Loading…
Loading…
| # | Company | Rank | Status |
|---|---|---|---|
| 1 | 1Accepted-AOC | 1 | Accepted-AOC close tender |
| 2 | 1Accepted-AOC | 1 | Accepted-AOC close tender |
| 3 | 1Accepted-AOC SHOP NO 6 S K SHOOPIND COMPLEX JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | 1 | Accepted-AOC close tender |
| 4 | 1Accepted-AOC KUSHWAHA PATHOLOGY 4 TULSIDAS MARG LUCKNOW LUCKNOW LUCKNOW UTTAR PRADESH 226003 | LUCKNOW | UTTAR PRADESH | 226003 | 1 | Accepted-AOC close tender |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Feb 2020, 5:30 pmClosed
Joint Director and Superintendent Medical College
Joint Director and Superintendent Medical College Hospital Jabalpur Madhya Pradesh
Arthoscopy Products Ortho Implants
2020_DME_77955_1
5570
Open Tender
Miscellaneous Goods
Item Wise
5 days
Joint Director and Superintendent Medical College
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Payable To
₹50,000
19 May 2023
1 Feb 2020
2 Mar 2020
1 Feb 2020
28 Feb 2020
1 Feb 2020
Ortho Arthoscopy Products Implants
Interference screw all size
Interference Bio screw all size
Fixed Loop Endobutton all size
Adjustable Loop button
Suture Disc & Merelence tape
Meniscal Repair Implant all inside techniuqe - (all inside meniscal repair system with pre knotted 2 peek implants mounted on a straight rigid needle and can be deployed in the meniscus at any angle. It should gave an inbuilt depth penetration limiter to prevent the posterior capsule
Meniscal Repair Imnplant all inside technique (all inside meniscal repair system with pre knotted 2 peek implants mounted on a Curved rigid needle and can be deployed in the meniscus at any angle. It should gave an inbuilt depth penetration limiter to prevent the posterior capsule
Meniscal Repair implant all inside technique (all inside meniscal repair system with pre knotted 2 peek implants mounted on a reverse Curved rigid needle and can be deployed in the meniscus at any angle. It should grave and inbuilt depth penetration limiter to prevent posterior capsule
Knot pusher / cutter for the left behind suture in the all inside meniscal repair system
Suture Anchors for Bankart Repair (2.8mm Titanium Screw in anchors with high & low threads design, preloaded with single ultrahigh molecular weight Polythylene braided fiber for bankart / slap repair
Suture Anchors for Bankart Repair (3.5mm Titanium Screw in anchors with high & low threads design, preloaded with single ultrahigh molecular wiehgt Polythylene braided fiber for bankart / slap repair
Suture Anchors for Bankart Repair - 2.3 mm peek tap in anchors, preloaded with single ultrahigh molecular weight polythylne
Suture Anchors for Bankart Repair - 2.3 mm Biobsorbable (75% PLLA & 25% HA) tap in anchors, preloaded with single ultrahigh molecular weight polythylene braided fiber for bankart / slap repair
Suture Anchors for Bankart Repair - 2.9mm Biobsorbable (75% PLLA & 25% HA) tap in anchors, preloaded with single ultrahigh molecular weight polyethylene braided fiber for bankart / slap repair
Suture Anchors for Bankar Repair - 1.7mm all sture tap in anchor made up of high molecular weight polythylene braided fibre & preloaded with single ultrahigh molecular weight polythylene braided sutures which opens up to 3mm post deployment with special deployment mechanism through unique visual tactile & auditory cues indended for instability repair.
Sutre Anchors for Bankart Repair - 1.9mm all suture tap in anchor made up of high molecular wiehgt polyethylene braided fibre & preloaded with single ultrahigh molecular weight polyethylene braided sutures which opens up to 3mm post deployment with special deployment mechanism through unique visual tactile & auditory cues intended to instabilty repair
Suture Anchor for Rotator cuff repair (5.0mm Titanium screw in anchors with high & low threads design, preloaded with double ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair.
Suture Anchor for Rotator cuff repair (6.5mm Titanium screw in anchors with high & low threads design, preloaded with double ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (4.5mm peek tap in preloaded at distal end of the anchor with double ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (5.5mm peek tap in preloaded at distal end of the anchor with double ultrahigh molecular weight polyethylene braided fiber for rotaor cuff repair)
Suture Anchor for Rotator cuff repair (4.5mm Bioabsorbable (75% PLLA & 25% HA) Tap in anchors, preloaded at distal end of the anchor with double ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (5.5mm Bioaborbable (75% PLLA & 25% HA) Tap in anchors, prelaoded at distal end of the anchor with double ultrahigh molecular weight polyethylene braide fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (6.5mm Bioabsorable (75% PLLA & 25% HA) Tap in anchors, preloaded at distal end of the anchor with double ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (5.5mm Bioabsorbable (75% PLLA & 25% HA) Tap in anchors, preloaded at distal end at the anchor with Triple ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (4.5mm peek screw in anchors, preloaded with double ultrahigh molecular weight polythylene braided fiber with unique open architectural design allows for bone to interdigitate within the anchor thread profile and achieve excellent fixation secuirty available in double loaded ultraihigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair (4.0mm peek screw in anchors, preloaded with double ultrahigh molecular weight polythylene braided fiber with unique open architectural design allows for bone to interdigitate within the anchor thread profile and achieve excellent fixation security available double & Triple loaded ultrahigh molecular weight polyethylene braided fiber for rotator cuff repair
Suture Anchor for Rotator cuff repair ( 5.55mm tap in peek knorless lateral row anchor with offset barbed geometry threads & inner plug design to provide more precise fixationa nd suture tensioning of final repair
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .