). It should be complete as per manufacturing standards & as per directions of Engineer-in-charge. For 4000 CFM F/M AHU with 2 x 22.0 HP VRV ODU
Double Skin Floor Mounted VRV DX AHU 100% Fresh Air Supply, installation, testing and commissioning of factory fabricated Double Skin VRV DX Air-handling unit Floor mounted type fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with single / multiple AMCA certified backward curved plug fan with aerofoil design blades, VFD with built in harmonic filters, power control panel with necessary switchgears incoming & outgoing, blower suitable for static pressure as required (Fan Static given below is for guideline), and blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, 8 Row cooling coil made of Aluminium finned Copper tube with coil section, pre-filter section with non woven synthetic media MERV 8 filters in extruded aluminium frame, fine filter section with MERV 13 filters in extruded aluminium frame, Coilotron UV section only of 600 mm in length in floor mounted AHU, polished stainless steel drain pan made out of 22 G sheet duly insulated etc. without face and bypass dampers. The AHU panels shall be insulated with 48mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only. The complete AHU shall conform to specication & face velocity across cooling coil shall be limited to 152 MPM maxm. AHU DX coils shall be in tune with the requirement of VRV Outdoor Unit capacity and no divisions shall be made in cross sectional area of the coil. If multiple ins and outs of refrigerant pipe are required then coils shall be grouped into required rows keeping the cross sectional area of the coil constant. The capacity of Air-handlers shall be as follows: VRF/AHU/1 - 4,000 CFM Supply Air, 8 Row CC, 80 mm St. Pr., with other accessories as specified)
Double Skin Ceiling Mounted Exhaust Air Fan Section (MEU - Mechanical Exhaust Unit) Supply, installation, testing and commissioning of factory fabricated Double Skin Exhaust Air Fan Section ceiling mounted type fabricated out of extruded aluminium section with 0.8 mm pre-plasticized / pre-coated Galvanised steel sheet outside & 0.8 mm plain Galvanised steel sheet inside with forward curved blower, VFD with built in harmonic filters, power control panel with necessary switchgears incoming & outgoing, blower suitable for static pressure as required (Fan Static given below is for guideline), blower motor TEFC (IE3) type suitable for operation on 415 volts ± 10%, 50 Hz ± 5% AC supply, polished stainless steel drain pan made out of 22 G sheet duly insulated etc. without face and bypass dampers. The MEU panels shall be insulated with 23mm thick & 36 Kg/m³ density PU foam & shall have thermal break. The motor & blower assembly shall be mounted on Aluminium extruded section only. The capacity of MEU shall be as follows: MEU/1 - 5,500 CFM Supply Air, 40 mm St. Pr., with other accessories as specified)
AHU Mounted Coilotron UV System For Floor Mounted AHU Supply, installation, testing and commissioning of AHU mountable self contained and factory assembled Coilotron UV System with UL 1995 ABQK listed and UL 2043 certified, UV lamp life shall not be less than 11000 hours. Coilotron shall be installed in all floor mounted AHUs as specified herein. All the component / parts shall comply with the specification given in the tender. AHU supplier and coilotron supplier shall co-ordinate with each other regarding the fixing of the same in the AHU. For 2,000 to 8,000 CFM AHU
Refrigerant Piping for VRV / VRF System Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 15.86 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Refrigerant Piping for VRV / VRF System Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Condensate Drain Piping With Nitrile Rubber Insulation Supply, installation, testing and commissioning of condensate drain water piping of GI 'Medium' class complete with fittings like elbows, tees, reducers, bends, MS flanges, supports, welding, painting etc. as required conforming to tender specifications and of following sizes. Complete pipe shall be duly insulated with "O" class Closed Cell Elastomeric Nitrile Rubber of specified pipe section of specified thickness in the tender specification & suitable for indoor / outdoor application. Complete pipe insulation shall also have 200 g/m² factory laminated, treated woven Glass Cloth coating for mechanical and UV protection. 40 mm dia pipe , 19 mm Insulation
Rectangular GI Ducting (Factory Made - L Shape) Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 24 G (Up To 750 mm)
Rectangular GI Ducting (Factory Made - L Shape) Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. 22 G (751 to 1500 mm)
Site Fabricated GI Ducting Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required a) 24 G (Up To 750 mm)
Site Fabricated GI Ducting Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required b) 22 G (751 to 1500 mm)
Duct Accoustic Lining Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.
Duct Insulation Supplying and fixing of external thermal insulation on ducts with EPDM Rubber foam with completely closed cell structure as per specifications - Density 40-60 kg /cum , Class A as per ASTM E 84 , Class V-0 as per UL 94 and Mu value > 7000, tape & adhesive (pidilite SR -998) as required of following thickness. 13 mm
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Fresh / Exhaust air louvers with bird screen & damper
Volume control GI Dampers to be provided in supply & Exhaust air registers / terminals.
Isolator Switch With Metal Enclosure For 40 HP ODU (IP-65) 100A 4 pole RCBO for VRV Outdoor Units with sheet metal enclosure, rain protection etc. as required to suit the site condition.
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For Motor Up to 3.73 Kw 1 x 3C x 4 Sq. mm
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For Motor of 5.5 Kw 1 x 3C x 6 Sq. mm
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For VRV ODU Unit (From Panel to Isolators near ODU) 1 x 3C x 16 Sq. mm
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For VRV ODU Unit (From Panel to Isolators near ODU) 1 x 3C x 25 Sq. mm
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For VRV Outdoor (From Isolators to Unit) 1 x 3 C x 6.0 Sq. mm Copper Flexible Cable
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. For VRV Outdoor (From Isolators to Unit) 1 x 3 C x 10.0 Sq. mm Copper Flexible Cable
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. B) Control cabling (PVC insulated Copper conductor of 1.1 KV Grade armoured cable) 3C x 1.5 Sq. mm
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. Power cabling of XLPE insulated Aluminium conductor armoured cables of 1.1 KV Grade including cable end termination with brass compression glands & aluminium lugs etc as per specification. B) Control cabling (PVC insulated Copper conductor of 1.1 KV Grade armoured cable) 4C x 1.5 Sq. mm
C) Transmission & Control Wiring For VRV System Providing & fixing of control cum trans-mission wiring of copper between indoor and out door unit in 25 mm PVC Conduit. 3C / 2C x 1.5 Sq mm
Earthing Strip / Wires as per specs. Supply & laying of 8 SWG GI wire or in recess for loop earthing as required.
Supply & laying of 6 SWG GI wire or in recess for loop earthing as required.
Supply & laying of Rubber mat 1000 mm. Wide to withstand 1.1 KV dielectric strength as per latest IS 15652-2006.
Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 150 mm wide x 50 mm depth x 1.6 mm thickness.
Supplying and installing following size of perforated GI cable trays including bends. tee, reducers etc with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including bolts & nuts, suspenders etc as required. 300 mm wide x 50 mm depth x 1.6 mm thickness.
Supply, installation, testing & commissioning of Magnehelic Differential Pressure Gauge having measuring accuracy of 3%
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 100 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 150 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 200 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 250 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 300 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 350 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 400 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 450 CFM
5Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 00 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 600 CFM
Supply, installation, testing & commissioning of Constant Air Volume Boxes as per specification & capacity as given below:- 700 CFM
Industrial Drying Tumbler. Front Loading, Open Pocket, Steam Heated, 30 kg Capacity.
Flat Work Drying Ironer 1 roll, Heated Chest Type, Front Feed, Rear return, Steam Heated.
Washroom Trolley. S.S. 50kg capacity , Overall Size : 1000 x 600 x 780 ht.
Dry Linen Trolley. S.S. 50kg capacity , Overall Size : 1100 x 600 x 1500 ht.
Shelf Trolley. S.S. 100kg capacity , Overall Size : 1200 x 600 x 1700 ht.
Mobile Table. S.S. Top Size : 1150 x 750
Vacuum Finishing Table. 1200 x 750, Electric Steam Iron Teflon Shoe, aluminium armoured & spring loaded , Condensate Separator
Industrial Washer Extractor. 30 kg Capacity, High Spin, Suspended, Computer Controlled, Steam Heated.
Air Compressor 2 HP Single Stage with100 ltrs Tank
PRE ENGINEERED BUILDING SHED Wall (10’ht)- 50mm Aerocon/Vishakha Panel made of cement both sheet & portland cement inside; held on U Section or 8mm Cement board in boath side with thermocole insulation Roof- PPGI 0.45mm Colour Coated Sheet (Ultrashine/Essar/Asian) , Structure - (For Trush 2”x2”, Column 4”x2”, Purline 1.6” x 1.6”) False Ceiling – Gypsum/CFB Board 600x600 with T Grid Paint - (Asian Make) as per choice of Client, it will be range of Apex Rate Window - Aluminium Sliding Window 4’x3’ with Grill Door – Flush Door 7’x3’ Main Door – Aluminium Door half Glass/Half MDF Board Door 7’x4’’ Wiring - (Indomax/Anchor/I.S.I Mark) on Smart Modular switches fitting Toilets (EWC/WB (Cera/Parryware/I.S.I) and all fitting arrangement in PVC as per drawing, Urinal 02 Nos with fitting Bio Tank With Fitting Water Tank 1000 Ltr with Water Tower Foundation 0ne feet deep and one feet height Vetrified Floor Tiles of approved make all above complete as per approved design and as per direction of Engineer-in-charge.
Horizontal rectangular High Pressure High Vacuum Steam Sterilizer, Radial Hinged Double door, Inner chamber size: 450mm width x 450mm height x 1200mm length, 200-250 litres volume, fully automatic cycle operation with printer, electrical operated , as per technical specification
Washer disinfector with inbuilt drier,Double door, 250-275 litres capacity, as per technical specification
Ultrasonic V cleaner 30 litres capacity, as per technical specification
Strainless steel work table with double sink, as per technical specification
Spray Gunriser with eight attachments, as per technical specification
Stainless steel control and packing table with drawer, as per technical specification
Strainless steel work table with undershelf, as per technical specification
Table mounted heat sealing machine, as per technical specification
Stainless steel Table Mounted Gauze cutting machine, as per technical specification
Stainless steel Pass Box, Double door, size: 600mm x 600mm, as per technical specification
Stainless steel Storage Rack with 5 shelves, as per technical specification
Supplying installation testing commissioning of Bio-medical waste disposal system suitable for use in Covid ICU for disposal of all types of Hospital waste like PPE Kits, face mask, Gloves, etc. having capacity of 20Kg/hour strictly conforming to CPCB norms.
Providing, Fabricating and fixing of Hospital Cubicle Track System comprising of the following components and specifications: 1. CUBICLE TRACK Made of Metal Aluminum Alloy of Box size 1.7 x 20 x 25 mm with 50-60 microns thick powder coating in white color finish. Tracks are bendable to a radius of 300 mm at 90 degree to cover the whole bed. 2. CURTAIN Made of premium quality Stain Proof fabric with High quality Nylon Net of 18” and 24” on top. 3. SUPPORTING SYSTEM OF CONSISTS OF THE FOLLOWING MATERIAL: Wall Bracket- Made of CRC steel with white powder coating finish. I. Bride Clamp- Made of CRC steel with white powder coating finish. II. Roof Suspension- Made of aluminum pipe of 12.5 mm & 19.5 mm diameter. The Upper Circular Plate made of aluminum with 50.4mm diameter thickness. These are with white powder Coating (outer surface) finish & are of variable height fixed with the ceiling with anchors, bolts, screws etc. 4. CURTAIN REMOVABLE POINT- Made of SS for simple loading & unloading of curtains. (Also serves as an end hook retainer). 5. Runner- Comprises of wheel type runners made of Teflon for easy and smooth sliding of the curtain. all complete as per Direction of Engineer-in-charge.
MEDICAL OXYGEN SYSTEM Supply, installation, testing & commissioning of Oxygen Manifold with 8 Nos. pigtailpipes for 2+2 cylinders and Non-returnvalves, as per enclosed technical specifications and approved make (without cylinders)
Supply, installation, testing & commissioning of Fully Automatic Oxygen Contr0l Panel, as per HTM-2022/02-01ofUK/NFPA99C of USA as per enclosed technical specifications and approved make
Supply, installation, testing & commissioning of Oxygen Manifold Emergency for 2 Cylinders, as per enclosed technical specifications and approved make- (without cylinder)
Supply, installation, testing & commissioning of Oxygen Outlets with matching probes, CE certified with four digit notafied number as per enclosed technical specifications and approved make- (Imported)
Supply, installation, testing & commissioning of Oxygen Flowmeter with Humidfier Bottle CE Certified with four digit notafied number /UL Listed,as per enclosed technical specifications and approved make - (Imported) for critical area
VACCUM SYSTEM Supply, installation, testing & commissioning of Duplex Vacuum central system with Duplex pump only complete with electrical control panel as per enclosed tender specification and approved make sufficient for 11 bed
Supply, installation, testing & commissioning of Vacuum Outlets with matching probes, CE certified with four digit notafied number as per enclosed technical specifications and approved make- (Imported)
Supply, installation, testing & commissioning of Ward Vacuum unit CE Certified as per enclosed tender specification and approved make
MEDICAL COMPRESSED AIR SYSTEM Supply, installation, testing & commissioning of Duplex Air Compressor complete with Compressed air plant complete as per enclosed technical specification and approved make sufficient for 11 bed
Supply, installation, testing & commissioning of Air-4Bar Outlets with matching probes, CE with four digit notified number as per enclosed technical specifications and approved make-(Imported)
Supply, installation, testing & commissioning of MEDICAL Grade BS EN: 13348 Kite Marked COPPER PIPE 12mm
Supply, installation, testing & commissioning of MEDICAL Grade BS EN: 13348 Kite Marked COPPER PIPE 15mm
Supply, installation, testing & commissioning of MEDICAL Grade BS EN: 13348 Kite Marked COPPER PIPE 22mm
Supply, installation, testing & commissioning of MEDICAL Grade BS EN: 13348 Kite Marked COPPER PIPE 28mm
Supply, installation, testing & commissioning of Medical Area Line Pressure Alarm -as per HTM 2022/02-01/ NFPA99C as per enclosed technical specifications and approved make Area Line pressure Alarm-3 gases
Supply, installation, testing & commissioning of Medical Area Valve Service Unit ( Valve Box with isolation valve) as per CE certified/UL listed as per enclosed technical specifications and approved make 3 Gases
Supply, installation, testing & commissioning of Aluminum extruded Bedhead Panel long four feet with electrical & provision of gas outlet as per enclosed technical specifications and approved make
Supply, installation, testing & commissioning of Electrical Panel for Air compressor &Vaccum Pump as per enclosed technical specifications and approved make
Supply, installation, testing & commissioning of High Pressure hose as per enclosed technical specifications and approved make
Any other unforeseen item of work which are not covered in the above items of this BOQ that may be required at site during execution having an estimated provision of Rs.7,73,716.00 (Including GST). The rates for such individual additional items of work shall be in percentage Above/At Par /Below the corresponding APWD SOR/ Market Rate Analysis in proportion between the quoted lump sum rate of the bidder and the estimated provision. Note:- The amount against this item has been kept as a provision for any unforseen additional items of works which may be needed during the execution of the work, and is considered as one single job. A Lump sum rate is to be quoted against the job constituting the unforeseen additional items of works, and shall not be less than 10% below. Bids not complying to this shall summarily be rejected.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .