EXECUTIVE ENGINEER, ROAD DIVISION NO 1 MUZAFFARPUR
EE
ROAD DIVISION NO 1 MUZAFFARPUR
SUPERINTENDING ENGINEER, NORTH BIHAR ROAD CIRCLE MUZAFFARPUR
SE
LONG TERM OUTPUT AND PERFORMANCE BASED ROAD ASSETS MAINTENANCE CONTRACT OF ROADS, PACKAGE NO. - 04A/OPRMC-III UNDER ROAD DIVISION NO. - 1, MUZAFFARPUR
140960
Re-tender NIT No.- RCD/10/MUZ-1/2026-27
Open Tender
CIVIL
Muzaffarpur
• Registration
• Bid Security
(Bid Security can be paid through offline or online
mode)
• Cost of BOQ
• Bid Validity
• Conflict of Interest
• Bidder's Information Sheet
• Joint Venture Information Sheet
• Undertaking by the Joint Venture Partners
• Pending Litigation
• Historical Contract Non-Performance
• Net Profit
• Net Worth
• Annual Turnover
• Bid Capacity
• Financial Resources
• Existing Committements of on-going Works
• General Experience
• Specific Experience
• Personnel
• Equipment
• Initial Tentative Program of Performance
• Project Specific Information
• Power of Attorney of Signatory of Bid.
• Affidavit
CIVIL
ITEM RATE
L1
1
24 documents required · 24 mandatory
₹10,000
Processing Fee: 11800
₹1.9 Cr
Office of the Cheif Engineer, North, Road Construction Department, Bihar, Patna
30 Sept 2026
30 Sept 2026
9 Oct 2026
1 Oct 2026
9 Oct 2026
1 Oct 2026
5 Oct 2026
Any Contractor registered with the Central Government/ Any State Government or Any PSU or an agency of International or National repute may participate in the tender but registration with the Road Construction Department, Bihar will be essential after issuance of Letter of Acceptance and before execution of Agreement.
(a) through offline mode in the form of Bank Guarantee of Nationalized/ Scheduled Bank duly endorsed/ pledged to Executive Engineer, Road Division No-1,Muzaffarpur.
Through online mode only i.e. Internet Payment Gateway, Net Banking, NEFT/RTGS etc. Bids along with necessary online payment must be submitted through e-procurement portal https://eproc2.bihar.gov.in before the bid submission end date and the time specified.
Bids should be valid for not less than 180 days after bid submission end date or beyond any period of extension if requested. A Bid valid for a shorter period shall be rejected by the Employer as non-responsive.
No conflicts of interests in accordance with ITB Sub-Clause 4.3.
Copies of original documents defining the constitution or legal status, place of registration, and principal place of business; written power of attorney of the signatory of the bid to commit the Bidder.
Copies of original documents defining the constitution or legal status, place of registration, and principal place of business of the Joint Venture.
On Non-Judicial Stamp Paper of Appropriate Value.
Information regarding litigation.
Information regarding any litigation, arbitration or blacklisting, resulting from contracts executed by the Bidder in the last five years or currently under execution. The information shall include the names of the parties concerned, the disputed amount, cause of litigation, and matter in dispute.
Submission of audited balance sheets acceptable to the Employer, for the last five [5] years to demonstrate the current soundness of the bidders financial position and its prospective long term profitability. The Bidder should have made a Net Profit in any three [3] years in the last five [5] years.
The Bidder should have made a Net Worth not less than 10% of Estimated Cost Value (ECV) in latest financial years of last [5] five years.
Annual Turnover in any one [1] year in last five [5] year must not be less than 40% of the Estimated Cost Value (ECV) (calculated as total certified payments received for Contracts in progress or completed, within the last five [5] years). Note: 1. Financial turnover and cost of completed works of previous financial years shall be given a weighting of 8% per year to update the costs. 2. Year 1 will be the latest completed financial year, preceding the bidding. Year 2 shall be immediately preceding year 1 and so on. In case the Bid Submission date falls within 3 (three) months of the close of the latest financial year, the bidder shall ignore such financial year for the purpose of its bid and furnish all its information and certification with reference to the 5 (five) years preceding its latest financial year i.e. 2025-26. For the avoidance of doubt, financial year shall, for the purpose of the Bid hereunder, mean the accounting year followed by the Bidder in the course of its normal business.
Bidders who meet the minimum Qualifying Criteria stipulated in Clause 2.1 to 2.6 will be qualified, only if, their Available Bid Capacity is more than the Total Bid Value of the Works. The Available Bid Capacity shall be assessed/ calculated as under: Assessed Available Bid Capacity = A x N x 1 - B Where; A = Maximum Value of Civil Construction & Maintenance Works executed in any One [1] year during the last five [5] years updated to the price level of financial year [2026-27] by the Bidder taking into account of the completed as well as works in progress. N = Number of years prescribed for completion of the works for which bids are invited. B = Value updated at the price level of financial year [2026-27] of existing commitments and on-going works to be completed by the bidder during the next 84 months or Sum of the values updated at the price level of financial year of [2026-27] the existing commitments and ongoing works to be completed by each of the JV partner during the next 84 months. However; where the bidders are bidding for more than one [1] Contract Packages, the Value of its other allotted works will be included in the value of ‘B’ and the Employer may write a letter to the bidder to submit self-declaration regarding allotment of new works other than the works declared in the bid. The bidder shall be obliged to submit the above details within the stipulated time and before the date of evaluation of technical bid. Any non-compliance in this regard by the bidder shall be treated as bid non-responsive and shall be liable for rejection of bid. The Bidder is to complete form of Current Contract Commitments as part of their Bid for the determination of this value and Current Contract Commitments must be duly certified by the Engineer-in-charge.
The Bidder must demonstrate access to, or availability of, financial resources such as liquid assets, unencumbered real assets, lines of credit, and other financial means, other than any contractual advance payments to meet: Credit Lines/ Letter of Credit / Solvency Certificates from Banks etc. shall be not less than 10% of the total Estimated Cost Value.
As Per S. No. 14
Experience under Road Maintenance or Improvement Contract or Construction Contract as Contractor/ Sub-Contractor, SBD, CMBD, HAM, EPC, BOT, BOOT (Developers/ Operators) or Civil Works/Management Contractor for at least the last five [5] years prior to the applications submission deadline.
(a) Participation as Contractor, Management Contractor, or Sub-Contractor or BOT, BOOT Developer/Operator with in the last five [5] years, in Road Construction or Maintenance Works Contracts, of which upto two [2] Contracts have a Combined Values not less than 50% of Estimated Cost Value (ECV) and have been successfully completed/ substantially completed. The Works completed must be in similar nature to the Works & Services of the proposed Contract. For the purpose of the above requirement: (i) OPRMC Contracts shall be considered as substantially completed if the Contractor has completed 100% of Minor Improvement Works feasible, 100% of Initial Rectification Works feasible and 100% of Periodic Maintenance Works feasible. (ii) all other types of Contracts shall be considered as substantially completed if the Contractor has completed 90% of the Value of Works.
The Bidder must demonstrate that it has the personnel for the key positions that meet the following requirements. The Bidder should provide the details of the proposed personnel and their experience record using the Forms PER-1 and PER-2 of Section 4, Bidding Forms supported by the experience certificates duly countersigned by the respective clients.
The Bidder shall own at least One Hot Mix Plant (40-60 tonne/hour Capacity) not more than 15 years age. The Bidder must demonstrate & submit the supportive documents that it has or has access to (own/lease/hire etc. and to be procured) the key equipment (machinery) listed as under:
To demonstrate a clear understanding of the requirements of the Contract, Bidders shall provide the following: (i) a bar chart sub-divided into sections for each road showing the major activities to be carried out for Ordinary Maintenance Works, Initial Rectification Works, Periodic Maintenance Works and Minor Improvement Works (separately for Improvement & Strengthening). (ii) activities shall be shown against time, with linkages shown between related/ sequential activities as far as possible and appropriate; (iii) a bar chart or schedule showing the usage of major plant, including those listed in Contractor’s Equipment. Duly supported with equipment planning and deployment, showing with broad calculations justifying the bidder’s capability for the execution and completion of the work as per the technical specifications and within the periods of completion as per the stipulated milestones.
The Bidder shall provide the statements in respect to the following information: (a) Proposed methodology for undertaking Ordinary Maintenance (OM), Initial Rectification (IR), Periodic Maintenance including re-application of Road Marking (PM) and Minor Improvement including Strengthening (MI), and identification of road sections that major activities shall be applied. (b) Details of safety, traffic, environmental management aspects to be adopted by the Bidder. “As per the Checklist provided in Form OM-14 of Technical Specifications.” (c) Bidder’s experience in managing testing of work. (d) Statement indicating whether: i the Bidder accepts the Sample Quality Plan and if so, that the Bidder will provide an updated Quality Plan within the time frame stated in Clause 14.1 of Section 5A, if awarded the Contract; or ii the Bidder does not accept the Sample Quality Plan, in which case the Bidder will be required to provide its own Quality Plan in accordance with and within the time frame stated in 14.1 of Section 5A, and which as a minimum, includes the same level of detail as the Sample Quality Plan and explains the purpose, application, responsibilities and requirements to undertake works in accordance with the intent of the Contract, the general provisions for the occupational health and safety of employees and the public, environmental management requirements and the Statutory Laws of India Statement in respect to the Quality Plan. (e) All Bidders shall provide with their Bid a preliminary description of the proposed work method and program and resource schedules, including drawings and charts, as necessary.
As Per NIT
(a) Bidders will have to declare by affidavit that they have not been declared defaulter/rescinded/debarred/blacklisted by the State Govt./Central Govt./Public Undertaking. If such affidavit is subsequently found to be false, their tender shall not be considered and further legal action shall be initiated.
Works Under Package No.-04A/OPRMC-III/Muzaffarpur -1
84 Months
As per NIT
Quantity
84 months
Description of Item
In fig.
Repairs to bituminous carriage way wherever required to bring the specified service level for the damages pot holes, rut, cracks & depressions, delaminating, stripping, edge breaking, dig out etc. and any additional activity necessary to achieve the service level objective.
Removal of jungle on both sides of the road to bring the service level by uprooting and burn to ashes (Clause 201)- Clearing & Grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness, except forestation work done by other Government agencies.
Description of Item
In fig.
Providing Periodic Maintenance to Single and Intermediate Lanes including profile correction with the following items of works to obtain the required service level.
Description of Item
In fig.
Providing Re-Application of Continuous edge line marking (Providing and laying of Hot applied Thermoplastic Compound 2.5mm thick including reflectorising glass beads @250gms per sqm area ,thickness of 2.5mm is exclusive of surface applied glass beads as per IRC:35 the finished surface to be level ,uniform and free from streaks and holes .) at interval of minimum 2 years of previous application (including the road marking carried out under the Periodic Maintenance Works) in Single & Intermediate Lanes including auxiliary items as per the MORTH/ IRC latest Specifications & as per direction of Engineer-in-charge.
SOR No.
In fig.
Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stackingserviceable and unserviceable materials separately /By Mechanical means/Bituminous course
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.Ordinary Soil By mechanical means(Depth upto 3mtrs)
Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2.
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401./Rate per cum for grading -II Material
Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom.
Providing and laying 25 mm thick mastic asphalt wearing course with paving grade bitumen meeting the requirements given in table 500-39, prepared by using mastic cooker and laid to required level and slope after cleaning the surface, including providing antiskid surface with bitumen precoated fine grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005 cum per 10sqm and at an approximate spacing of 10cm center to center in both directions, pressed into surface when the temperature of surfaces is not less than 1000c, protruding 1mm to 4mm over mastic surface, all complete as per clause 516.
Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.
Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383 as per actual Design Mix, possessing 28 days minimum compressive strength of 40 (Forty) Mpa and 28 days minimum flexural strength of 4.5 (Four point five) MPa, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing
Painting on Wood Surfaces (Providing and applying two coats of ready mix paint of approved brand on wood surface after thorough cleaning of surface to give an even shade)
Painting on Steel Surfaces (Providing and applying two coats of ready mix paint of approved brand on steel surface after through cleaning of surface to give an even shade)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.)
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)/5th kilometer Stone (pre cast)
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)/ Ordinary KM Stone
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc)/Hectometre stone
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.The retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Goverment Laboratory/Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad.Alternatively, a certificate conforming to ASTM specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation, the Employer/Client, if so desires could seek for a performance guarantee which would released after receipt a certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & proof of the same report shall be uploaded while quoting tendor. The retro reflective sheeting shall be covered under 7 years warranty to be provided from the original sheeting manufacturer, as per Clause 6.9 of IRC 67:2012. At the end of 7 years, the sheeting shall retain atleast 80% of its original retro-reflectance. When totally wet, the sheeting shall show not less than 90% of the value of the desired retro reflectance./90cmEquileteral Triangle
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.The retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Goverment Laboratory/Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad.Alternatively, a certificate conforming to ASTM specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation, the Employer/Client, if so desires could seek for a performance guarantee which would released after receipt a certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & proof of the same report shall be uploaded while quoting tendor. The retro reflective sheeting shall be covered under 7 years warranty to be provided from the original sheeting manufacturer, as per Clause 6.9 of IRC 67:2012. At the end of 7 years, the sheeting shall retain atleast 80% of its original retro-reflectance. When totally wet, the sheeting shall show not less than 90% of the value of the desired retro reflectance./80cmx60cm Rectangular
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.The retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Goverment Laboratory/Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad.Alternatively, a certificate conforming to ASTM specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation, the Employer/Client, if so desires could seek for a performance guarantee which would released after receipt a certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & proof of the same report shall be uploaded while quoting tendor. The retro reflective sheeting shall be covered under 7 years warranty to be provided from the original sheeting manufacturer, as per Clause 6.9 of IRC 67:2012. At the end of 7 years, the sheeting shall retain atleast 80% of its original retro-reflectance. When totally wet, the sheeting shall show not less than 90% of the value of the desired retro reflectance./60cmx45cm Rectangular
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.The retro reflective sheeting shall be tested for a certificate of having the sheeting tested for coefficient of retro reflection, daytime colour and luminance, shrinkage, flexibility, linear removal, adhesion, impact resistance, specular gloss and fungus resistance, 3 years outdoor weathering and its having passed these tests shall be obtained from International/Goverment Laboratory/Institute by the manufacturer of the sheeting and in case the certificate is obtained from international condition, it should also be obtained from indian condition within 3 years of launching of product by the manufacture in abroad.Alternatively, a certificate conforming to ASTM specification (D4956-09) on artificial accelerated weathering requirements from a reputed laboratory in India can be accepted provisionally.In such a situation, the Employer/Client, if so desires could seek for a performance guarantee which would released after receipt a certificate meeting the requirement of three years outdoor weathering of the sheeting as per IRC 67:2012 & proof of the same report shall be uploaded while quoting tendor. The retro reflective sheeting shall be covered under 7 years warranty to be provided from the original sheeting manufacturer, as per Clause 6.9 of IRC 67:2012. At the end of 7 years, the sheeting shall retain atleast 80% of its original retro-reflectance. When totally wet, the sheeting shall show not less than 90% of the value of the desired retro reflectance./90cm High octagonal
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces)
Reflective Raised Pavement Marker with Shank (Cat Eye/Road Stud) Supplying and fixing of raised pavement marker with made of aluminium alloy or plastic body moulded from ASA (Acrylic Styrene Acrylonitrite) or HIPS (High Impact Polystyrene) or Acrylonitrite Butadiene Styrene (ABS) or any other suitable material approved by the Engineer. The marker shall support a load of 13,635 kg tested in accordance with ASTM D4280. The reflective panels shall consist of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lens face.Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 of equivalent.The slop or retro-reflecting surface shall preferably be 35+/-5 degree to base and the area of each retro- reflecting surface shall not be less than 13.00 sq.cm the marker height shall not be less than 10 mm and shall not exceed 20 mm & width shall not exceed 130 mm. The base of the marker shall be flat within 1.3 mm, all road studs shall be legibly marked with the name,trade or other means of identification of the manufacturer, epoxy installations, excess adhesive around the edge of the marker, excess adhesive on the pavement and adhesive on the exposed surface of the markers shall be immediately removed. The contractor shall submit a two year warranty for satisfactory field performance including stipilated retro-reflectance of the reflecting panel, to the Engineer.In addition, a two year warranty for satifactory infield performance of the finished road marker shall also given by the contractor who carrier out the work of fixing of reflective road marker. In Case the markers are displaced, damaged, get worn out or lose their reflectivity compared to stipulated standards, the contractor would be required to replace all such markers within 15 days of the intimation from the Engineer, at his own cost.
Laying Reinforced cement concrete pipe NP4 / prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . /1000mm Dia
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications.
Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications/Sandy material
Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications.
Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification.
Earth work in excavation of foundation of structures as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material./Mechanical Means (Depth upto 3mtrs)
Plain/Reinforced Cement concrete in open Foundation complete as per Drawing and Technical specifications.PCC Grade M15 using batching plant & manual placing
Plain/Reinforced Cement concrete in open Foundation complete as per Drawing and Technical specifications. PCC Grade M20 using batching plant,transit mixer & manual placing
Plain/Reinforced cement concrete for wall & slab etc. complete as per Drawing and Technical specifications.RCC Grade M20 using batching plant, transit mixer & concrete pump
Supplying, fitting and placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical specifications
Providing weep holes in Brick masonary/ plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20H towards drawing face. Complete as per drawing and Technical specifications.
Reinforced cement concrete approach slab including reinforcement and formwork complete as per Drawing and Technical specifications.
Drainage spouts complete as per Drawing and Technical Specifications.
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical specifications.
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specifications./Sandy soil
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification.
Providing and laying pitching on slopes Laid over prepared filter media including boulder apron laid dry in front of toe as per drawing and technical specifications./Stone Boulder
Providing and laying Flooring complete as per drawing and Technical specifications laid over cement concrete bedding./Rubble stone laid in cement mortar 1:3
Works Under Package No.-04A/OPRMC-III/Muzaffarpur-1
84 Months
As per NIT
Quantity
84 months
Description of Item
In fig.
Repairs to bituminous carriage way wherever required to bring the specified service level for the damages pot holes, rut, cracks & depressions, delaminating, stripping, edge breaking, dig out etc. and any additional activity necessary to achieve the service level objective.
Removal of jungle on both sides of the road to bring the service level by uprooting and burn to ashes (Clause 201)- Clearing & Grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness, except forestation work done by other Government agencies.
Description of Item
In fig.
Providing Periodic Maintenance to Single and Intermediate Lanes including profile correction with the following items of works to obtain the required service level.
Description of Item
In fig.
Providing Re-Application of Thermoplastic Edge Line Marking at interval of minimum 2 years of previous application (including the road marking carried out under the Periodic Maintenance Works) in Single & Intermediate Lanes including auxiliary items as per the MORTH/ IRC latest Specifications & as per direction of Engineer-in-charge.
SOR No.
In fig.
Dismantling of Flexible Pavements (bituminous)
Earthwork in excavation of foundation of structure
Construction of Embankment with Material Obtained from Borrow Pits
Construction of granular sub-base grade ii
Providing and applying tack coat on Bituminous
Providing and laying 25 mm thick mastic asphalt
DLC Dry lean cement concrete Sub- base
CCP(PQC) Construction of un-reinforced, dowel jointed, plain cement concrete pavement
Painting on Wood Surfaces
Painting on Steel Surfaces
Road Marking
Kilometre Stone 5 th KM Stone
Kilometre Stone Ordinary KM Stone
Kilometre Stone Hectometre stone
P/F retro-reflective sign board as per IRC 67 60cm Circular
P/F retro-reflective sign board as per IRC 67 80cmX 60cm
P/F retro-reflective sign board as per IRC 67 60cmX 45cm
P/F retro-reflective sign board as per IRC 67 90 cm Octagon
Painting Two Coats on New Concrete Surfaces
Road Studs
Providing and Laying reinforced cement concrete pipe NP4
Providing Weep holes
Back filling
RCC Railing
P/F Filter Joint
Earth work in excavation of foundation of structures
Plain/Reinforced Cement Concrete in Open Foundation complete -PCC Grade M15
Plain/Reinforced Cement Concrete in Open Foundation complete -PCC Grade M15
Plain/Reinforced cement concrete in sub-structure complete- PCC Grade M20
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete
Providing weep holes
Reinforced cement concrete approach slab including reinforcement and formwork complete
Drainage Spouts complete
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete
Painting on Kerb
Back filling
Under neath Pitching
Providing and laying boulders apron
Providing and laying Flooring CM(1:3)
Providing and laying Flooring complete
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Re-tender NIT NO. -RCD_10MUZ-1.pdf
NIT • 2.10 MB
Approved MBD 4A 30.09.2026.pdf
NIT • 4.36 MB
Corrigendum (1).pdf
NIT • 0.33 MB
_Technical Template OPRMC-III 4A 30.09.2026.xlsx
NIT • 0.02 MB
Financial Template_04A 30.09.2026.xlsx
NIT • 0.05 MB
E- proc 2.0 form fee and tender.pdf
NIT • 1.83 MB
Letter No-3103(S) Dt 06.05.2026 (2).pdf
NIT • 1.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .