Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹28.4 L+₹5.4 L (23.5%)Rejected-Finance SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE(AF) NAL
GE (AF) Nal, AF Stn Nal Bikaner (Raj)-334001
As described in Bill of quantities
2021_MES_462653_1
GE (AF) NAL/T-15/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE(AF) NAL BIKANER
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) NAL
₹46,000
GE(AF) NAL BIKANER
27 Oct 2021
26 Jul 2021
7 Sept 2021
26 Jul 2021
30 Aug 2021
9 Aug 2021
29 Jul 2021 - 6 Aug 2021
7 Aug 2021
Amount
M&L taking out burnt transformer of voltage stabilizer 5 KVA and rewinding with super enamelled copper winding wire including varnishing with super quality varnish, suitable size of thimble, mica paper and testing after rewinding complete all as specified and directed. Note: Transportation of transformenr to factory / workshop and back to site shall be deemed included in the unit quoted rate.
S&F in replacement of circuit plate of existing make and model suitable for 5 KVA voltage stabiliser complete all as specified and directed.
S&F in replacement the following items with existing make and model and provided with new and suitable for 5 KVA voltage stabiliser complete all as specified and directed :-
Time delay relay
Toggle switch
Auxiliary transformer 24 Volt
Step up relay
PVC connector base plate.
S&F in replacement of unserviceable MS Sheet body of 16 SWG suitable for 5 KVA voltage stabilizer including painted with 2 coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs PVC insulated and sheathed copper conductor cable of size 40/0.0076mm, 3 core complete all as specified and directed.
M&L shifting of split AC 1.5/ 2.0 TR with indoor unit, outdoor unit and copper tubes to a new position, re-fixing the same in new position and testing up to the satisfaction of Engr in charge complete all as specified. Note:- Unit rate of this item included the cost of making necesaary holes, drilling etc and all electric and gas tube connection.
Disconnection and taking out, reinstallation and connection of spilt AC of any capacity after carry out the following maintenance/servicing task :- (a) Cleaning of Air filter with vacuum cleaner (Pressurized air) & washing of the fins using pressurized water by using portable pump for AC servicing. (b) Cleaning of complete AC unit by hand blower removing dust complete (For split AC indoor out door unit) (c) Servicing blower motor complete. (d) Complete job for a particular AC shall be carried out on prompt basis and no part work shall be left for next day. (e) The split AC before servicing shall be covered with 'closed type horizontal air conditioner wash bags' for insite servicing at critical locations.
S&F as in repairs condenser unit suitable for 2/1.5 Ton capacity split AC of existing make and model complete all as specified and directed. Note:- Contractor is adviced to verify the make and model before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
S&F as in repairs hermetically sealed unit compressor suitable for split/window type AC 1.5 Ton capacity of existing make and model complete all as specified and directed.
All as per Srl item No 9.00 here-in-before but for split/window type AC 2 Ton capacity.
Supply and charging only refrigerant gas R - 22 Note : Cylinder for refrigerant gas shall be arranged by the contractor at his own cost.
Supply and charging only refrigerant gas R - 134 Note : Cylinder for refrigerant gas shall be arranged by the contractor at his own cost.
S&F as in repairs copper tube ½ inch bore incl insulation of AC pipe with insulation complete all as specified and directed.
S&F as in repairs copper tube 3/8 inch bore incl insulation of AC pipe complete all as specified and directed.
Disconnection, taking out and reinstallation of window AC of any capacity after carried out the following maintenance/servicing task including connection :- (a) Cleaning of Air filter with vacuum cleaner (Pressurized air) & washing of the fins using pressurized water by using portable pump for AC servicing. (b) Cleaning of complete AC unit by hand blower removing dust complete (c) Servicing blower motor complete.
S&F as in repairs condenser unit suitable for 2/1.5 Ton capacity window type AC of existing make and model complete all as specified and directed. Note : Labour for taking down and fixing shall be deemed included in the unit quoted rate.
S&F as in repairs to the following items with new of existing make and model suitable for Split/Window type AC 1.5/2 Ton capacity complete all as specified and directed :- Note:- Contractor is hereby advised to get familiar with the amake and model of AC before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
Blower Motor
Remote control
Blade for blower motor
Starting relay
Over load relay
Thermo state switch
Starting Capacitor any capacity
Running Capacitor any capacity
Insulation for copper tube of split AC of capacity 1.5/2 ton with foam mat complete all as specified.
Supply and fixing as in repair PCB board for Window/ Split AC upto 2 Ton of existing make and model complete all as specified and directed.
Supply and fixing as in repair window AC grill for Window AC upto 2 Ton of existing make and model complete all as specified and directed.
S&F as in repairs hermetically sealed unit compressor suitable for refrigerator of 165 litre capacity of existing make and model complete all as specified and directed. Note:- Contractor is hereby advised to get familiar with the make and model of refrigerator before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
All as per Srl item No 20.00 here-in-before but for Refrigerator of 300 to 320 litre capacity.
All as per Srl item No 20.00 here-in-before but for Deep freezer of 300 to 320 litre capacity.
S&F as in repairs following items with new of existing make and model suitable for refrigerator 165 to 320 capacity complete all as specified and directed :- Note:- Contractor is hereby advised to get familiar with the make and model of refrigerator before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
Blower Motor
Starting relay
Over load relay
Thermo state switch
Starting Capacitor suitable capacity
Running Capacitor suitable capacity
Vegetable Tray with glass cover.
Ice tray aluminium
Rubber door gasket magnetic type
Shelf mesh type PVC coated suitable size
S&F as in repairs hermetical sealed unit compressor suitable for water cooler of 40/80 litre capacity of existing make and model complete all as specified and as directed. make : LG / Voltas / Blue Star Note:- Contractor is hereby advised to get familiar with the amake and model of water cooler before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
All as per Srl item No 24.00 here-in-before but for 60/120 litre capacity
S&F in replacement to the following items with new of existing make and model suitable for water cooler 40/60/80/120 ltrs capacity complete all as specified & directed . Note:- Contractor is hereby advised to get familiar with the amake and model of water cooler before quoting the rate. Nothing extra shall be admissible on account of any misunderstanding.
Starting relay
Over load relay
Thermo stat switch
Starting Capacitor suitable capacity
Running Capacitor suitable capacity
Taking down carefully the following accessories/parts from existing desert cooler and providing new accessories/parts in desert cooler details as given in below
Fan motor Single phase AC Electric Motor 230V, 50 Hz incl 230V, 50 Hz, cap 4 mfd speed 1275RPM output 105W.
Submersible water pump of PVC body Single phase 230V suitable for 1.00 metre head.
Submersible water pump of PVC body Single phase 230V suitable for 2.5 metre head.
Plastic water distribution socket
PVC pipe 15 mm bore
PVC elbow 15mm bore
Capacitor 4/6 mfd
Fan blade set
Regulator switch 3 speed.
Switch piano type 5 Amp , single pole.
Front grill of PVC
Wood wool pad set of three of best quality as per existing in size
Wood wool pad set best quality for centralised cooler of size as per existing
Side panel made of 22 gauge MS Sheet galvanized of required size for desert cooler
Side panel of size 1.50m X 0.77m for centralised cooler made of 22 gauge MS galvanized Sheet
Side panel of size 1.25m X 1.50m for centralised cooler made of 22 gauge MS galvanized Sheet
Bottom tank of size 1.80m X1.53mX0.30m for centralised cooler made of 22 gauge MS galvanized Sheet
M&L rewinding of 3 Phase fan motor of 1.5 HP capacity suitable for 900mm sweep with suitable size of super enamelled copper wire incl taking down and refixing after rewinding the same in the existing loacation complete all as specified and directed.
M&L as in repair for factory fabricated duct made out of 18 guage GI sheet complete with nut bolts and other accessories complete all as specified and directed.
Removing old worn out / rusted MS Sheet base and sides of Desert cooler of any capacity and providing new MS Sheet base of 20 SWG including fixing in position complete all as specified and as directed. Note: – The cost of welding / riveting, finishing shall also be deemed to include under the unit rate of item.
Taking down desert cooler of any make / capacity carefully without damaging, scraping old paint, completely and painted with 2 coat of synthetic enamel paint over a coat of red oxide primer after filling the cavities of MS Sheet with filler and inner surface of bottom & sides painted with two coat of black Japan paint completed all as specified . Note : Taking down and re-fixing in the same position after painting work shall be deemed to include in the unit rate of this item.
Taking down carefully ceiling fans of 1200 mm sweep of any make from existing fan hook and refixing in same position after necessary repairs incl connecting up with flexible twin core cable 23/.0076 from ceiling rose or connector to fan complete all as specified and directed. Note :- Spares / parts to be replaced and rewinding shall be measured and paid for separately against respective item of this schedule.
Taking down carefully ceiling fans of 1400 mm sweep of any make from fan hook and refixing in same position after necessary repairs etc incl connecting up with flexible twin core cable 23/.0076 from ceiling rose or connector to fan complete all as specified and directed. Note :- Spares / parts to be replaced and rewinding shall be measured and paid for separately against respective item of this Schedule.
All as per Srl item No 33.00 here-in-before but exhaust fan of any sweep and make.
M&L as in repair rewinding of ceiling fan of sweep 1200mm, of any make & model, with supper enameled copper winding wire of same size as per old winding wire and confirming to relevant IS including replacement of insulation materials, varnishing, greasing & lubricating to ball bearings, GM bushes and testing etc complete all as specified and directed.
M&L as in repair rewinding of ceiling fan of sweep 1400mm, of any make & model, with supper enameled copper winding wire of same size as per old winding wire and confirming to relevant IS including replacement of insulation materials, varnishing, greasing & lubricating to ball bearings, GM bushes and testing etc complete all as specified and directed.
All as per Srl item No 36.00 here-in-before but exhaust fan of 300mm sweep.
All as per Srl item No 36.00 here-in-before but exhaust fan of 450mm sweep.
All as per Srl item No 36.00 here-in-before but exhaust fan of 600mm sweep.
All as per Srl item No 36.00 here-in-before but pedestal / air-circulator fan of any size make and model.
Supply only ball bearing of size 6201 to 6204 for ceiling/exhaust / Pedestal / Table / Cabin Fan of any make and sweep, complete all as specified and directed.
Supply only GM bush for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed
Supply only Stainless steel shaft for ceiling/exhaust /Pedestal /Table/Cabin Fan of any make and sweep complete all as specified and directed.
Supply only capacitor 2.5/3.15 mfd for ceiling /cabin fan/ table fan of any sweep and complete all as specified.
Supply only capacitor 4 mfd for Exhaust fan of any sweep and complete all as specified and directed.
Supply only rubber seal for ceiling fan complete all as specified and directed.
Supply only mild steel U-clamp including 10mm dia bolt, nut, washer and split pin for ceiling fan completed all as specified and directed.
M&L dismantling of unserviceable monoblock pumpset with motor 3 phase 415 volts 11KW/15 HP at 2880 RPM suitable for monoblock pump Model KDS - 1537+ Make : Kirloskar, strip opening and taking out rotor carefully, cleaning of rotor and stator, Checking the rotor bearings, pump bearings,gaskets, impeller keys, terminal plate, Gun Metal Bushs, Cooling fan blades, winding etc complete and re-assembling the motor including replacement of studs with nuts, retesting of motor for full RPM and full discharge water after coupling with pump set complete all as specified and directed. Note - (i). The unit rate quoted above shall be deemed to include only for removing the motor and pumpset to perform the above mentioned works. (ii). Any parts / spares required to make it fully functional shall be measured and paid for separately under relevant item as supply only.
M&L taking out burnt stator winding with out damage to stator body of 11KW/15 HP at 2880 RPM suitable for monoblock pump Model KDS - 1537+ Make : Kirloskar, rewinding the electric motor by super enameled copper conductor (Wire) including providing insulating Mika paper in stator slots, PVC sleeves, varnish the winding complete. all as specified and directed. NOTE:- Contractor shall submit the guarrantee for two year of rewinding of motor from the date of completion of work.
All as per item No 49.00 here-in-before but for 7.5 HP at 700 RPM electric motor suitable for FRP cooling tower of make Mihir Engineers Ltd model FM9
All as per item No 49.00 here-in-before but for Eletric Motor 11 KW /15 HP, 1455 RPM 3 phase 415 Volts, IP 55, Type HX160MLD4 complete all as specified & directed.
All as per item No 49.00 here - in - before but for Eletric Motor 3.75 KW /5 HP, 1430 RPM 3 phase 415 Volts, IP 55, Type HX112 HMN4 complete all as specified & directed.
Supply only following spares for fixing into monoblock / Centifugal pump set, 1400 LPM at 51 Mtr Head directed coupled with 3 phase 5/7.5/15 HP 415 volts electric motor of any Make/Type
Terminal plate (for motor)
Ball bearing 6307
Gun metal bush
Neck ring for impeller
Plastic cooling fan
Gun metal impeller with Key
Rubber Seal
Supply & fixing as in repairs MCCB 3 pole 400 Amps with breaking capacity 36KA DH 400 complete all as specified & directed.
Supply & fixing as in repairs MCCB 3 pole 200 Amps with breaking capacity 36 KA DH200 completet all as specified & directed.
Supply & fixing as in repairs MCCB 3 pole 125 Amps with breaking capacity 25 KA DH125 complete all as specified & directed.
Supply & fixing as in repairs MCCB 3 pole 100 Amps with breaking capacity 25 KA DU100 complete all as specified & directed.
Supply & fixing as in repairs MCCB 3 pole 63 Amps with breaking capacity 25 KA complete all as specified & directed.
Supply & fixing as in repairs MCCB 3 pole 32 Amps with breaking capacity 25 KA complete all as specified & directed.
Supply & fixing as in repairs Power Contactor 3 pole 415 Volts MNX-A1 of range 40A complete all as specified & directed.
Supply & fixing as in repairs Power Contactor 3 pole 415 Volts of range 30A complete all as specified & directed. Type MNX 18
Supply & fixing as in repairs Power Contactor 3 phase 65 A, 415 V, 50 Hz complete all as specified and directed.
Supply & fixing of Bimetal Overload Relay suitable for Power Contactor MNX - A1, 3 pole 415 Volts complete all as specified & directed.
Supply & fixing of Bimetal Overload Relay suitable for Power Contactor MNX 18, 3 pole 415 Volts complete all as specified & directed.
Supply & fixing of Electronic Timers ST 100 suitable for Power Contactor MNX A-1, 3 pole 415 Volts all as specified & directed.
Supply & fixing of Electronic Timers ST 100 suitable for Power Contactor MNX 18, 3 pole 415 Volts all as specified & directed.
Supply & fixing of Motor Protection Circuit Breaker type MNX - G0 suitable for Power Contactor MNX A-1, 3 pole 415 Volts all as specified & directed.
Supply & fixing as in repairs Motor Protection Circuit Breaker type MNX - G0 suitable for Power Contactor MNX 18, 3 pole 415 Volts all as specified & directed.
S & F in repair round type water pressure gauge with adopter graduated both in kg/cm sq and LBS complete all as specified and as directed
Opening of Water Cooled Chiller - Scroll unit 85 TR Capacity comprising of 04 Nos of Condensor model YCD -21 make Blue star suitable for AC Plant, from both ends, cleaning, removal of deposited scales into the tube by means of using chemicals and suitable descaling pump without damaging the copper tubes, reconnecting with the system and testing to its full load capacity complete all as specified and as directed.
S&F as in repairs Solenoide Valve suitable for Compressor 21.5 TR Capacity of model SY 300 A4MBB make Blue star for AC Plant, reconnecting with the system and testing to its full load capacity complete all as specified and as directed.
Supply & Fixing as in repairs Refrigerant drier filter complete all as specified and directed.
Supply & Fixing as in repair Air filter for 27000 CFM AHU unit for type Air conditioning plant micron type complete all as specified and directed.
Supply & Fixing as in repair Air filter for 19000 CFM AHU unit for type Air conditioning plant micron type complete all as specified and directed.
Supply & Fixing as in repair Air filter for 8000 CFM AHU unit for type Air conditioning plant micron type complete all as specified and directed.
Supply & Fixing as in repair Air filter for 4000 CFM AHU unit for type Air conditioning plant micron type complete all as specified and directed.
Supply & Fixing as in repair water control Valve 100mm bore half turn butterfly type made out of brass complete all as specified and directed.
Supply & Fixing as in repair water pressure gauge as per existing pressure and size half turn type complete all as specified and directed.
Supply and fixing as in repairs compressor MP-SCROLL-SY 300 of capacity 21.5 TR including lifting, fitting, leak testing, vaccumising, gas charging and commissioning as per existing in site with complete accessories complete all as specified and as directed. Note :- Gas to be charged shall be measuared and paid for separetely under relevant item of schedule
S & F in repairs Mild steel work in framed work such as grills, Gates, Framed guard bars, gratings, ladders, Cable trays, Fencing and base channels etc., with ends of bars soldered/welded and/ or riveted, or forged into spikes, and similar work confirming to Fe 290 E-165 incl two coats of mettallic paint over a coat of metalic primer complete all as specified and directed.
M&L Painting of AC plant including condenser / chilled water pump motor set, cooling tower, pipe lines, foundation chanels of motors, supporting chanels etc complete with one coat of anti-corrosion epoxy paint of approved colour including preparation of surfaces by cleaning, rubbing complete all as directed.
Supply and fixing as in repairs filter drier - UDK 417 S as per existing in site with complete accessories complete all as specified and as directed. Note : cost of welding and brazing of the connections also included in the unit quoted rate.
Supply and fixing as in repairs brass safety valve of existing make and model on site with complete accessories complete all as specified and as directed.
Supply and fixing as in repairs expansion brass valve - HFES15 as per existing suitable for 21 T.5 TR capacity compressor in site with complete accessories complete all as specified and as directed.
Supply and fixing as in repairs LP switch - auto reset - 35 PSI as per existing in site with complete accessories complete all as specified and directed.
Supply and fixing as in repairs Pre relief valve in R22- NPT-300 PSIG of size 3/8" x 3/8" and pressure 350 PSI suitable for 21.5 TR capacity compressor in site with complete accessories complete all as specified and directed.
Supply and fixing as in repairs thermister probe alongwith 3 mtr wire as per existing in site with complete accessories complete all as specified and directed.
Supply and fixing as in repairs crankcase heater - 130W-SY-300 as per existing in site with complete accessories complete all as specified and directed.
Supply and fixing as in repairs Flow Switch - WT Rapid 1INConn RC62 as per existing in site with complete accessories complete all as specified and directed.
Material and Labour for Leak testing of chillers and rectification of existing chiller system complete all as specified and directed.
Supply and fixing as in repair current transformer CT100-SCROLL as per existing in site with complete accessories complete all as specified and directed. Note : The repair to AC Plant shall be carried out by the authorised dealer of AC plant.
Supply & Fixing in repairs fin for FRP cooling tower size as per existing sample including cleaning of cooling tower complete all as specified and directed
Supply, fixing, installing and testing in repair hermetically sealed unit compressor of capacity 3.75 TR suitable for package type AC plant complete all as specified and directed
Comprehensive maintenance of AC plant (Centralised/ Package type) in Summer as per daily check and cleaning, monthly, quarterly, half yearly maintenance including first hand repairs, AC plant comprising of compressor, motors, condenser, AHU, refrigerant piping, electrical SF/FS panel, instruments starters, strip heaters and provision of control cabling/wiring complete all as specified and directed by Engineer-in-Charge for smooth and efficient performance of AC plant to achieve desired in side conditions through out the period for the following plants :- (i) 2 x 85 = 170 TR capacity centralised AC (in operation ) Make : Blue Star (ii) 1 x 85 =85 TR TR capacity centralised AC (as standby ) Make : Blue Star (iii) 3 x 7.5 TR Capacity Package type AC (in Operation) Make:Feeders Lloyd (iv) 1 x 7.5 TR Capacity Package type AC (as standby) Make : Feeders Lloyd Note : (a) The cost of all the parts except major parts of AC Plant required for replacement are deemed to be included in the quoted rate. (b) Plant shall be run round the clock, therefore contractor 's manpower shall attend the plant on daily basis including Sunday and holiday. (c) All the T&P required for comprehensive maintenance shall be arranged by the contractor at his own end. (d) Company's Engineer / mechanic shall visit the plant on every alternative month to ensure perfect running of plant. (e) In case of emergency during odd hours, contractoralongwith mechanic / manpower shall report the site. The plant shall be made in functioning condition within reasonable time. However, on request, company's Engineer / mechanic shall also be called for to attend the defect and nothing extra shall be admissible on this account.
Comprehensive maintenance of AC plant (Centralised/ Package type) in Winter as per daily check and cleanaing, monthly, quarterly, half yearly maintenance including first hand repairs, AC plant comprising of compressor, motors, condenser, AHU, refrigerant piping, electrical SF/FS panel, instruments starters, strip heaters and provision of control cabling/wiring complete all as specified and directed by Engineer-in-Charge for smooth and efficient performance of AC plant to achieve desired in side conditions through out the period for the following plants :- (i) 2 x 85 = 170 TR capacity centralised AC (in operation ) (ii) 1 x 85 =85 TR TR capacity centralised AC (as standby ) (iii) 3 x 7.5 TR Capacity Package type AC (in Operation) (iv) 1 x 7.5 TR Capacity Package type AC (as standby) Note : (a) The cost of all the parts except major parts of AC Plant required for replacement are deemed to be included in the quoted rate. (b) Plant shall be run round the clock, therefore contractor 's manpower shall attend the plant on daily basis including Sunday and holiday. (c) All the T&P required for comprehensive maintenance shall be arranged by the contractor at his own end. (d) Company's Engineer / mechanic shall visit the plant on every alternative month to ensure perfect running of plant. (e) In case of emergency during odd hours, contractor alongwith mechanic / manpower shall report the site. The plant shall be made in functioning condition within reasonable time. However, on request, company's Engineer / mechanic shall also be called for to attend the defect and nothing extra shall be admissible on this account.
S&F as in repair discharge compressor copper valve for package type AC plant of capacity 3.75 ton suitable for replacement of existing make at site complete all as specified and directed.
S&F as in repair suction compressor copper valve for package type AC plant of capacity 3.75 ton suitable for replacement of existing make at site complete all as specified and directed.
S&F as in repairs suction strainer of existing part Make ACCLE complete all as specified and directed.
S&F as in repairs Pilot solonide valve 3 way 6 mm dia made of brass complete all as specified and directed.
M&L as in repairs insulation to 150mm bore MS pipe by 13mm thick closed cell chemically cross linked fire retardant polyethelyene foam insulation of density 30 Kg/cum.The thermal condctivity of the materials should not exceed 0.035W/Mk at an average temp 40 ºC, covered with aluminium faced foil complete with application with rubber based adhesive pidilite SR 998 and 50mmx3mm thick self adhesive tape on both longitudinal & transverse joints simulteneously complete all as specified and directed. Note :- Quantity shall be measured according to length of MS pipe.
All as per description of serial item No. 100.00 here in before but to 80mm bore pipe
All as per description of serial item No. 100.00 here in before but to 50mm bore pipe
Servicing and cleaning of double skin AHUs comprising of cooling coil and pan, Washing filter with the help of pressure jet and cleaning with de scaling chemicals (ISI marked) and outside by vacuum cleaner, cleaning PAN humidifier and dehumidifier, oiling/greasing of moving parts, cleaning Hot water generator and brazing, if required. incl testing complete all as specified and directed for the suitable capacity of following AC Plants.
4000 CFM capacity
8000 CFM capacity
19000 CFM capacity
27000 CFM capacity
S&F as in repair Fan Belt for AHU induction motor suitable for 3/5 HP motor as per make and model existing at site complete all as specified and directed.
S&F as in repair Fan Belt for AHU induction motor suitable for 15 HP motor as per make and model existing at site complete all as specified and directed.
S&F as in repair Fan Belt for AHU induction motor suitable for 20 HP motor as per make and model existing at site complete all as specified and directed.
Taking down defective micro processor controller, phase controller and connecting items from panel board of Water cooled chiller unit of capacity 4X21.5 TR, make Bluestar, Model as per existing at site, refixing the same after necessary repair/ replacement of parts defective PCB, relays, micro processer based controller as required including testing and commissioning of chiller unit of the satisfication of Engr-in-Charge. Note : Contractor also submitt the test sheet of relay functioning of chiller unit after completion of job.
Supply & fixing as in repair rotating sprinkler for cooling tower model Delta suitable for capacity 3 X 85 TR AC Plant complete all as specified and directed.
Maintanence, cleaning and servicing of RO plant for 11 months having capacity 1000 ltrs/hr by checking of electric wiring, changing of PVC pipes of any sizes, changing of filters etc incl complete servicing of membrane (three times) front and reverse feeding with the help of salt, chemical and servicing of carbon filter and paper filters complete all accessories upto satisfication of Engr-in-Charge Note : (i) Parts / PVC pipes shall be measured and paid for separately as 'Supply only'. However, the labour element is included in unit rate of this item. (ii) Each Paper filter and Woollen Filter shall be changed once in every month upto 11 months (iii) The unit quoted rate shall include the cost of anti-scaling chemical, Sodium Hydroxide (iv) In case, the contractor desire part payment, the same shall be calculated on the proportional basis for the actual work done.
Supply only following spares for providing in RO plant :-
Paper filter and woolen filter (Paper filter for filterimg out 5 micron particles and woolen filter for filtering out 10 micron particles) Note :- Each paper filter and woolen filter will be changed once in every month and upto 11 months
Membrane of capacity 250 Litre / hr
Carbon and Silica
Water flow meter (Reject / product)
230V AC Electromagnetic metering/Dosing pump for RO Plant
Multi port Valve for filter vessel as per existing in site
Taking up / down water heater (Geyser) of capacity 25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connection and hot and cold water connection, and including transportation to the contractor 's workshop for repair and and back to site, after repairing, general cleaning with suitable detergent and making fully serviceable and fixing back. in same location / position or new location all as directed. Note :- (a) Replacement of any un serviceable parts required for making the geyser serviceable shall be measured and paid for seperately as "supply only" under respective item of this schedule.
All as per item No 111.00 here in before but for geyser of capacity 50 ltrs.
Supply only stailnless steel inner tank suitable for 25 Ltrs geyser of any make /shape with any number of holes for fixing geyser assembly.
All as per item No 113.00 herein before but for geyser of capacity 50 ltrs.
Supply only syphon assembly of stainless steel 6 / 8 / 9 holes type suitable for 25 ltrs capacity geyser
All as per item No 115.00 here-in- before but for geyser of 50 ltrs capacity.
Supply only heating element 1000/1500/2000 watts capacity of any shape /type with rubber gasket ISI Marked
Supply only thermostat suitable to adjust the temperature from 0º C to 80º C all as directed ISI Marked.
Supply only neon indicator lamp of any shape / size / colour all as directed.
Supply only rubber gasket of thickness 5 mm for geyser assembly of 06/08/09 holes all as specified.
Supply only the bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape all as directed.
Supply and fixing 3 pin plug top 15 Amps, with back plate bakelite suitable for 230/240 volts AC supply all as directed.
Supply only rubber ring of existing size to the lower and upper housing of geyser, any make / size all as directed.
Supply only outer MS shell complete inluding top and bottom suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG all as directed.
All as per item No 124.00 here in before but for geyser of capacity 50 ltrs.
Taking down carefully old unserviceable stop valve /NRV/ Bip tap of any size / make and making good the disturbed surfaces complete all as specified and directed.
Supply and fixing angle stop valve, chromium plated, brass fancy type, screwed down, high pressure with crutch or butterfly handle screwed down , screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed complete all as specified and directed.
Supply and fixing bib cock without flange (foam flow), cast copper alloy chromium plated, fancy type, screwed for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
S&F as in repairs PVC connection 15mm bore 450mm long in any position with both end brass nut with inner threading and washer suitable for cold water connection complete all as directed .
All as Srl item No.129.00 here in before but for hot water connection
Taking down carefully old U/s sub main wiring of any type /size including conduit and conduit accessories and making good the disturbed surfaces all as directed. Note :- 3 run of cable shall be taken as one unit for measurement purposes
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm FRLS copper conductor cable PVC insulated multistranded and sheathed LT 1100 V grade drawn through and including non metallic rigid PVC conduit 20mm dia 2.00 mm thick ISI marked fixed on wall /floor etc with accessories duly connected with earth dolly complete all as specified and as directed. Note : (i) Cost of cutting chasing and making good to disturbed surface all as to match with the existing surface are deemed to be included in the quoted rate. (ii) 3 run of cable shall be taken as one unit for measurement purposes
Supply and fixing as in repairs single pole and neutral sheet metal enclosure with socket plug top 2 pin and earth complete with one single pole MCB 20 Amps all as directed.
Supply and fixing as in repair wireless addressable smoke detector with battery , testing button, LED & all mounting accessories for fixing complete all as specified and directed.
S&F as in repair wireless addressable electronic hooter with inbuilt transmitter cum red flasher with sounder & red ABS plastic enclousure , with back up facility in case of power failure complete all as specified and directed .
S&F as in repair wireless intellegent addressable manual call point (MCP) , break glass type with hammer complete all as specified and directed .
S&F as in repair wireless addressable main control panel with display & alarming sound with back up facility in case of power failure complete all as specified and directed.
M/s Rohit Construction Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .