| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹45.3 L+₹30,935 (0.69%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance BEING NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
4 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE U
HQ CWE U Delhi Cantt 110010
REPAIR REPLACEMENT OF SERVO CONTROLLED VOLTAGE STABILIZER AND ARD SYSTEM FOR LIFT IN VARIOUS LOCATIONS UNDER GE U P AND M DELHI CANTT 10
2020_MES_373507_1
89035/CWE(U)/D-13/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
Delhi Cantt
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
GE U PLANT AND MACHINARY
₹1.1 L
Yes
16 Nov 2020
4 Sept 2020
6 Nov 2020
4 Sept 2020
4 Nov 2020
20 Oct 2020
60 days
Amount
Taking down and Supply, fixing, testing and commissioning ARD 1.5KVA (Automatic Rescue Device) with panel and including necessary internal wiring work, suitable for Johnson make lifts at Arjan Vihar(block No:- 11A,11B,13B,34 & 37, total 05 Nos lift) & Manekshaw Marg (Block NO :-8 to 13, total 06 Nos including ARD batteries of capacity 12V, 7AH - 04 Nos. The battery shall be such that minimum three rescue operation can be performed without recharging as per site position for the 8 passengers lift complete all as specified and directed.
Taking down and Supply, fixing, testing and commissioning ARD 1.5KVA (Automatic Rescue Device) with panel and including necessary internal wiring work, suitable for OTIS make lifts at Arjan Vihar (block No. - 1 to 5,7,9,& 12A), Engineer Offrs Mess (Block No. - II), Manekshaw Marg (Block No. 62) & S P Marg (Block No. 3,13,20,22 & 24) including ARD batteries of capacity 12V, 7AH - 04 Nos the battery shall be such that minimum three rescue operation can be performed without recharging as per site position for the 8 passengers lift complete all as specified and directed .
Taking down and Supply, fixing, testing and commissioning ARD 1.5KVA (Automatic Rescue Device) with panel and including necessary internal wiring work, suitable for Indofuji make lifts at Engineer officer Mess (Block No. - III & 505 ABW NBC Building) Total 02 Nos lift, including ARD batteries of capacity 12V, 7AH - 04 Nos the battery shall be such that minimum three rescue operation can be performed without recharging as per site position for the 8 passengers lift complete all as specified and directed.
Supply, fixing and commissioning of wiring work from ARD to control panel of cable size 10 sqmm 4 core PVC insulated, unsheathed 1100 Volts, grade multistranded copper conductor cable in proper color coding including all necessary connections complete all as specified and directed.
Taking down and Repair/replacement of unserviceable parts ARD 1.5KVA (Automatic Rescue Device) with Card and including necessary internal wiring work, suitable for Thyssenkrupp ,Johnson , Otis make lifts at Arjan Vihar (block No:-3,4,6,8,10,14,12B, 19A,19B,20A,20B 21,22 total 13 Nos lifts) & Manekshaw Marg (block NO:- 63 total 01 No) passenger lift as per site position for the 8 passengers lift complete all as specified and directed . Note:- (i) Spares parts if required shall be measured & paid separately as ‘supply only’ under relevant items. (ii) Labour charge for ‘supply only’ materials are deemed to be included in the quoted rate.
Supply only ARD Card complete all as specified and directed.
Supply only 12V, 7AH Lead Acid batteries complete all as specified and directed.
Supply only connectors (male & female) for ARD complete all as specified and directed.
Taking down old unserviceable Hooters of 0.5 Km range , rechargible battery speaker & PCB card & complete wiring & supply & fixing with new Hooters, rechargible battery speaker & PCB card & complete wiring for lifts installed at Arjan Vihar (Block No 1 to 10, 11A,11B,12A,12B,13A,13B,14,,19A,19B,20A,20B,21,22,23,28,31,34 &37 total 28 Nos & Engr officer Mess Block-II & III total 02 Nos & 505 ABW Sansadhan Complex & NBC Building total 02 Nos.complete all as specified and directed.
Note : The work for item No 1 to 6 shall be carried out through respective OEM of existing make of lifts i.e., Johnson, OTIS, Thyssen Krupp, ECE, Indofuji only. (As the case may be)
Servicing of servo voltage stablizer of capacity 30 KVA installed at Arjan Vihar(Block No-15,16,17,25,26,27,28,29,30,32,33,35,11A,11B,13B,12B,14,34, 37,19B,20A,20B,21,22,23 & 31 = Total 26 Nos) & Manekshaw Marg (block No:- 56,57,58,59,60,61,62,63,64,8,9,10,11,12 = Total 14 Nos )for lift by disconnecting of all electrical connections of stabilizer and check the auto/manual function of stabilizer, to be check the oil level, oil seals leakage if any, check all volt meters and amp meter working condition or not, Taking out top cover of stabilizer for replacing defective parts/items clean the dust by air blower, check the neutral and earthing connections properly or not, to be done properly, to be check the all nut bolts tightining. and refixing, the same in existing location, and re connect all the incoming/outgoing cables properly including testing and commissioning complete all as specified and as directed.
Notes:- (i) Spares parts if required shall be measured & paid separately as "Supply only" under relevant items. (ii) Labour charge for "Supply only" materials are deemed to be included in the quoted rate. (iii) Specification for "Supply only" items shall be all as per existing item. (iv) Makes for "Supply only" items shall be all as per existing OEM.
Supply only electronic servo card complete all as specified and directed.
Supply only Ampere meter with C.T (Digital/analog) including necessary connection controlling switches complete (suitable size of shape) complete all as specified and directed.
Supply only voltmeter 0 to 440 volts flush type including necessary connection controlling switches complete (suitable size of shape) complete all as specified and directed.
Supply only Servo motor 3 K.G. torque single phase complete all as specified and directed.
Supply only Rotary switch 5 Amp for R. Y. B phase complete all as specified and directed.
Supply only trigger transformer complete all as specified and directed.
Supply only Port meter complete all as specified and directed
Supply only Auto manual switch complete all as specified and directed.
Supply only P.C.B Holder complete all as specified and directed.
Supply only Contractor strip complete all as specified and directed.
Supply only Indicator light complete all as specified and directed.
Supply only dimmer coil 60 amp rewinding complete all as specified and directed.
Supply only Main Transformer 30 KVA complete all as specified and directed.
M/s Dhapola Elevator and Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .