Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.1 LAccepted-AOC | L-1 | Accepted-AOC Lowest bidder | |
| 2 | L-2₹30.8 L+₹82,108.60 (2.74%)Rejected-AOC | L-2 | Rejected-AOC other than lowest bidder | |
| 3 | L-3₹31.4 L+₹1.4 L (4.79%)Rejected-AOC | L-3 | Rejected-AOC other than lowest bidder | |
| 4 | L-4₹32.6 L+₹2.7 L (9.02%)Rejected-AOC QTR NO 7 REHARI COLONY JAMMU TAWI J K PIN 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L-4 | Rejected-AOC other than lowest bidder | |
| 5 | L-5₹33.5 L+₹3.6 L (12.0%)Rejected-AOC | L-5 | Rejected-AOC other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
4 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Ram G
GE Kaluchak Pin-900673 C/O 56 APO
REHABILITATION OF TEMP BLDGS INCLUDING GALVALUME SHEETS, FALSE CEILINGS, IMPROVEMENT OF SECURITY WALL, REPAIR TO SECURITY WALL PERIMETER FENCING, PATHWAY AND OTHER MISC WORKS AT KALUCHAK MIL STN UNDER GE KALUCHAK
2023_MES_573695_1
GE/KC/NIT-68/2022-23
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹72,000
Yes
25 Mar 2023
7 Jan 2023
11 Feb 2023
7 Jan 2023
4 Feb 2023
21 Jan 2023
7 Jan 2023 - 14 Jan 2023
Amount
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering, complete all as specified & directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position (framed work), complete all as specified & directed.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 01 here-in-before, complete all as specified & directed.
15mm thick rendering in cement mortar 1:6 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS:1161-1979 grade St.-240, complete all as specified & directed.
Mild steel framed work as in plates (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-290 grade-E-165, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
6mm thick asbestos cement, corrugated or semi-corrugated sheeting in roof, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
All as per Srl item No.16 above but except sheets
Asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets 6mm thick fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
Mild steel framed work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, complete all as specified & directed.
Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame work for false ceiling, grid size 605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 3mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified and directed. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
Machine cut kota stone slab flooring, 18-20 mm thick of size not less than 55cmx55cm as per sample kept in GEs office, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing laid over and including 20mm screed layer in cement mortar 1:4, complete all as specified & directed.
Machine cut kota stone slab, 18-20 mm thick as per sample kept in GEs office as in vertical surfaces such as skirting/dado etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing, grinding and polishing, laid over and including 10mm thick screed bed in cement mortar 1:4, complete all as specified & directed.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as floor, finished even and fair to receive floor finishes, complete all as specified & directed.
50mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick joints with bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads, n exc 1.5 sqm, complete all as specified & directed.
3mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples etc, fixed in repairs, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of chalk whitening, complete all as specified.
Preparation of new plastered or concrete surfaces of walls and applying two coats of cement base paint over a coat of cement primer, complete all as specified & directed.
Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
60mm thick factory made chamfered edge cement concrete paver block of M-35 grade confirming to IS-15658-2006 of approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified & directed.
75mm thick PCC 1:3:6 (nominal mix), type C-2 using 40mm graded crushed stone aggregate as in sub base of floor etc, complete all as specified & directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
Excavation over areas not exc. 1.5m deep in any type of soil and getting out, complete all as specified & directed.
Excavation over areas exc. 1.5m but n exc 3.0mdeep in any type of soil and getting out, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan in any type of soil and getting out, complete all as specified & directed.
Excavation in trenches n exc. 1.5m wide and exc 1.5m deep but not exc. 3.0m deep in any type of soil and getting out, complete all as specified & directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
PCC 1:3:6 nominal mix, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
Use & waste of form work to sides of concrete foundation, footings, bases of columns, rafts and raft beamsand similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for rough finished surfaces of concrete, complete all as specified & directed.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work, not exceeding 200mm thick (horizontal or sloping) for rough finished surfaces of concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footing; including attached pilasters and buttresses, complete all as specified & directed.
RCC M-25, design mix, using 20mm graded crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified & directed.
TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
Precast cement concrete 1:2:4 (nominal mix), type B-1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4, complete all as specified & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces using liquid water proofing admixture as per manufacturer’s instructions, surface finished even and smooth without using extra cement, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid seperately.
Supply only liquid water proofing admixture, complete all as specifed & directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc., complete all as specified & directed.
75mm thick PCC 1:2:4, nominal mix, type B1, using 20mm graded crushed stone aggregate as in pavement, hard standing, path etc, surface finished even and fair, laid in alternate bays including form work, complete all as specified & directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 110mm bore, fixed in repairs, complete all as specified and directed.
PVC (SWR) vent cowl of size 110mm bore, fixed in repairs, complete all as specified & directed.
PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, 160mm bore, fixed in repairs, complete all as specified and directed.
PVC (SWR) junction single (Single T) equal or unequal, 160mm bore with oval access door, fixed in repairs, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 150mm, complete all as specified & directed.
Concrete bed to 200mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret 1:4:8 (Nominal mix) type D-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Reinforced concrete pipes, class NP3, laid & jointed complete with collars, bore of pipe 200mm, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified & directed.
Brickwork with sub-class ‘B’ bricks (old size), one brick thick honey comb walling built in cement mortar 1:4, complete all as specified & directed.
Supply only broken brick bats aggregate of 63mm nominal size, complete all as specified & directed.
M/S SUBASH CHANDER AND SONS
M/S SUDAGAR MAL
Hare krishna engineering const.
JK BUILDERS AND DEVELOPERS
M/S RAVINDER SINGH
Kanwal Nain Behl
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .