Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.4 LAccepted-AOC | L-1 | Accepted-AOC BEING L1 | |
| 2 | L-2₹7.9 L+₹1.2 L (18.5%)Rejected-Finance R O KHOJA BAGH BARAMULLA JAMMU KASHMIR | BARAMULLA | BARAMULLA | JAMMU AND KASHMIR | 193103 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹7.9 L+₹1.3 L (19.5%)Rejected-Finance 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹8.2 L+₹1.6 L (23.9%)Rejected-Finance | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹10.5 L+₹3.8 L (57.2%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
30 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS c/o 56 APO
REPAIR MAINT OF SECURITY LIGHT FLOOD LIGHTS AND ALLIED WORKS AT KHREUH AND SHER E SHALI GRN UNDER GE 861 EWS
2023_MES_593419_1
GE 861 EWS-18/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
As per tender documents
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹24,000
Yes
21 Jul 2023
4 May 2023
6 Jun 2023
4 May 2023
30 May 2023
19 May 2023
Amount
Taking down old unsv security light/street lights and S&F 30 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure die-cast aluminium housing with highly efficient LEDs as lighting source and PC cover with integrated lens with IP66 protection and impact resistance of IK07 including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Havells Cat Part No VILUMINASL30WLED75PASYBOPC or equivalent from the makes provided in Appendix 'A' to particular specifications.
Taking down old unsv flood lights and S&F 50 Watt energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Havells Cat Part No JETAALBAFLOODLIGHT50W or equivalent from the makes provided in Appendix 'A' to particular specifications.
Taking down old unsv security light/street lights and S&F 60 Watt new generation energy saving and environmental friendly long life LED street light made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP66 protection and impact resistance of IK07 including necessary connection suitable size copper conductor cable, complete all as specified and as directed. Make Havells Cat Part No ENDURAPEARLNEOSL60WLED757PASYTOPCAST or equivalent from the makes provided in Appendix 'A' to particular specifications.
Dismantling insulators any type, any size, complete all as specified and directed.
Dismantling and taking out of ACSR or AAC conductors, complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m complete all as specified and directed.
1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers complete all as specified and directed. Note: Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
All as per item No. 7 here-in-before but cross sectional area 16 Sqmm 4.0 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in depth, complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point, complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified.
40mm dia GI tubing, 'light grade' with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
S&F in repair security light bracket with 1.20mtrs long galvanised iron pipe, 40mm dia, 'light grade' including flat iron clamps made of FI 40mmx5mm, nuts, bolts and washers including painting with two coats of synthetic enamel paint over one coat of red oxide primer, complete all as specified and directed.
Replacement of outdoor type SMC junction box of size 200x140x95mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with suitable fixing arrangement bus bar with single electrolytic aluminium for both phase and neutral supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and out let , provision for cable connection, MCB SP 6 Amps rating 'B' curve for controling the pole light including necessary connection, complete as specified and directed. Make Sintex Cat Part No GSJB2014 or equivalent from the makes provided in Appendix 'A' to particular specifications.
Replacement of cable PVC FR round sheathed, copper conductor cable of size 1.5 Sqmm 3 core drawn from juntion box to street light fitting, complete all as specified and directed.
Supply & fix in repair Rigid non-metallic grade PVC conduit of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed.
Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint, complete all as specified and directed.
Painting of steel tubular electrical poles cross arms channels etc after scrapping the old patchy cracked paint and applying one coat of aluminium paint to complete pole,clamps,channel ,cross arms and black strip of 30cm up to 1.5 mtr height on the same including preparation of surfaces complete all as specified and directed.
Painting of PCC poles with bracket/fitting etc complete by scrubbing old deteriorated paint and preparing the surfaces and applying two coats of cement base paint including colour strip of two coats of synthetic enamel paint upto 1.50 mtr height, writing pole No. in black base, complete all as specified.
S & F in repair bus bar chamber of size 60x60x45cm suitable for 3 phase 433 volts, outdoor type made out of 3.15mm thick MS sheet with 200 Amps rated aluminium bus bar(4 Nos) PVC sleeves and coloured (red, yellow, blue and black) with locking arrangements and angle iron stand of size 40x40x6mm frame grouted in ground with PCC foundation 1:2:4 type B-1 with 20mm graded stone aggregate alongwith all necessary cable connections, lugs and cable gland including 2 coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Trimming of trees branches from electric over head lines and clearing of 2 meter distance horizontal and vertical from outer edge of conductor including removing cut branches 50 Mtr (minimum) away from the place all as directed. Note: Contractor will ensure shut down on the feeder in writing before commencement of work on electrical lines.
Make bore beneath road/cement path/hard standing for GI pipe 40 to 50 mm, 'light grade' for passing armoured cable including making good the disturbed surface as per site requirement, complete all as specified and directed.
Supplying and fixing 1100volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core 6 Ssqmm cable flat or circular, complete all as specified and directed.
Replacement of electronic driver suitable for 25/30 watt LED security light, complete all as specified and directed.
Replacement of electronic driver suitable for 45/48/60 watt LED security light, complete all as specified and directed.
M/S HAMIDULLAH KHUROO
M/S TAHIRA ENTERPRISES
AYOOB CONSTRUCTION COMPANY
osho traders
M/S HAFIZ AND SONS
M/S A.N CONSTRUCTIONs
M/S Hilal Builders
M/S AK ENTERPRISES
SAMEER CONSTRUCTIONS
M/S STARE BUILDERS
M/S SHEIKH FEROOZ AHMAD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .