Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Ok | |
| 2 | L2₹39.8 L+₹2.5 L (6.78%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹42.6 L+₹5.4 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹42.8 L+₹5.6 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹49.6 L+₹12.4 L (33.3%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
16 May 2020, 6:00 pmClosed
GE E/M BASE HOSP DELHI CANTT
GE E/M BASE HOSP DELHI CANTT
REPAIR/ REPLACEMENT OF COMPREHENSIVE MAINT OF UNSV ACBS, VCBS, PUMPS, GOD, DO, AND TRANSFORMER ALONG WITH CONNECTED LT/HT INFRASTRCTURE AND CONNECTED MISC E/M WORK UNDER GE EM BASE HOSPITAL DELHI CANTT-10
2020_MES_339177_1
GE/BH-06/2020-21
Open Tender
Electrical and Maintenance Works
Works
180 days
GE E/M BASE HOSP DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE E/M BASE HOSP DELHI CANTT
₹99,900
Yes
25 Jul 2020
16 Apr 2020
19 May 2020
16 Apr 2020
16 May 2020
30 Apr 2020
Amount
M&L for disconnecting power supply from HT OCB of capacity 11 KVA for repair works, complete servicing of the same through decarbonising, cleaning the isolating contacts, lubricating moving part, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, checking proper operation of trolley all as directed and testing, and putting on load complete all as specified and directed.
Disconnecting LT supply and servicing of Air circuit breaker of capacity 630 to 1500 Amps and rating 1100 V by cleaning and de-carbonising the contacts point cleaning with CRC checking proper operating of moving parts repair to charge spring mechanism checking of AC supply, parts tightening all nuts and bolts of components, lubricating moving parts with petroleum jelly as directed including testing and keeping in on load complete all as specified and directed.
Supplying, installation, commissioning and testing in replacement 11 KV Current Transformer (CT`s), indoor type, epoxy cast resin having ratio 30/15/5-5 Amps, core -1, Class 5 P10, 15 VA for protection , Core 2 Class 0.5 , 15 VA for metering, Short circuit time rating 13.4 kA for 3 Sec including associated wiring complete all as specified and directed.
S&F in replacement support rod with screws suitable for 630/800/1250 Amps, 11 KV HT VCB complete all as specified and directed.
S&F in replacement support insulator suitable for 630/800/1250 Amps, 11 KV HT VCB complete all as specified and directed.
S&F in replacement upper connector suitable for 630/800/1250 Amps, 11 KV HT VCB complete all as specified and directed.
S&F in replacement lower connector suitable for 630/800/1250 Amps, 11 KV HT VCB complete all as specified and directed.
Supply and installation in replacement Anti-condensation space-heater with Thermostatic control in cable and circuit breaker compartments of HT switchgears complete all as specified and directed.
Supplying, installation, commissioning and testing in replacement PT unit three phase, three limbs, up to 11 KV draw-out type, resin cast dry type, single ratio having primary voltage 11 KV & secondary voltage 110 volts, 50 VA class-1 including necessary bus bar connections & wiring for metering complete all as specified and directed.
S&F in replacement charging motor for 11 KV VCB of Make CG complete all as specified and directed.
S&F in replacement air breather complete with silica gel suitable for out door type step down power transformer up to 200 KVA to 1000 KVA as per existing make and model complete all as specified and directed.
M&L filtration & de-hydration of Transformer oil & alike for various equipment installed at BHDC through filtration machine to achieve required di-electric strength 50 kVA complete all as specified and directed. Note:- (a) Rate quoted for above item shall deemed to be inclusive of charges for testing of oil before filtration and after filtration of transformer, OCB & other equipment. (b) Result before filtration & after filtration of oil (Test Certificate) shall be submitted by the contractor to Engr-in- Charge.
Supply & topping up of transformer oil up to required level for transformer / OCBs / PT's / stabilizers / HT switches etc of dielectric strength 50 KV and above as per IS specification complete all as specified and directed.
S&F in repair HT bushing rod complete with insulator and packing suitable for out door/Indoor type transformers of capacity up to 200 KVA, confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet complete all as specified and as directed.
All as per item No 14 here in before but suitable for transformers of capacity 400 to 500 KVA complete all as specified and as directed.
All as per item No 14 here in before but suitable for transformers of capacity 600 to 630 KVA complete all as specified and as directed.
All as per item No 14 here in before but suitable for transformers of capacity 1000 KVA complete all as specified and as directed.
S&F in repair LT bushing complete with insulator and packing suitable1100 volt grade complete with nut bolts, brass studs, insulator and gasket etc suitable for out door/Indoor type transformers of capacity up to 200 KVA complete all as specified and directed.
All as per item No 18 here in before but suitable for transformers of capacity 400 to 500 KVA complete all as specified and as directed.
All as per item No 18 here in before but suitable for transformers of capacity 600 to 630 KVA complete all as specified and as directed.
All as per item No 18 here in before but suitable for transformers of capacity 1000 KVA complete all as specified and as directed.
S&F in replacement tap changing switch suitable for operation on HT 11 KV with tapping on +2%, 5%, and 7% on required basis suitable for 500 to 1000 KVA transformer complete all as specified and as directed.
Maintenance/servicing of existing transformer from 200 KVA to 1000KVA including following work/operations to the entre satisfaction of Engr-in-Charge complete all as specified and as directed:- (a) Opening of top plate after disconnection from HT/LT side. (b) Decaning of old transformer oil & keeping it for reuse after centrifusing to required dielectric strength as per IS schedules. (c) Checking maintenance of all internal parts as HT/LT coils of all places, HT bushing, internal electrical connections, tap changing gear box. (d) Internal cleaning of tank, cooling tubes free from sludge deposition. (e) Tightening of each bolts/nuts. (f) Refilling of oil after repairs / maintenance work. (g) Change of cork Gasket of top cover. (h) Tightening of core. (j) Assembly of complete transformer. (k) Taking meggar value by applying not less than 5000 Volts meggar on HT side and not more than LT side from 500 Volts meggar & recording results. (m) Change of silica jel and glass of oil level indicator of cover both. (n) M & L for painting to transformer of any capacity from outside with one coat of synthetic enamel paint grey colour after cleaning and preparing the transformer surface.
Supplying, erection & Fixing in replacement, Steel Tubular Pole 410 SP-55 (11 metres long) complete with cast iron base plate, finial taper plug, nuts, bolts and washers all as specified in IS including the followings complete all as specified and as directed:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level complete all as specified and directed. (c) Providing PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including necessary form work for plinth block/collar above GL complete all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work complete all as specified and directed. (e) Painting of Poles with one coat of red oxide primer and one coat of aluminium paint before fixing and one coat of aluminium paint after fixing. The complete embedded portion shall be painted with two coats of black bituminous paint.
M&L for painting of Panels after cleaning the body surface of panel by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl writing SM No/MES No as per existing pattern complete all as specified and directed.
M & L for Serving of OCB/VCB Including checking tracking, arcing, or thermal or physical damage, ensure that all contacts are clean, smooth, and in proper alignment, Clean all ceramic materials of loose dirt and examine for signs of moisture, make sure the assemblies are clean and dry complete all as specified and directed.
S&F in replacement local remote switch for vacuum circuit Breaker as per existing make and model complete all as specified and directed.
S&F in replacement Vacuum interrupter bottle suitable for 11 KV, VCB, 630 Amps capacity as per existing make all as specified and directed. Make : model No Siemens model No- S R No 1562087/ CG S No- 2224 VG/ABB S No-175892H
Removing ammeter from HT panel, 11 KV, by disconnecting electric connections and S&F new ammeter, 3 phase, digital type suitable for CT ratio 30/5 as per existing make and model including cable connections complete all as specified and directed. Make : AE/IMP/MECO
All as per item No 29 here-in-before but suitable for CT ratio 15/5 as per existing make and model including cable connections complete all as specified and directed. Make : AE/IMP/MECO
S&F in replacement ON/OFF circuit breaker switch with complete internal mechanism of 11 KV VCB/Bus coupler installed at main power house of as per existing model including complete mechanism like moving / fixed contact charging motor, charging gear from authorised rep of Existing Make complete all as specified and directed.
S&F in repair battery bank of capacity 24 volt consisting of (02 Nos each of 12 V maintenance free battery of 120 AH capacity (Make Exide/Amron/Luminous ) with replacement of battery bank of capacity 24 V, consisting of (12 Nos) of 02 Volts Each 120 AH maintenance free (Make : Exide/Amron/Luminous) for system voltage 24 V, including disconnection and removing of old unserviceable Battery bank complete all as specified and directed.
Dismantling, disconnecting, defective Ring main unit of capacity of 200 Amp, 11 KV for repair , opening up for inspection to assess the repairs required, and to carry out the repairs, opening of the unit, taking out compound and transformer oil, cleaning of oil tank, cable, boxes, repairs/ replacement of spares required including filling of new transformer oil and new HT compound, cleaning greasing and overhauling including taking out and replacement of unserviceable / worn out parts with new parts, fixing parts, re-assembling after repairs, bringing back to the location from where equipment was dismantled, fixing in original position, connecting, installation and testing on full load capacity and commissioning to the entire satisfaction of Engineer-in-Charge complete all as specified and directed. Note: 1. Spare parts shall be measured and paid separately under respective items of this schedule as S&F in replacement. These shall be identical to those specified by original manufacturer. 2. Unit rates quoted by tenderers shall deem to include for, volts, washers, lugs, thimble, wires and petty items required for efficient and smooth functioning of the equipment without any extra cost to the Govt.
M &L for Repair to ring main tee non expandable type one VL two OD with fault making and breaking isolator, complete replacement of main insulator, bus bar and joint with fish plate gaskets and one No. fuse carrier assembly HT 11 KV suitable up to 20 Amps of existing model S No- 2663 and 2664/2666 complete all as specified and directed.
S&F in replacement HRC fuse for Ring main unit , HT 11 KV, 10 to 16 A capacity, of existing make and model complete all as specified and directed.
S&F in replacement fuse carrier assembly with HRC fuse suitable for Ring main unit 20 Amps unit HT 11 KV as per sample complete all as specified and directed.
M&L for boring under road by using trenchless technology for passing of GI pipe/cable up to 100 mm dia complete all as specified and directed.
S&F in replacement post insulator for air break switch with metal part suitable for HT 11KV confirming to IS 5572-1972 complete all as specified and directed.
S&F in replacement DO fuse element of capacity 25 Amp to 50 Amp (20 Nos for each box) for 11 KV grade complete all as specified and directed.
S&F in replacement DO fuse element of capacity 5 Amp to 20 Amp (20 Nos for each box) for 11 KV grade complete all as specified and directed.
S&F in replacement fuse wire 200 Amps complete all as specified and directed.
S&F in replacement fuse wire 100 Amps complete all as specified and directed.
S&F, installing, testing and commissioning in replacement gang operated air-break switch, triple pole off load, with drop out fuse set insulator, mounted on channels outdoor, vertical mounting type HT 11KV, 50 Hz of rating 400 Amps, ISI marked, mechanically operated, mounted on insulators and frame work with operating mechanism worked from ground level with adequate length of GI pipe 32 mm dia medium grade , and locking arrangements including , complete with fuse mounts, fuse carriers and HT fuse elements having suitable rating in respect to load , necessary electric connections, complete all as specified and directed.
M&L for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals for 50 Sqmm 3½ core to 400 Sqmm of LT/HT cable to pole/LT panel/ main switch complete all as specified and directed.
Readjustment, cleaning of contact, greasing and testing of out door type air break switch 11 KV current rating up to 400 Amps including all materials required for alignment for AB switch in position and replacement of unserviceable parts complete all as specified and directed. Note : Replacement of unserviceable parts shall be measured and paid separately under relevant items of this Schedule.
M&L for attending major break downs on HT/LT lines, UG cables including, replacement of insulators/conductors/cross arms & laying of temporary cables etc complete all as specified and directed. Note: 1. items used shall be measured & paid separately under relevant item of this Schedule. 2. The contractor shall immediately attend break down on short notice as & when required with T&P and transport on receipt of information in required to breakdown on the direction of Engineer in charge. 3. If contractor fails to attending break down with in 2 Hour, a penalty of Rs 2000.00 shall be imposed on the contractor for every break down per Hour.
Repairs/maintenance of 11KV HT VCB Panel including bus coupler of any type, size and capacity complete including the following complete all as specified and directed:- (a) Taking out 11KV HT VCB of 400/630/800 Amps rating trolley from HT Panel after switching off electric supply. Checking of mechanical system for proper functioning of upward/downward movement of HT VCB trolley including opening the VCB & checking the quality of insulating. Cleaning & servicing the fixed/ moving contact & blowing out dust and applying the proper lubrication/ greasing and reassembling the VCB connection to HT panel complete. (b) Taking out all types of relay from HT11KV VCB panel and cleaning the contact and adjust the contact. Calibration all type of relay i.e. master tripping relay, earth fault tripping relay, over current, over voltage relay, circuit supervision relay etc through relay testing kit & proper plug setting as per required load & time delay and fixing the relay set in HT panels complete all as specified and directed.
M&L for repair/maintenance of bus bars inside HT 11 KV panels, by removing old burnt out insulation tapes and dust layers, cleaning with CRC/thinner and drying properly, Insulating the bus bars with HT 11 KV insulation tapes making arrangements for dust and vermin proof to the HT 11 KV panels at different locations complete all as specified and directed.
S&F in replacement indicator LED lamp for RYB phases complete all as specified and directed.
Disconnecting electrically & mechanically outdoor transformers of capacity 315 KVA to 630 KVA, lowering down/getting out from plinth carefully for repairing /making of plinth of transformer and re- connecting electrically and mechanically after repairing/making of plinth/Foundation, testing and commissioning complete all as specified and directed. Note: The rates quoted shall deemed to be included the cost of necessary labour charges and materials for repairs of plinth/Foundation work.
Disconnecting electrically & mechanically indoor/outdoor transformers up to 250 KVA capacity, lowering down/getting out from plinth, 4/6 pole Structure carefully for prevent/stopping for leakage of transformer oil (at site/sub station) including opening of top cover, draining out transformer oil and other items and storing the oil in suitable container (container to be provided by the contractor to keep aside for re -use, including replacement of all unserviceable gasket, after repairing/stopping of oil leakage the same re-connecting electrically and mechanically, testing complete all as specified and directed. Note: The rates quoted shall deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, T&P, gasket, opening/closing of top cover by unscrewing nut, bolts washers etc.
All as per item No 51 here in before but of capacity 315 KVA to 630 KVA complete all as specified and directed.
All as per item No 51 here in before but of capacity 750 KVA to 1000 KVA complete all as specified and directed.
S&F 3mm thick Sheet glass (each not exceeding 0.9 Sqm) ordinary quality and glazing with oil putty on cabin of OTI and WTI gauge of transformer up to capacity 1500 KVA complete all as specified and directed.
S&F Thermometer of transformer up to capacity 1000 KVA complete all as specified and directed.
S&F in replacement (at site/workshop), Porcelain Transformer bushing on LT (440 Volt) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity up to 250 KVA and re-connecting electrically and mechanically, testing complete all as specified and directed. Note: The rates quoted shall deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, opening of top cover by unscrewing nut, bolts washers and suitable size pad type bus bar aluminium and nut bolt washers etc.
All as per item No 56 here in before but of capacity 315 KVA to 630 KVA complete all as specified and directed.
All as per item No 56 here in before but of capacity 750 KVA to 1000 KVA complete all as specified and directed.
S&F in replacement (at site/workshop), Porcelain Transformer bushing on HT (11 KV) side, including brass stems conical bush and gasket after disconnecting electrically and mechanically for indoor/outdoor transformer of capacity up to 250 KVA and connecting electrically and mechanically, testing complete all as specified and directed. Note: The rates quoted shall deemed to be included the cost of necessary labour charges for draining out & re-filling transformer oil, opening of top cover by unscrewing nut, bolts washers and suitable size pad type bus bar aluminium and nut bolt washers and reconnection.
All as per item No 59 here in before but of capacity 315 KVA to 630 KVA complete all as specified and directed.
M&L for dismantling carefully and complete overhauling of the HT side (primary winding/Secondary windings) of the transformer burnt out winding with copper winding wire of suitable gauge including turn ratio or to match the existing including refixing, connecting, testing and commissioning the transformer complete including carrying out all the tests after rewinding of transformer complete all as specified and directed.
All as per item No 61 here in before but LT coils with super enamelled copper wire strip/DPC of high quality duly matching with the existing gauge and impedance complete all as specified and directed.
M&L labour for alternative arrangement by hiring, transportation of transformer of capacity up to 250 KVA in place of unserviceable transformer on hire basis for 15 days including, installation, connecting and testing of transformer and return back after installation of repaired transformer complete all as specified and directed. Note: (i) Repairing of transformer have to be completed within 15 days no extra cost will be paid toward hiring charges beyond 15 days . Moreover contractor shall not be allowed to shift the hired transformer until it is replaced by the repaired transformer. In case any fault /burning /peeling of painting and any other defects occurred in hired transformer the contractor shall have to made good himself from his own expenses. (ii) Contractor shall check the available infrastructure and to be sure regarding safety of hired transformer before installation . The rete quoted shall deemed to be include transportation cost, earthing lead etc. (iii) In case the defective transformer not repaired & installed on its site within the specified period of 15 days from the date of handing over to contractor, a panel recovery @ Rs 2000 /- per day shall be charged from his dues. During this period contractor shall not be allowed to shift the hired transformer until it is replaced by the repaired transformer . No extra cost beyond 15 days shall be paid to contractor on this account.
(b) M& L for transportation of repaired transformer to the original position (from where taken-down), disconnecting the alternative transformer, taking down the same, Re-installation of repaired indoor/outdoor transformer on 4/6 pole structure/plinth/inside sub station, connecting electrically and mechanically, testing and commissioning complete all as specified and directed. (c) The contractor shall give written warranty of two year from the certified date of completion for the repaired transformer. Note:- HT/LT leg coils and transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule.
All as per item No 63.00 here-in -before but capacity of transformer 315 to 630 KVA complete all as specified and as directed.
All as per item No 63.00 here-in -before but capacity of transformer 1000 KVA complete all as specified and as directed.
Disconnecting electrically and mechanically indoor/outdoor transformer capacity up to 630 KVA from HT/LT terminals and lowering down/getting out from 2/4/6 pole structure/plinth or inside sub station for major repairing/minor repair complete all as specified and directed.
M&L for transportation of unserviceable transformer of capacity up to 630 KVA from site to workshop and return back for installation it on original position/location after repairing from workshop (Rate shall deemed to be inclusive of transportation, T&P and man power) complete all as specified and directed.
All as per item No 67.00 here in before but of capacity above 750 KVA to 1000 KVA complete all as specified and directed.
Shifting of serviceable transformer of capacity up to 1000 KVA from MES store Yard/Sub Station (indoor/outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer complete all as specified and directed.
M&L for painting of transformer of capacity up to 250 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed.
M&L for painting of transformer of capacity 315 to 630 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed.
M&L for painting of transformer of capacity 750 to 1000 KVA with existing colour, with spraying machine, after cleaning, preparation of outer surface of transformer, including writing of SM No, MES and capacity of transformer complete all as specified and directed.
Disconnecting electrically & mechanically outdoor transformers up to 1000 KVA capacity, lowering down/getting out from plinth carefully for repairing /making of plinth of transformer and re- connecting electrically and mechanically after repairing/making of plinth/foundation , testing and commissioning complete all as specified and directed. Note:- The rates quoted shall deemed to be included the cost of necessary labour charges and materials for repairs of plinth/foundation work.
M&L for cleaning of 4/6/8 pole structure /surrounding area of outdoor transformer manually without damaging any equipments, cable , removing of dusts/grass/herbs etc complete all as specified and directed.
M&L for carrying out load balance distribution on LT side by checking the existing load on the feeder (3 phase, 4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load complete all as specified and directed. Contractor shall submit reports before load balance and after load balance as per format given by Engr-in-Charge.
S&F in replacement Male Contacts for air break switch contact complete all as specified and directed.
S&F in replacement Female Contacts for air break switch contact complete all as specified and directed.
M&L for pipe earthing (PIP) comprising of GI pipe 80mm Dia (Heavy duty), 3 Mtr long, with one bag of BFC (50 Kg) as per IS 3043-1987 tubing filled with jelly earthing compound duly inserted in soil boring of 100mm bore filled with back filled compound including fibre chamber cover 1x1feet openable type complete all as specified and directed. Note : On testing after completion, if the earth resistance < 2 Ohms is not obtain earthing will be rejuvenated at no extra cost to department till the desired earth resistance shall obtain.
S & F 630 Amp MCCB 4 Pole, 50 KA including necessary sheet metal enclosure of size 0.15 x 0.125 x 0.125cm made out of 1.6 mm MS sheet duly powder coated with necessary copper cable for & flexible PVC conduit for internal connection for distribution complete all as specified and directed.
All as per item No. 79.00 here in before but 400 Amp MCCB TPN 35 KA complete all as specified and directed.
S&F repair in MCCB 4 pole 415V adjustable, 250Amps with breaking capacity of 35KVA including cable connections in existing panel complete all as specified and directed.
All as per item No.81.00 here in before but 200 Amps breaking capacity of 35 KA complete all as specified and directed.
All as per item No.81.00 here in before but 100 Amps adjustable thermal & adjustable magnetic setting (breaking capacity of 35 KA) complete all as specified and directed.
S & F cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm, 3 core complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed .
Supply and laying clean dry sand for cable cushion including gently punning all as directed & specified. (Punned thickness shall only be measured).
Taking down old Broken Bricks any type from the trenches etc and M&L for burnt brick sub class ‘B’ laid in trenches abutting each other width equal to length of bricks complete all as directed.
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each layer all as specified and directed.
Removing the surplus soil to a distance 50 mtrs and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
M&L cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5 to 4 core XLPE armoured AL conductor cable of size 70 to 120 Sqmm complete all as specified & directed.
Disconnection terminal of LT cable and locating pin point fault in LT cable 1100V grade of any size including to & pro hire charge of special T&P complete all as specified & directed.
Disconnection terminal of HT cable and locating pin point fault in HT cable 11000V grade of any size including to & pro hire charge of special T&P complete all as specified & directed.
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 630 Sqmm single core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
S&F in repair On load change over switch of 800 Amp capacity 4 pole by pass switch with MS Encloser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0800 or equivalent model of L&T / Schneider/HPL
S&F in repair On load change over switch of 1000 Amp capacity 4 pole by pass switch with MS Encloser made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick channel floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO1000 or equivalent model of L&T / Schneider/HPL
Repairing of Battery Charger 24 V, 10 Amp for DG Set complete with suitable size of transformer, Rectifier, Fuse, on Off indicator, Electronic card etc. complete all as specified and directed.
S&F in repair HT terminal protector 3 core 11 KV up to 95 to 300 Sqmm Size Right Angled Cold Applied Boots complete all as specified and directed. Make- 3M/M-Seal/Raychem
Supply only in repair Scotch 23 Self bonding Electrical Tape High and low voltage insulation, self fusing rubber tape 1. Polyethylene (high and low density) 2. Cross-linked Polyethylene (XLP) 3. Polyvinyl Chloride (PVC) 4. Butyl Rubber 5. Ethylene Propylene Rubber (PVC) 6. Oil-based rubber, Primary electrical insulation for splicing cable from 600 volts through 69,000 volts on all solid dielectric cables, thickness -30 mils (0.76 mm), Tensile Strength* 8 lbs/in (1,4 KN/m), Ultimate Elongation* 1000%, Operating Temperature194°F (90°C), size (38mmx9.15mmx0.75mm) complete all as specified and directed.
Supply only in repair HT Tape 25mmx5 mtrs complete all as specified and directed. . Make Pidilite/3M/Raychem
Supply only in repair Tape 25mmx50 mtrs complete all as specified and directed. Make Pidilite/3M/Raychem
Supply, laying and connecting in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, HT underground cable ISI marked with aluminium multistranded conductor 11000 volt grade of size 95 Sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Taking down existing rusted/worn out MS cross arm, angle, clamps, nuts, bolts and washers and supply and fixing new MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated including painting with two coats of aluminium paint over and including a coat of red oxide primer to match it with existing surfaces complete all as specified and directed.
S&F (in replacement) anti climbing device, spikes type, fabricated out of mild steel bars of size 16 Sqmm (round, square and flat) including MS Flat 32x6mm, nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole including painting with two coats of aluminium paint over and including a coat of red oxide primer to match it with existing surfaces complete all as specified and directed.
M&L for preparation of old painted surfaces of two/Four pole Structure complete for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminium paint and painting of bottom area of pole up to 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
M&L for removal of bushes by cutting, removing vegetation, garbage, waste materials etc from site making approach way to valve pits, pipe lines, FP Boxes and cleaning the surroundings of installations complete all as specified and directed.
Supply, installation, testing and commissioning in repair stand by and commercial power supply monitoring panel with addition and alteration and necessary power and control wiring in existing AMF panels for diesel Engine driven generating set of 320 KVA to 63 KVA range capacity 3 phase, 4 wire, 415 V directly to alternator mounted with following controller and accessories complete all as specified and directed: -
(A) AMF PANEL Controller:- Supply, fixing, testing and commissioning in repair Auto main failure (AMF) panel Auto/Manual switch -01 No. along with AMF Digital controller SCADA compactable with inbuilt RS 485 Port & Communication cable of Make : Procom Model No ECON-A-322 (HSN :85030010 or equivalent in Deepsea/ Wood ward) with connected control and power wiring and other modification as required to monitor and control all AMF parameter in above said controller all as specified and directed.
Supply, Installation, Testing & Commissioning in repair of SCADA Panel with all necessary spares DG set control panel . The said SCADA unit shall be capable of acquiring the data from various relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit shall be able to perform bidirectional communication for future use. The system shall be mounted in a panel of size 400mm x 400mm x 200mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at site and, and shall be consisting of following:- (A) DG Set SCADA panel for 320 KVA to 63 KVA range DG Set :- Supply, Installation, Testing & Commissioning in repair of SCADA panel with all necessary spares for installation on Diesel Generators . The said SCADA unit must be capable of acquiring the data from various relays/ meters/ breakers etc., conditioning data for transmitting, transferring data through RTU to the cloud server. Also, the unit should be able to perform bidirectional communication for future use. The system shall be mounted in a panel of size 400mm x 400mm x 200mm (minimum) fabricated from 1.6mm thick CRCA sheet and must be powder coated. It shall be installed at site and, and shall be consisting of following complete all as specified and directed:-
SCADA Software for DG Set Panel shall be inclusive of following :- Software with 5.0 years subscription, maintenance and support as per specification:- Must have user customizable dashboards and SLD (without any coding/ scripting) Reporting must be user-configurable and changeable. Utility like billing reports must be supported. Multi-site data viewing within same interface without any physical cable connection of sites to SCADA room SCADA must be accessible over internet and must have adequate security with dual factor authentication with username/ password along with OTP on email. All device communication with Cloud based SCADA must be secured using TLS/SSL encryption. SCADA must not support non-secure connections. System must work without any need of static IP. No static IP will be provided for any location.
Controller shall be looped with RS485 Modbus RTU compatible DG AMF relay by using RS485 cable of Belden/ Lapp makes. Other necessary power cabling to power the controller is in the scope of this tender.
Supply, installation, testing and commissioning in repair with system validation and subscription/ package from any 4G/3G/GPRS provider OEM for RTU Installed in DG set AMF panel complete all as specified and directed with following features:-
(a) 4G/ 3G/ 2G SIM cards for 5 years subscription. Data services shall be from at least two reliable service providers and system should support automatic switching to 2nd service provider in case of low network without any intervention. System should support changing of service providers without changing SIM cards (future ready).
SANJEEV ENTERPRISES
BLUE HILL ELECTRICAL AND ELECTRONICS
M/s Birja Nand
Ridhi engineers and builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .