Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.9 CrAccepted-AOC | ₹7.9 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹8.0 Cr+₹15.2 L (1.92%)Rejected-Finance | ₹8.0 Cr+₹15.2 L (1.92%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹8.1 Cr+₹22.6 L (2.87%)Rejected-Finance | ₹8.1 Cr+₹22.6 L (2.87%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹8.2 Cr+₹30.6 L (3.88%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹8.2 Cr+₹30.6 L (3.88%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹8.6 Cr+₹73.7 L (9.36%)Rejected-Finance | ₹8.6 Cr+₹73.7 L (9.36%) | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹8.0 Cr
EMD Value
₹7.3 L
Closing Date
22 Jul 2021, 6:00 pmClosed
CE (AF) WAC PALAM
HQ CE (AF) WAC PALAM DELHI CANTT-10
PROVN OF PRPAID ELECTRIC METER FOR AF STATION UNDER GE (AF) SUBROTO PARK
2021_MES_449314_1
CEWAC/PAL/T-09/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) SUBROTO PARK
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE (AF) SUBROTO PARK
₹7.3 L
Yes
21 Oct 2021
10 Jun 2021
23 Jul 2021
10 Jun 2021
22 Jul 2021
13 Jul 2021
10 Jun 2021 - 25 Jun 2021
Amount
Supply, Installation, testing and commisioning of main data base cum vending server (Capacity 25000 upgradable to 1 Lakh meters data) in existing room for operating, functioning, token encryption for electric prepaid energy meter vending system comprising of server for data base, App, Web, standby data base, monitoring and management incld desktop for monitoring/ management, primary and secondary firewall, switch duly intsalled on floor mounted rack of suitable size all as specified and directed by Engr-in-Charge. Server shall comprises of following minimum hardware and software requirements :- (a) Server App :- Window 2016 (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM , 500GB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC), Gigabit Ethernet Network) (b) Server Web:- Window 2016 (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM, 500GB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC), Gigabit Ethernet Network). (c) Server Data base and stand by : Centos (OS software version 7) (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM, 1TB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC) 200 GB SSD, Gigabit Ethernet Network). The separarte server of same specification ios required as stand by. (d) Sever monitoring : Window 2016 (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM , 500GB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC), Gigabit Ethernet Network)
(e) Sever management : Window 2016 (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM , 500GB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC), Gigabit Ethernet Network) (f) Desktop-Standard CPU with monitor and accessaries:- Processor :Intel i5 core ,Windows 10 operating system, Memory: 16GB RAM , HDD: 1 TB HDD, Network Interface Card : 01 Nos, cordless Keyboard/Mouse and LED Monitor 15" complete. (g) Primary Firewall (Comapatible for VPN connectivity). Fortinet – IP Sec Site to site VPN feature. (h) Secondary Firewall. Fortinet– IP Sec Site to site VPN feature. (j) Switch. Dlink Link/Cisco , 16 port, 01 Gbps speed Unmanaged, Rack mounting Switch.
(k) Rack Space made of glass & CRCA sheet as required. One nos Quarter Rack dynamic 42 U Rack, 800Wx1000L mm (l) ROK with Licenses Windows 2016 . 5 Nos. (m) Networking wiring shall be carried out with CAT 7 cable (n) Data center requirements. Power backup-UPS (Capacity 30 minutes, 5.5 KVA single Phase with 16 nos batteries, 180 Ah dry type Li - ion) (o) Anti virus for system. Qty 5 Nos (Quick Heal Server addition with 5 years validity) (p) SSL certificate and Domain . One SSL certificate (This will be provided by contrcator/OEM on the name of department) (q) CERT certificate for server
Supply, Installation, commisioning of Disaster Recovery (DR Site) data base and vending server (Capacity 25000 upgradable to 1 Lakh meters data) in existing for operating, functiong, tocken encryption for electric meter vending comprising of server for data base, App, Web, primary firewall, switch duly intsalled on floor mounted rack of suitable size all as directed. The cost shall included for all necessary server software, windows, vending software, 3 phase power back up (UPS) for 30 min, anti-virus, licences, security certifications and integration of software amongst server, manufacturer software and meters complete all as specified and directed by Engr-in-Charge. Server shall comprises of following minimum hardware and software requirements :- (a) Server App and web :- Window 2016 (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM , 500GB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC),Gigabit Ethernet Network)
(b) Server Data Base and stand by:- Centos (OS software sever 7) (Also comprises of Intel Platform, 4 Cores, 2.4 GHz processor 16GB ECC RAM, 1TB HDD, 7.2K RPM (RAID-1), Battery Backed Write Cache(BBWC) 200 GB SSD, Gigabit Ethernet Network). The separarte server of same specification ios required as stand by. (c) Desktop-Standard CPU with monitor and accessaries:- Processor :Intel i5 core ,Windows 10 operating system, Memory: 16GB RAM , HDD: 1 TB HDD, Network Interface Card : 01 Nos, cordless Keyboard/ Mouse and LED Monitor 15" complete. (d) Primary Firewall (Comapatible for VPN connectivity). Fortinet – IP Sec Site to site VPN feature. (e) Secondary Firewall. Fortinet– IP Sec Site to site VPN feature. (f) Switch. Dlink Link/Cisco , 16 port, 01 Gbps speed Unmanaged, Rack mounting Switch. (g) Rack Space made of glass & CRCA sheet as required. Quarter Rack dynamic 42 U Rack, 800Wx1000Lmm (h) ROK with Licenses Windows 2016 . 4 Nos (j) Networking wiring shall be carried out with CAT 7 cable (k) Data center requirements. Power backup-UPS (Capacity 30 minutes, 5.5 KVA single Phase with with 16 nos batteries, 180 Ah dry type Li - ion) (l) Anti virus for system. Qty 2 Nos (Quick Heal Server addition with 5 years validity)
Note: For Sr no 1 and 2 above, quoted Rates are deemed to include (a). provn of one number of internet lease line (100 mbps and above) in the name of GE (AF)Subrato park , for connecting main and DR server. The initial and Monthly charges of rent for lease line will be paid by contractor till completion certificate is issued, after that it will be paid by Deptt. (b). Any other requirement of hardware/software which is not mentioned specifically but required to make the system functional (c) The work shall be executed by OEM of meter (d) Payment gateway in the server shall be responsibility of contractor.A three party agreement shall be held to make the gateway functional.Three parties shall include department,OEM and concern bank.
(e) contractor shall install software developed by manufacturer of meters in system and develop the app so that consumer can recharge prepaid meter through mobile apps, debit/credit card and net banking. The feeding of generated code in display unit through blue tooth or typing in display unit. Software shall have provision of generating refund to consumer in case of posting out and contrator shall provide physical Token Based Authentication Tool as keys to Deptt with specific rights of operating system and fixing tariff slab per unit of electricity in meter. (f) system shall be capable of generating reports in the format all as directed by Engineer-in Charge
Supply, installation, testing & commissioning of 3 Phase, 4 Wire, Dual Source, Pre-paid Energy Meters with PLSI sensing , IS - 15884 Marked in existing Meter Board / Floor Panels with Pre Payment capacitive touch Key pad,Bluetooth based Digital having current range 10-60Amp, 415V, acucuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature to sense the DG Mode through PLSI, dual source registration with respect to Grid as well as DG supply (wireless, without DCU USB, Pendrive & Sim, no other extra equipent required for dual sense, meter it self capable for dual sensing) and dynamic load allocation facility from Grid and DG, capable to define 4 tariff slabs, happy hour & holiday definition complete all as specified and directed. Area wise quantities are as under:- (Subroto Park :- 185, 56 ASP, AF :-24, MCC AF Station :- 7, 25 Wing Rajokri : - 18, AF Station Palam :-275) Total :-509 Nos
Supply, installation, testing & commissioning of 1 Phase, 2 Wire, Dual Source, Pre-paid Energy Meters with PLSI sensing, BIS 15884 Marked in existing Meter Board / Floor Panels with Pre Payment capacitive touch Key pad,Bluetooth, based Digital having current range 05-60Amp, 240V, acucuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature to sense the DG Mode through PLSI, dual source registration with respect to Grid as well as DG supply (wireless, without DCU USB, Pendrive & Sim, no other extra equipent required for dual sense, meter it self capable for dual sensing) and dynamic load allocation facility from Grid and DG, capable to define 4 tariff slabs, happy hour & holiday definition complete all as specified and directed. Area wise quantities are as under:-(Subroto Park :- 772, 56 ASP, AF :- 248, MCC AF Station :- 194, 25 Wing Rajokri :- 806, AF Station Palam :- 1977) Total :-3997 Nos Note for Item Nos 3 & 4:- Quoted rates are deemed tobe included uncoditional 10 year free replacement for prepaid meters.
Provision of the software for prepaid meters shall be of same OEM and developed in India only (Third party software is not acceptable) window based application for automatic meter reading (AMR) and configuration of meters and modems. It shall have interactive user interface for meter data viewing and report generation for effective data management and automatic meter data export facility, along with CMRI (Meter reading instrument) complete all as specified and directed by Engineer -In-Charge.
Provision of infrastructure for Vending system like computer PC desktop with processor i7 intel core, 16-GB RAM, hard disk 1 TB, 1-CD/DVD combo drive R/W type, 4-USB Port including 15" LED monitor, video card, keyboard, cordless mouse and licensed Operating system ( Window10), latest microsoft office package as on date, including antivirus (Quick Heal Server addition with 5 year validity), along with 1kVA capacity, single phase,online UPS with minimum 30 minutes backup all as specified. Area wise quantities are as under:- (Subroto Park :-2, 56 ASP, AF :- 1 MCC AF Station :- 1, 25 Wing Rajokri :- 1, AF Station Palam :- 1) Total:-6Nos
Supply and installation of wireless Report Laser Printer for print, copy, scan, with 12 pages per minute capacity, 600 x 600 dpi with HP, REt, 1200 dpi effective output quality (600 x 600 x 2 dpi with REt, with duty cycle 3,000 single-sided pages per month for report printing complete as required and all as specified. Area wise quantities are as under:- (Subroto Park :- 2, 56 ASP, AF :- 1 MCC AF Station :- 1, 25 Wing Rajokri :- 1, AF Station Palam :- 1) Total :-6 Nos
Supply of Impact token printer min 58 mm with serial/USB port having Thermal Receipt Printer Launch, High Speed Printing DoT matrix POS, complete all as specified and directed. Area wise quantities are as under:- (Subroto Park :- 2, 56 ASP, AF :- 1 MCC AF Station :- 1, 25 Wing Rajokri :- 1, AF Station Palam :- 1) Total :- 6 Nos
Supply and installation of 50 inch LED Screen with supporting of HDMI, VGA, ethernet port for Monitoring the whole system at server room and mounting wall with bracket and nutblots including necessary electrical wiring and connections from server, switch, sockets etc at Subroto Park all as specified and directed by Engr -in- Charge.
M&L for uploading of datas for implementaion of vending system through server after collecting data from meters, mapping of consumers, feeding data in vending station and server complete all as specified and directed by Engr-In-Charge.
Supply, testing, laying of 6 core control cable to connect meter to Parallel Home Display split Unit for remote access of data / operation including two cable end connectors (RJ-11), punching complete all as specified and as required. Area wise quantities are as under:- (Subroto Park :- 1800 RM, 56 ASP, AF :- 1750 RM, MCC AF Station :- 43780 RM, 25 Wing Rajokri :- 34000 RM, AF Station Palam :- 3296 RM) Total :- 84626 RM
Supply and fixing 25 mm dia medium grade, ISI Marked PVC conduit along with accessories laid on surface all as directed and specified. Area wise quantities are as under:- (Subroto Park :- 600 RM, 56 ASP, AF :- 8000 RM, MCC AF Station :- 15000 RM, 25 Wing Rajokri :- 6000 RM, AF Station Palam :- 16000 RM) Total :- 45600 RM
Supplying and fixing of medium class casing & capping size (20mm* 12mm) double lock type , alongwith accessories on the surface all as directed and specified. Area wise quantities are as under:- (Subroto Park :- 900 RM, 56 ASP, AF:- 2000 RM, MCC AF Station :- 2000 RM, 25 Wing Rajokri :- 2000 RM, AF Station Palam :- 5000 RM) Total :- 11900 RM
S&F sub main wiring with 1100 volt grade IS -694 Marked,with two run single core 10 Sqmm PVC insulated, unsheathed stranded copper FRLS conductor, drawn in conduit/ casing capping including 10 Sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed NOTE:-(i) Two number cable and one number earth wire shall be measured together as one unit length). (ii) The conduit/ casing capping shall be measured and paid separatly.
S&F sub main wiring with 1100 volt grade IS -694 Marked,with two run single core 06 Sqmm PVC insulated, unsheathed stranded copper FRLS conductor, drawn in conduit/ casing capping including 06 Sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed NOTE:-(i) Two number cable and one number earth wire shall be measured together as one unit length. (ii) The conduit/ casing capping shall be measured and paid separatly.
S&F sub main wiring with 1100 volt grade IS -694 Marked,with two run single core 04 Sqmm PVC insulated, unsheathed stranded copper FRLS conductor, drawn in conduit/ casing capping including 04 Sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed NOTE:- (i) Two number cable and one number earth wire shall be measured together as one unit length). (ii) The conduit/ casing capping shall be measured and paid separatly.
S&F sub main wiring with 1100 volt grade IS -694 Marked,with two run single core 2.5 Sqmm PVC insulated, unsheathed stranded copper FRLS conductor, drawn in conduit/ casing capping including 2.5 Sqmm copper stranded conductor PVC insulated FRLS earth wire connected to main board complete all as specified and directed NOTE:-(i) Two number cable and one number earth wire shall be measured together as one unit length. (ii) The conduit/ casing capping shall be measured and paid separatly.
S&F of MCB Triple pole and neutral 40 Amps working on 415 volts 50 Hz AC supply,10 KA, C series.complete all as specified and directed. Area wise quantities are as under:- (Subroto Park :- 130, 56 ASP, AF :-10, MCC AF Station :- 3, 25 Wing Rajokri :- 10, AF Station Palam :- 200) Total :- 353 Nos
S&F of MCB Single pole and neutral 40 Amps working on 240 volts 50 Hz AC supply,10 KA, C series.complete all as specified and directed. Area wise quantities are as under:- (Subroto Par :- 600, 56 ASP, AF :- 180, MCC AF Station :- 125, 25 Wing Rajokri :- 600, AF Station Palam :- 1500) Total :- 3005 Nos
Taking down old existing single/ three phase meters carefully noting down meter last reading for handing over to respective BSOs and depositing existing old meters to respective BSOs.
Taking down old existing MCB of any capacity carefully and depositing in store of respective AGE(E/M)
Supply only 1 Phase, 2 Wire, Dual Source, Pre-paid Energy Meters, with PLSI sensing, IS -15884 with Pre Payment capacitive touch Key pad, Bluetooth, based Digital having current range 10-60Amp, 240V, accuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC inbuilt feature to sense the DG mode through PLSI, dual source registration with respect to Grid as well as DG supply (wireless, without DCU, USB, pendrive & SIM card, complete all as specified and directed. Area wise quantities are as under:- (Subroto Park :- 8, 56 ASP, AF :- 4, MCC AF Station :- 2, 25 Wing Rajokri :- 5, AF Station Palam :- 15) Total :- 34 Nos
Supply only 3 Phase, 4 Wire, Dual Source, Pre-paid Energy Meters,with PLSI sensing, IS -15884 with Pre Payment capacitive touch Key pad, Bluetooth based Digital having current range 10-60Amp, 415V, accuracy class 1.0 along with Parallel home display split Unit, with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature to sense the DG mode through PLSI, dual source registration with respect to Grid as well as DG supply (wireless, without DCU, USB, pendrive & SIM card, complete all as specified and directed. Area wise quantities are as under:- (Subroto Park :- 2, 56 ASP, AF :- 1, MCC AF Station :- 1, 25 Wing Rajokri :- 1, AF Station Palam :- 4) Total :- 9 Nos
Supply and install high wall split heavy duty industrial units indoor/outdoor, capacity 2 Ton complete unit copper tube type with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with 3 star rating, fitted on wall and out door unit to be fixing on roof/wall including connections of AC, bolting , nuts , supporting stand clamping, 3 core copper cable, cooling tube, drain water pipe, etc all as specified and directed by Engineer -in -Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase with time delay relay with by pass button, naturally air cooled indoor type & designed for input variation between 170 V to 250 V (low voltage cut off below 170 volts and high voltage cut off at 250 Volts) with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA including and necessary electrical connections all as specified and directed by Engr-In-Charge.
M & L Design, development, supply commissioning & testing EHCC certified ground tubular effective Tripot type chemical earthing system ( CPRI tested for 15 KA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit of the standard size comprising of 25mm x 3mtr long copper rod as primary conductor and hollow pure Copper tube of dia 50mm x 3mtrs long as secondary conductor to install with suitable connection terminal coforming of IS 3043: 1987 specification, highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation 02 Bags / 60 Kgs minimum or sufficient quantities required as per site complete including FRP earthing pit clause suitable cover, material and labour including maximum 15 mtr copper erthing strip and testing after completipon and result should be less than one Ohm complete, all as specified and as directed by Engineer-in Charge.
AMIT ASSOCIATES
M/s Nand Kishore Anil Kumar
Leo Air and Power Solution pvt Ltd.
LUMOS INFRA PVT LTD
GANGA INFRABUILD PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .