| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹146.3 CrAccepted-AOC | ₹146.3 Cr | L1 | Accepted-AOC Technically Qualified and L1 Bidder |
| 2 | L2₹166.0 CrRejected-AOC | ₹166.0 Cr | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹169.3 CrRejected-AOC | ₹169.3 Cr | L3 | Rejected-AOC L3 Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Does not meet clause No. 5 of Qualification Criteria of the section III of the Tender Document |
| 5 | Rejected-Technical | - | - | Rejected-Technical Does not meet clause No. 3.4.2(a) of Qualification Criteria of the section III of the Tender Document |
Tender Value
₹173.0 Cr
EMD Value
₹3.5 Cr
Closing Date
16 Aug 2021, 2:00 pmClosed
Chief Engineer, EAP, PWRD, Assam
O/o- The Chief Engineer, EAP, PWRD, Assam, ARRTI Campus, Fatasil Ambari, Guwahati-781025
A/RI-2 improvement and upgradation of Dhakuakhana Bitikur Telijan under ASRIP
2021_PWRD_22101_1
CE/ASRIP/09/2021/7 Dtd. 30/06/2021
Open Tender
Civil Works
900 days
Dhakuakhana
Please refer Tender documents.
9 documents required · 9 mandatory
₹10,000
Yes
Assam State Road Board
₹3.5 Cr
Yes
O/o- The Chief Engineer, EAP, PWRD, Assam
8 Jul 2022
3 Jul 2021
16 Aug 2021
3 Jul 2021
16 Aug 2021
3 Jul 2021
3 Jul 2021 - 15 Jul 2021
15 Jul 2021
Amount
Road Works Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications Clause No.201) a) Girth from 300 mm to 600 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications Clause No.201) b) Girth from 600 mm to 900 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications Clause No.201) c) Girth from 900 mm to 1800 mm
Cutting of Trees, including Cutting of Trunks, Branches and Removal (Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lead and lifts and earth/sand filling in the depression/pit created as per Technical specifications Clause No.201) d) Girth above 1800 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 300 mm to 600 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 600 mm to 900 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth from 900 mm to 1800 mm
Removal of stumps of trees left behind after cutting of trees by other agency with all lifts and lead and earth filling in the depression / pit as per Technical specifications Clause No.201 Girth above 1800 mm
Clearing and Grubbing Road Land. Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of roots of trees cut earlier and disposal of unserviceable materials, stacking of serviceable material to be used as directed by Engineer as per technical specification Clause No.201)
Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials to shown location, stacking serviceable and unserviceable materials separately, By mechanical means as per Technical specification clause No 202.) Bituminous courses
Dismantling of Flexible Pavements (Dismantling of flexible pavements and taking dismantled materials to construction camp, stacking serviceable and unserviceable materials separately for re-use as per additional Technical specification A-3, By mechanical means.as per drawing and technical specification) Granular courses
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead as per Technical specification Clause No.202 Cement Concrete (PCC and RCC) (M-15 & M-20)
Dismantling of Structures (Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, prestressed concrete, wood work, steel work, including Pools and plants (T&P) and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lift and lead.) Cement Concrete (Above M-20)
Removing all type of Hume pipe culverts above 900mm diaMetre including masonry works and stacking pipes at location shown by Engineer as per technical Specifications clause 202
Excavation in Soil using Hydraulic Excavator Tippers with disposal all lead and lifts. (Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, loading disposal of excavated earth with in all lifts and leads or for reuse if suitable for embankment/subgrade at other location). As per Clause.301.3 technical specification)
Excavation in Marshy Soil (Excavation for roadway in marshy soil with hydraulic excavator including cutting and loading in tippers and disposal with in all lifts and lead, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections, as per technical specification Clause .301.3)
Excavation in Ordinary Rock using Hydraulic Excavator and Tippers within all lifts and leads. (Excavation for roadway in ordinary rock with hydraulic excavator including cutting and loading in tippers, transporting to embankment site within all lift and lead, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross sections as per technical specification Clause .301.3)
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirements of Technical specifications Clause No.305
Construction of Embankment with materials deposited from roadway cutting (Construction of embankment with approved Material Deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of table 300-2 and as per technical specification Clause 305).
Construction of Subgrade/Median/Earthen Shoulders (Construction of sub-grade, Median and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 and Technical specification Clause 305 and 408)
Compacting original ground supporting sub-grade (Loosening and Recompacting of the ground upto a level of 500 mm below the sub-grade level, watered, graded and compacted in layers to meet requirement of table 300-2 for sub-grade construction. As per technical specification Clause 305)
Granular Sub-Base with Coarse Graded Material (Table: - 400- 1), (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per Technical specifications clause 401) (I) For Grading V Material
Granular Sub-Base by reuse of excavated Coarse Graded Material from existing road (Table:- 400- 1) ( Construction of granular sub-base by reuse of excavated non bituminous base and sub base roadway material from existing road , taking to plant area ,crushing to size and mixing suitable materials required to bring it to desired grading latter spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401 and Table 400-2 of Technical Specification and clause No. 401) (i)For Grading V Material
Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate as per Technical specification including premixing the Material with water at OMC in mechanical mix plant, carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.as per Technical specification clause No.406)
Prime Coat Providing and applying primer coat as per Technical specification clause 502 with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per spreading rate approved by Engineer.
Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.
Dense Bituminous Macadam Providing and laying dense bituminous macadam Grading II (19mm nominal aggregate size) using VG 30 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause .505 .
Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause 501.2 .1
Providing and laying Interlocking Concrete Block Pavement (ICBP) conforming to IS:15658-2006 including sand below block & Side packing M15 concrete with all lead and lift complete as per technical specification and as directed by Engineer In-Charge. 80mm thick interlocking precast blocks having compressive strength of 40N/sq.mm
Cast in Situ Cement Concrete M20 kerb with kerb laying machine, foundation concrete laid manually as per given drawing and Technical specifications Clause .409
Painting Two Coats on New Concrete Surfaces’ Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per ATS-2
Drain PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) as per Technical specification Clause 1704.3
Drain Reinforced cement Concrete in open foundation complete as per drawing & technical specifications RCC grade M20 using concrete mixture Section 2100
Drain Reinforcement in Foundation: Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and technical specifications Section 1600 TMT-IS 1786 (Fe-500 D)
Drain Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification Clause No.2706
Providing a Pipe Culvert for Access Road complete as per drawing and Technical Specification Section 2900
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway KiloMetre Stone (Second revision) 5th kilometre stone (precast)
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway KiloMetre Stone (Second revision) Ordinary KiloMetre stone (Precast)
Kilometre Stone: Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc.as per technical specification IRC: 8 -1980 Type Designs of Highway Kilometre Stone (Second revision) Hectometre stone (Precast
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause no 801.3 90 cm equilateral triangle
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause 801.3 60 cm equilateral triangle
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause no. 801.3 60 cm circular
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing 80 mm x 60 mm rectangular Clause No.801.3
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause no 801.3 60 cm x 45 cm rectangular
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and clause 801.3 60 cm x 60 cm square
Retro-Reflectorised Traffic Signs Providing and fixing of retro- reflectrorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause . 801.3 90 cm high octagon
Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectrorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing and Technical specification clause 801.3
Direction and Place Identification Signs with size more than 0.9 sqm size Board. Providing and erecting direction and place identification retro- reflectrorised sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing and Clause No.801.3
Overhead Signs of including Truss, Two Vertical Post, concrete foundation all complete Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectrorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in Technical specification clause 802.2 and 802.3 and installed as per Technical specification clause 802.6 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved drawing and plans and Technical specifications complete and Technical specification Clause No.802
Metal Beam Crash Barrier Type - A, “W” : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS : 1367 and IS : 1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x5 mm, 546 mm long complete as per Technical specification clause 811.3 complete job as per approved drawings.
Flexible Crash Barrier, Wire Rope Safety Barrier (Providing and erecting a wire rope safety barrier with vertical posts of medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50 m long 0.85 m above ground and 0.65 m below ground level, split at the bottom for better grip , embeded in M-15 grade cement concrete 450mm X 450mm X 450mm, 1.50m centre to centre with 4 horizontal steel wire rope 40mm dia and anchored at terminal posts 15m apart. Terminal posts to be embeded in M15 grade cement concrete foundation 2400 X 450 X 900mm (Depth), strengthen by a strut of Rs joists 100X75mm. 2m long at 450 inclination and a tie 100 X 8mm, 1.50m long at the bottom, all embeded in foundation concrete as per approved design and drawing rate excluding excavation and cement concrete.) as per clause no 811.4
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including Reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35. The finished surface to be level, uniform and free from streaks and holes as per Technical specification Clause No. 803.4
Boundary pillar Reinforced cement concrete M15 grade boundary pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting as per Clause No. 807
Cable Duct Across the Road Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC 98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC 98 - 2011 and approved drawings, Single Row for one utility service
Pedestrian Guard Rail: Tubular Steel Railing on Medium Weight steel channel (ISMC series) 100 mm x 50 mm (Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings and Technical Specification clause 809)
Road Stud with Lense Reflector Road Markers/Road Stud with Lense Reflector (Providing and fixing of road stud 100x 100 mm, die cast in aluminium, resistant to corrosive effect of salt and grit, fitted with lense reflectors, installed in concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm and bedded in a suitable bituminous grout or epoxy mortar, all as per BS 873 part 4:1973) and Technical specification Clause 804.
Supply & installation of solar street light proposed at Major & Minor Junction Location, Bus Bay & Bus Shelter Location as per drawing and Clause No. 12.4 of IRC SP 73 :2018 "Manual of Specifications and Standards for Two Laning of Highways with Paved Shoulder (Second Revision)
Construction of R.C.C Bus shelter at Village Portion as per drawing and Technical specifications Clause No. 12.6 of IRC SP 73 :2018 "Manual of Specifications and Standards for Two Laning of Highways with Paved Shoulder (Second Revision)
Cast in Situ Cement Concrete M 20 Kerb with Channel (Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete manually all complete as per Technical specification Clause 409)
Providing and laying of a PVC rain water pipe 100mm Dia as per drawing and Technical specifications Clause 309.3
Supply and Installation of 300 mm Solar Blinker. LED - 216 Solar Panel 30 Watt Battery - 12 AH Fitting, Fixing and all complete Job.
Box Culvert/Minor Bridge Plain/Reinforced cement concrete, in foundation complete as per drawing and technical specification including steel shuttering formwork and Technical specification Section 2100 RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Box Culvert/Minor Bridge Reinforced cement concrete, in sub structure complete as per drawing and technical specification Section.2200 and steel shuttering formwork RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Box Culvert/Minor Bridge Furnishing and Placing Reinforced/ Prestressed cement concrete in superstructure as per drawing and Technical Specification’ Section 2300 including steel shuttering formwork. RCC Grade M30 Using Batching Plant, Transit Mixer and Concrete Pump
Box Culvert/Minor Bridge Reinforcement in Foundation (Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in foundation complete as per drawing and Technical specifications Section 1600)
Box Culvert/Minor Bridge Reinforcement in Sub Structure (Supplying, fitting and placing TMT IS:1786 Fe500 D bar reinforcement in sub structure complete as per drawing and Technical specifications Section 1600)
Box Culvert/Minor Bridge Reinforcement in Super Structure Supplying, fitting and placing TMT conforming to IS:1786 Fe 500 D (reinforcement in super-structure including splicing complete as per drawing and technical specification Section 1600)
Box Culvert/Minor Bridge Plain cement concrete, in foundation complete as per drawing and Technical specification Clause 1704.3 including steel shuttering formwork. PCC Grade M15
Box Culvert/Minor Bridge Plain cement concrete, in foundation complete as per drawing and Technical specification 2507 including steel shuttering formwork. PCC Grade M20
Box Culvert/Minor Bridge Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutment, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification Section 2500
Box Culvert/Minor Bridge Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification Clause No 304, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. Depth upto 3 m
Box Culvert/Minor Bridge Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification Clause 2706
Box Culvert/Minor Bridge Backfilling behind abutment, wing wall and return wall complete as per drawings and Technical Specification as Per Appendix 6 of IRC78 :2014 "Standard Specifications and Code of Practice for Road Bridges"
Box Culvert/Minor Bridge Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications Section 2500
Box Culvert/Minor Bridge Stone/Boulder Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Section 2500
Box Culvert/Minor Bridge Providing and laying Stone/Boulder apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification Section 2500
Box Culvert/Minor Bridge Rigid Apron: -Providing and laying Flooring complete as per drawing and Technical specifications Section 2500 laid over cement concrete bedding. Rubble stone laid in cement mortar 1:3
Box Culvert/Minor Bridge Provision of reinforced cement concrete crash barrier (New Jersey Type) on structure, constructed with M - 40 grade concrete with HYSD reinforcement conforming to IRC:21, including 50mm dia railing with fixtures and installed as per approved drawings and at locations as directed by the Engineer. As per Technical specification Clause 2703.3 and Clause 811.2 & Clause No. 109.6. of IRC: 5 -2015 Standard Specifications and Code of Practice for Road Bridges Section- I General Features of Design
Box Culvert/Minor Bridge Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause 2702.
Box Culvert/Minor Bridge Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause 501.2 .1
Box Culvert/Minor Bridge Tack Coat Providing and applying tack coat with bitumen emulsion as per Technical specifications clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.
Box Culvert/Minor Bridge Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per Technical specification as per ATS-2
Protection works Providing and laying Stone/Boulder Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specification Section 2500
Protection works Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification and Section 2500
Protection works Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification Clause No.2100 including steel shuttering formwork. For Chute Drain
Protection works Gabion Structure for Erosion Control, River Training Works and Protection works (Providing and constructing gabion structures for erosion control, river training works and protection works with wire crates of size 2 m x 1 m x 0.3 m each divided into 1m compartments by cross netting, made from 4 mm galvanised steel wire@ 32Kgs per 10Sqm having minimum tensile strength of 300Mpa conforming to IS:280 and galvanizing coating conforming to IS:4826, woven into meshes with double twist, mesh size not exceeding to 100mmX100mm , filled with boulders at least dimension of 200mm , all loose ends to be tied with 4mm galvanized steel wire.) as per IRC SP 116:2018 Guidelines for Design and Installation of Gabion Structures
Protection works Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surfaces behind the abutment, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification Section 2500 Retaining Wall
Protection works Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) as per Technical specification Clause 307.
Protection works Supplying, filling and laying in loose with Geotextile bags of Type-A (1.30x0.70 M) made of Geo textile non-woven fabric sheets of 400 GSM manufactured from polyester/ polypropylene conforming to relevant ISO standard filled with specified sand/ silt from flood plain or adjacent char within a distance of 90 m of the work site including excavation, filling Geo bags with sand weighing 126.00 kg after filling, stitching the mouth of the filled bags with polypropylene or polyester complete as per technical specifications and as directed. as per IRC SP 59 :2019 Guidelines for use of Geosynthetics in Road Pavements and Associated Works
Protection works Supply, Stitching and Laying of Non-woven Geo textile Fabric sheet of 400 gsm as per Clause No 702
Repair and Maintenance of Bridges Replacement of Expansion Joints complete as per drawings and Section 2800 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), IRC: SP: 35 Guidelines for Inspection and Maintenance of Bridges and IRC SP 52-Bridge Inspector Reference Manual
Repair and Maintenance of Bridges PCC M15 Grade levelling course below approach slab complete as per drawing and Technical specification Clause No 2704
Repair and Maintenance of Bridges Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification and Clause No.2704 TMT-IS 1786 (Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal steel/ Shyam steel or equivalent)
Repair and Maintenance of Bridges Tack coat Providing and applying tack coat with bitumen emulsion as per Technical specification clause 503 by using emulsion pressure distributor on the prepared bituminous surface cleaned with mechanical broom at rate of spread approved by Engineer.
Repair and Maintenance of Bridges Bituminous Concrete Providing and laying bituminous concrete Grading I (13mm nominal aggregate size) using PMB 70 grade bitumen with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using materials as per mix design, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, compacting to achieve the desired compaction and complete in all respects as per Technical specification clause 501.2 .1
Repair and Maintenance of Bridges Mastic Asphalt (Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-29( binder having penetration as (15+/- 5) at 25 deg. centigrade), prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing anti-skid surface with bitumen pre coated fine grained hard stone ships of 13.2mm nominal size at the rate of .005cum per 10 sqm. and at an approximate spacing of 10 cm centre to centre in both directions, pressed into surface when the temperature of surfaces not less than 1000C, protruding 1mm to 4mm over mastic surface, all complete as per Technical specification Clause No.516
Repair and Maintenance of Bridges Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications and Section 2500
Repair and Maintenance of Bridges Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification Section 2500
Repair and Maintenance of Bridges Guniting concrete surface with cement mortar applied with compressor after cleaning surface and spraying with epoxy complete as per Technical specification Clause 2807
Repair and Maintenance of Bridges Applying epoxy mortar over leached, honey combed and spalled concrete surface and exposed steel reinforcement complete as per Technical specification and Clause No 2803 Technical specification Clause No.2804
Repair and Maintenance of Bridges Clearing Grass and Removal of Rubbish (clearing grass and removal of rubbish upto distance of 50m outside the periphery of the area.) as per Technical specification Clause .201
Repair and Maintenance of Bridges Painting Two Coats on New Concrete Surfaces’ Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces as per Technical specification as per ATS-2
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Near all hot mix plant locations approved by the Engineer as per Technical specification clause 111
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. Construction sites near sensitive locations as per Technical specification clause 111
Environment Management Cost Ambient air quality monitoring along the project road for particulate matter (PM2.5 and PM10), sulphur dioxide (SO2), oxides of nitrogen (NOX); and carbon monoxides (CO) using standard analysis technique in accordance with the National Ambient Air Quality Standards formulated by MoEF&CC and the World Bank (IFC) Air Quality. At 1 location during operation stage where monitoring had been done during construction stage as per Technical specification clause 111
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. At equipment yards/ Hot mix plants/ Construction Camps as per Technical specification clause 111
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. Near known nesting sites - as directed by the Engineer as per Technical specification clause 111
Environment Management Cost Sound Pressure Level (SPL) measurements along the project road using standard analysis technique in accordance with the National Ambient Air Quality Standards in respect of noise formulated by MoEF&CC and the World Bank (IFC) Air Quality. During Operation Stage as directed by the Engineer as per Technical specification clause 111
Environment Management Cost Water Quality Testing for paraMetres as per IS: 10500-2012 along the road in accordance with CPCB norms Surface Water Quality testing during Construction Stage as per Technical specification clause 111
Environment Management Cost Water Quality Testing for paraMetres as per IS: 10500-2012 along the road in accordance with CPCB norms Discharge Water Quality testing during Operation Stage as per Technical specification clause 111
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Construction stage at productive agricultural lands abutting traffic detours and traffic diversions, to be identified by the Engineer as per Technical specification clause 111
Environment Management Cost Soil Quality Testing along the project road in accordance with CPCB norms During Operation stage at accident/spill locations involving bulk transport carrying hazardous material. as per Technical specification clause 111
Environment Management Cost Turfing with Sods (Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the engineer including preparation of ground, fetching of rods and watering) 5 m width turfing on outer side of ponds located at chainage CH. 4+200, 6+000, 16+400, 17+300,17+400,20+600,23+700,27+550 as per Technical specification clause 111 and 307
Environment Management Cost Surface Drains in Soil (Construction of unlined surface drains of average cross-sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of Technical specification clause 301 and 309. Excavated material to be used in embankment within a lead of 50m (Average lead 25m) Construction of surface drains on outer side of ponds located at chainage 4+200, 6+000, 16+400, 17+300,17+400,20+600,23+700,27+550
Environment Management Cost Oil interceptors at parking/ servicing of construction vehicles as per Technical specification clause 111
Environment Management Cost Provision of Noise barrier at sensitive areas like schools and hospitals. The noise barriers of hollow brick wall/ reinforced concrete panels with height of 3.5m. School location: 0+700 (R), 3+120 (R) as per clause 111
Provisinal Sum for road facilities and Amenities
DRAIPL - JKM JV
SGCCL-ANPL
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid