Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹25.2 L+₹1.7 L (7.18%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹29.2 L+₹5.7 L (24.3%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹30.0 L+₹6.5 L (27.4%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹34.6 L+₹11.1 L (47.4%)Rejected-AOC 368 PHASE 4 SAS NAGAR MOHALI 160059 PB | S A S NAGAR | PUNJAB | 160059 | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
12 Sept 2022, 6:00 pmClosed
GE (AF) Chandigarh
GE (AF) Chandigarh PIN-160003
REPAIR TO WATER SUPPLY SERVICES IN MD ACCN AT SECTOR 28, 31 AND 47 CHANDIGARH UNDER GE (AF) CHANDIGARH
2022_MES_545679_1
GE (AF)/CHD/T-35/2022-23
Open Tender
Civil Works
Item Rate
183 days
Chandigarh
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE (AF) Chandigarh
₹64,000
Yes
4 Nov 2022
16 Aug 2022
14 Sept 2022
16 Aug 2022
12 Sept 2022
30 Aug 2022
16 Aug 2022 - 23 Aug 2022
Amount
BOQ UPLOADED ON 16 AUG 2022
Excavation in trenches in soft/ loose soil n. exc. 1.5 m wide and n. exc. 1.5 m deep for taking out/ laying/ re-laying of pipes and getting out complete all as specified and directed.
Excavation in trenches in hard standing/ road cutting n. exc. 1.50m in depth for repairs/ laying of CI/ GI/ DI/ HDPE pipe line and removing the rubbish outside MoD premises complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers n. exc. 25cm thick each complete all as specified and directed.
Removal of surplus soil to a distance n. exc. 50m away and depositing where directed at a level not exc. 1.5 above the starting point complete all as directed.
Dismantling and taking out GI pipe of following sizes from trenches/ walls/ ceilings/ floors etc. with all fittings such as bends, elbow and tees etc. complete all as specified and directed. Note: Excavation and earth work as required will be measured and paid for separately under appropriate item of this schedule.
15mm bore
20mm bore
25mm bore
Supplying, laying, jointing and testing medium grade GI pipe of following sizes inclusive of all fittings such as bends, Tees, unions, elbows, reducers and sockets etc. complete all as specified and directed. Note: Excavation and earth work will be measured and paid for separately
15mm bore
20mm bore
25mm bore
Supply & fixing in replacement gun metal globe/ gate valve with iron wheel handle screwed at both ends ISI marked suitable for GI pipe of following sizes complete all as specified and directed.
15mm bore
20mm bore
25mm bore
Cutting existing steel tubing of following sizes in position without taking down for alteration or additions (each cut measured) complete all as specified and directed.
15mm bore
20mm bore
25mm bore
Supply & fix in repair GI tee suitable for 20mm bore pipe complete all as specified and directed.
Supply & fix in repair GI tee suitable for 25mm bore pipe complete all as specified and directed.
Supply & fix in repair GI union suitable for 20mm bore pipe complete all as specified and directed.
Supply & fix in repair GI union suitable for 25mm bore pipe complete all as specified and directed.
Supply & fix in repair 100mm long GI nipple 15mm bore complete all as specified and directed.
Supply & fix in repair 100mm long GI nipple 20mm bore complete all as specified and directed.
Supply & fix in repair 100mm long GI nipple 25mm bore complete all as specified and directed.
Supply & fix in repair GI reducer of size 20/ 15mm bore complete all as specified and directed.
Supply & fix in repair GI reducer of size 25/ 20mm bore complete all as specified and directed.
Supply & fix in repair GI socket suitable for 15mm bore pipe complete all as specified and directed.
Supply & fix in repair GI socket suitable for 20mm bore pipe complete all as specified and directed.
Supply & fix in repair GI socket suitable for 25mm bore pipe complete all as specified and directed.
S&F in repairs 15mm bore straight plain brass ferrules heavy duty (or connecting screw), screwed both ends complete all as specified and directed.
S&F in repairs 25mm bore straight plain brass ferrules heavy duty (or connecting screw), screwed both ends complete all as specified and directed.
Supply and fixing in replacement high pressure PTMT ball valve with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20mm bore (Minimum weight 210g) complete all as specified and directed.
M&L for cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in mass concrete in making good to damaged portion of road/ hard standing complete all as specified and as directed.
Attending the complaint of water supply for leakage, pipe broken, line block, cleaning of pipe, float valve and all related to water supply find out the problems & rectifying the same day without affecting the services complete. Note: - (i) Contractor shall make arrangement for receiving the complaint round the clock. (ii) Complaint should be attended and rectified within one hour. (iii) Complaint attendee should have specific knowledge of water supply. (iv) Contractor will have to provide all tools & plant, vehicle & phone etc. required by the attendant and no extra payment will be allowed on this account.
Disconnecting electrically single phase 240 volt electric motor with pump upto 0.75 HP capacity, unbolting it and transporting to workshop, opening & taking out burnt copper winding, cleaning of startor slots, rewinding it with copper enameled wire of suitable gauge including insulating, varnishing material, replacement of damage ball bearing of suitable size, transporting it to the site and re-flexing to its original position and making electrical connection including testing complete all as directed.
Supply and fixing in replacement 4.00 sqmm flat twin core, 240 volt copper conductor wire as in service connection complete all as specified and directed.
SANJEEV ENTERPRISES
PARTAP ENGINEERING WORKS
R D Bansal
Baba Engineers and Contractors
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .