| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC N 77 A PAHARPUR ROAD CALCUTTA 24 700024 | KOLKATA | KOLKATA | WEST BENGAL | 700024 | ₹4.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹4.9 LRejected-AOC | ₹4.9 L | L2 | Rejected-AOC L2 |
| 3 | L3₹5.0 LRejected-AOC 14 9 CHOWBHAGA ROAD CALCUTTA 39 700039 | KOLKATA | WEST BENGAL | 700039 | ₹5.0 L | L3 | Rejected-AOC L3 |
Tender Value
₹4.8 L
EMD Value
₹10,000
Closing Date
21 Jan 2026, 11:00 amClosed
E.E.(E)/Z-V/GRU
LIGHTING department THE Kolkata Municipal Corporation E/3, Circular Garden Reach Road, Kolkata-700 024 West Bengal
RENOVATION OF PARK LIGHTING SYSTEM AT NONA PUKUR, BORO PUKUR AND OTHER SURROUNDING AREAS IN WARD NO. 136, BR-XV.
2026_KMC_986018_1
KMC/LTG/RS/72/25-26/182
Open Tender
Electrical Work/ Equipment
10 days
WARD 136
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
8 Mar 2026
10 Jan 2026
21 Jan 2026
10 Jan 2026
21 Jan 2026
10 Jan 2026
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
Hoisting fixing and commissioning of luminaries including making necessary connection and earthing attachment: HPMV/HPSV luminaries/LED fittings of any wattage.
Removing of luminaries with lamp from the pole/column and keeping them ready for dispatch as per direction of EIC: HPMV/HPSV luminaries/MH/LED street light fittings.
TRIDENT LIGHT FITTING (POST TOP LANTERN) COMPLETE WITHOUT LAMP, SUITABLE FOR S/C CAP LAMP E27 AS PER SAMPLE_AS PER LAST PURCHASE RATE OF KMC CENTRAL STORE
SUPPLY OF 12 WATT LED LAMP ES CAP_AS PER LAST PURCHASE RATE OFKMC CENTRAL STORE
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 11. Providing CC (6:3:1) muffing 0.3 mtr dia upto the height of 0.3 mtr. above the ground level around the pole base complete with 3 mm thick neatly finished cement plaster all-round after dismantling the unserviceable muffing if necessary
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.(i)1st coat of aluminium paint over 1 coat of RO priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.ii2nd coat of aluminium paint over 1st coat
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core
Laying on Wall / surface with Saddles / clamps.(a)Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (HOT Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core
Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core
Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/):Size in Sq. mm, No & dia. of wire in mm , No of Core - 10 1/3.55 2
Laying through Underground Trech.(a)Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. B. REPAIRING 2. Welding in M.S. structural work with gas or electric: (b) Continuous weld.
CHAPTER - VIII SUPPLYING OF MATERIALS E. E. R. W. MS BLACK PIPE 8.15 Sypply of E.R.W.M.S. (Electrical Resistant Welded M.S.) black pipe of ISI Mark as per relevent IS Specification ( heavy quality ) having wall thickness not less than 5 mm. [N.B.: The rates for supply of TATA Make pipe will be arrived at by adding 20% of the corresponding rates ] Diameter in mm (Internal)150
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.3 M.S. Pipes 2.3.1 Gas cutting of M.S. pipes and/or M.S. plates of different thickness all complete as per specification and direction of the Engineer-in- Charge. Thikness in mm 5mm to 8mm thick plate
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 138. GI reducer (heavy) 80/65 mm x 20 mm
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision FOR housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision FOR earthing attachment Standard (SKB8)
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.36 MB
FORM.pdf
Tender Documents • 0.64 MB
BOQ_2406888.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid