Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹34.4 L+₹6.2 L (21.9%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹36.0 L+₹7.8 L (27.6%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹36.7 L+₹8.5 L (30.0%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹37.7 L+₹9.5 L (33.6%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹42.7 L
EMD Value
₹85,500
Closing Date
22 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF Lohegoan
GE AF Lohegoan Pune Pin 411032
ADDN/ALTN/RENOVATION OF ASSEMBLY GROUND AND BASKET BALL COURT AND ALLIED SERVICES IN KV-I AT AF PUNE UNDER GE AF LOHEGAON
2023_MES_590623_1
8677
Open Tender
Civil Works
Item Rate
180 days
GE AF Lohegoan
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE AF lohegoan
₹85,500
Yes
25 Jul 2023
22 Apr 2023
29 May 2023
22 Apr 2023
22 May 2023
9 May 2023
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Hard/ Dense soil complete all as specified and as directed by Engr-in-Charge.
Roughening surface of old concrete floor/wall by packing , sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in Hard/ Dense soil complete all as specified and directed
M&L for 75mm thick PCC type D2(1:4:8) using 40mm graded crushed aggregate as in sub base, finished even and fair complete all as specified and as directed by Engr-in-Charge.
M&L for PCC type B0 (1:2:4) using 12.5 mm graded crushed aggregate in coping ,mass concrete.complete all as specified and as directed by Engr-in-Charge.
M&l for PCC type D2(1:4:8) using 40mm graded crushed aggregate as mass conc and filling of foundation complete all as specified and directed
M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:6 complete all as specified and directed
M&L for 15mm thick rendering on fair faces of brick works finished even and smooth without using extra cement in cement mortar 1: 4 complete all as specified and as directed
M&L for preparing of new surface of brick work, concrete plastered or unplastered surface and applying two coat of Acrylic smooth exterior paint of required shade , over a coat of primer complete all as specified and directed.
Preperation of old steel surface of any description over 10cm in width or girth ,not otherwise described and applying two coat of synthetic enamal paint complete all as specified and directed
M&L for precast cement concrete Type B1, 1:2:4 (20mm graded aggregate) in lindings, cover slabs (for manholes etc), chullah hoods, chhajja, water troughs, shelves and similar articles with plain faces, setting in CM 1:4, complete all as specified and as directed
M&L mild steel TMT bars10mm dia and over, cut length, bent to shape required , including cranking , bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to TMT complete all as specified and directed
M&L for Moorum / red bajri filling in floors(300 mm average thickness) or pavings ,laid in layers n exc 15 cm thick spread levelled and rammed including watering and consolidation complete all as specified and as directed by Engr-in-Charge..
M & L Hardcore with broken stone of gauge exc 63mm but n exc 100mm, deposited, spread and levelled and layer n.exc 15cm thick, water and rolled/rammed to a true surface complete all as specified and directed
M&L for Rolling and consolidating formation surfaces in cutting rolling with power roller of 8 to 12 tonne complete all as specified and directed
M&L for 100mm thick PCC type D2(1:4:8) using 40mm graded crushed aggregate as in sub base, finished even and fair complete all as specified and directed
M &L for Form work to edges of concrete flats nexc 20 cm wide complete all as specified and directed
M&L for cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement percubic metre, thickness of concrete 25 cm or less complete all as specified and directed
Supply only metalic floor harderner (300gm/Sqm) complete all as specified and directed
M & L for preperation of Concrete Joints with minimum width of joints 10 mm but n exc. 15 mm wide and minimum depth of joints15 mm but n exc. 25 mm on slabs of pavements ,cleaning the surfaces by means of air compressor or vaccum cleaner and M&L for joint filling with polyurethene sealent conforming to BS - 5212 (type FB) after applying primer and masking tape on front edge of joints to prevent accidental spillage of sealent on top surfaces and to give a neat finish to the sealent, including required back up rod and removing masking tape after sealent has been applied all as specified and as directed at site, all as directed.Note: Rate included for necessory Backup Rods , Minimum depth of sealent should not be less than 15 mm
Material & Labour for Eight Layer Synthetic Acrylic flooring for Basket Ball Court including Acrylic concrete Primer(Ist Layer), Acrylic Resurfacer (2nd Layer) , Triple Layer of Acrylic Rubber Cushion (3rd,4th & 5th Layer), Base Colour Coat with Dana Paint (6th layer), Hybride waterborne PU Top coat (7th & 8th Layer) and two coat of over all Line marking, complete all as specified and directed by Engr-in-Charge and as per manufacturer’s instruction.
Material & Labour for 25 mm thick Reinforced Fibre Board Basket ball board with Basket including all necessary fittings, etc as per standared specifications and as directed by Engr-in- Charge.
M&L sand filling (25 mm average thickness) under floors in foundations and for laying Interlocking paver blocks including watering and consolidation complete all as specified and as directed by Engr-in-Charge..
M&L machine pressed precast concrete Glossy finish interlocking paver block any shape and size polished with white cement and pigment confirming to IS 15658-2006 of 60 mm thickiness M-35 grade complete all as specified and as directed by Engr-in-Charge.
M&L for PCC type B0 (1:2:4) using 12.5 mm graded crushed aggregate in coping ,mass concrete complete all as specified and directed
Returning, Filling in, including spreading levlling ,watering and well ramming in layers nexc 25cm thick complete in Hard/ Dense soil complete all as specified and as directed by Engr-in-Charge..
Removing excavated material n, exe 50m and depositing where directedat a level n, exe 1.5 m above the starting poit complete all as specified and as directed by Engr-in-Charge..
purva engineears and contracters
Parmanand Enterprises
godavari construction
santulan & Company
S.R.M.K Enterprises
M/S SANDEEP CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .