Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.2 LAccepted-AOC NO 229 ANGAPPAN STREET MITTANAMALAI AVADI IAF CHENNAI 600 055 | CHENNAI | CHENNAI | TAMIL NADU | 600055 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.8 L+₹57,281 (2.98%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Not Being L1 |
Tender Value
Refer Docs
EMD Value
₹42,500
Closing Date
28 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Avadi
Garrison Engineer, Muthapudupet, Avadi, Chennai 600 055
SPL REPAIRS/REPLACEMENT OF BER COOLING/HEATING APPLIANCES AND PROVISION OF INTERNAL SERVICES FOR FIXING CERTAIN TECHNICAL EQUIPMENT AT AF STN AVADI
2023_MES_629749_1
8147
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer, Muthapudupet, Avadi, Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Avadi
₹42,500
24 Jan 2024
25 Nov 2023
4 Jan 2024
25 Nov 2023
28 Dec 2023
9 Dec 2023
Amount
Disconnecting electric supply from electric sources, taking down Split type air conditioner 1.5TR capacity with voltage stabilizers without damaging any other eqpts and making good and matching with existing surface complete and incl transportation to MES store yard GE Avadi with all acceossries.
All as per item No1 here-in-before but Split type AC 3.0 TR capacity
All as per item No1 here-in-before but Window type AC 1.50 TR capacity
Supply and Install Hi wall split Air Conditioner 1.50 TR capacity with Indoor, outdoor units complete cordless remote control unit and with in-built ioniser and plasma filter for better indoor air quality with minium 3 star rating and EER 3.2 ( Copper Condenser Coil)
Supply and fixing of GI powder coated brackets 16SWG for fixing of split Acs out door unit and including grouting with suitable size fastners complete.
Supply and fix voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input varition between 90V to 260V with out put voltage stablized at 230v with accuracy of +/- 2.5% and capacity 4KVA
Supply and fix copper tubing set 1/4" and 1/2" suitable for Split AC including PUF insulation and connected accessories, fixcing for outdoor unit for user requirement complete all as directed by eng-in-charge
Supply, installation, commissioning of water cooler partially stainless steel electric driven (Single Phase) having approx storage and nominal cooling capacity of 150/ 150 litre
Supply, installation, commissioning of Water purifier 50LPH commercial UV+RO water purifier Plant
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out soft / loose soil for laying cables / pipes / erection of poles etc all as specified and as directed.
Returning filling in soil including spreading leveling watering well ramming in layers not exceeding 25 cm each all as specified and as directed.
Laying in trenches Fine Excavated Dry Soil including spreading / leveling, cushioning for underground cables all as specified and as directed.
Supply and laying of common burnt clay building bricks, sub class B of size 230x115x75mm for cable protection all as specified and as directed.
Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade laying in trench,on pole,on wall or on ceiling etc complete all as specified and as directed of Size 3.5 Core, 70 Sqmm. (NOTE : Earth work including excavation ,returning Filling,removing,soil coushioning,brick covering for mechanical protection of cable etc will be measured and paid separately under respective items of schedule)
All as per Sl Item No. 15 here-in-before but of size 4 Core, 25 Sqmm
Material and labour for GI tubing light grade for cable protection laid in trenches in road crossing or fixed to wall/Pole of size 80 mm dia complete all as specified and as directed.
Supply and fixing of MCCB, 4 Pole 415 Volts,Adjustable type, 160 Amps with breaking capacity 36 KA for mounting in existing LT Panel complete all as specified and as directed .
Supply and fixing switch socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete with MS terminal box and laminated hylam sheet with fitting accessories complete all as specified. (Through Submain wiring)
Supply and fixing Power / Sub-main wiring with PVC insulated unsheathed, FRLSH ,1100 volts, grade multistranded copper conductor, two runs of single core 6 sqmm conforming to IS-694, drawn through and including suitable dia PVC Casing caping, and casing caping accessories alongwith one run 6 sqmm PVC insulated single core multistranded copper conductor cable (green) as earth continuity conductor fixed in walls/floors/Wooden board or working table with suitable clamps and connected accessories and connecting to common earth dolly complete all as specified and as directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6-32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified.
Supply and fixing Load line MCB DB TP&N 4 way, vertical, double door, powder coated, 415 volts, AC, 50Hz, IP 54 protected, fixed on wall semi flush with provision for FP MCCB 100 Amps as incomer and SP MCBs 40 / 63 Amps as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming MCCB and Outgoing MCB measured separately relevent items.
Supply and fixing MCB DB SPN 8 way, double door, powder coated, 240 volts, AC, 50Hz, IP 43 protected, with provision for MCB double pole as incomer and SP MCBs as outgoing with tinned copper bus bar, neutral link, earth link and connecting up complete all as specified and as directed. Note : Incoming and Outgoing MCB measured separately relevent items.
Material and labour for earth continuity conductor or main earthing lead fixed to valve on batten or recess or chases or burried in ground or drawing in conduit or any other situation for loop earthing etc as reqd 4 mm dia galvanized steel wire all as specified and directed by Engr-in-Charge
Material and labour for Earthing complete with galvanised iron earth plate electrode 600mm X 600mm X 6mm thick, with and including earthing of 4mm dia GI wire protected by 15mm dia GI pipe light grade upto a length of 7.5m. The plate shall be buried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of the earth plate at a depth not less than 1.5 metres below ground level, connected to earth lead as described here-in-before by means of bolts, nuts, washers and checknuts made out of galvanised iron or mild steel, earthing lead protected by as described here-in-before and connected to main switch board or main control board or electric pole all as shown on electrical plate No.3 of MES Sch Part-I including necessary earth work and excavation in any type of soil, plain cement concrete 1:3:6, type C1 chamber, reinforced cement concrete cover slab with locking arrangement and handle of 10mm dia MS round bars 450mm long, 1:2:4 type B1, 50mm thick with 8mm dia TMT bars at 140mm centre to centre both ways, GI pipe of bore 20mm medium grade for watering with funnel, wiremesh, salt, charcoal, lugs including testing complete all as specified and as directed.
PSK Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .