| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.5 L+₹5.1 L (19.2%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹33.7 L+₹7.3 L (27.5%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹35.6 L+₹9.2 L (34.7%)Rejected-AOC 2 4 136 4TH BLOCK LINGA REDDY MANSION OPP TARBUND SECUNDERABD TARBUND SECUNDERABAD TELANGANA 500009 | HYDERABAD | TELANGANA | 500009 | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹36.1 L+₹9.7 L (36.6%)Rejected-AOC | L5 | Rejected-AOC Not being L1 |
Tender Value
₹39.4 L
EMD Value
₹78,800
Closing Date
10 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
PROVISION OF LT RING MAIN SYSTEM FOR ICU, OT, OFFRS FAMILY WARD, JCO/OR FAMILY WARD AND EMERGENCY OF MH SECUNDERABAD UNDER GE (U) SECUNDERABAD
2022_MES_563097_1
GE(U)/SEC/TOKEN/49 OF 2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
SECUNDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹78,800
Yes
15 Jun 2023
14 Nov 2022
17 Dec 2022
14 Nov 2022
10 Dec 2022
28 Nov 2022
Amount
Design , Supply, Installation, testing and Commissioning CPRI APPROVED factory fabricated, out door type, LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers , cable glands of appropriate size , etc. and supported with 65X65X6mm Mild Steel Angle Iron Frame and 500 mm above ground lavel , embeded in PCC 1:2:4, type C-2, 45 Cm below ground level and 50 Cm above ground level complete with internal connection with suitable size of strip ,cable lugs,and cable glands and Test-ing after Installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.2 M X1.8 MX0.40M)
(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 400 Amps for phases and Neural, set of 4 for RYB &N - 01 set. (b) MCCB 4 Pole 200 Amps 36KA -01 No. Thermal Magnetic release (incommer) (c) MCCB 4 Pole 160 Amps 36KA -01 Nos. (Outgoing) (d) MCCB 4 Pole 125 Amps 16KA -04 Nos. (Outgoing) (e) MCCB 4 Pole 32 Amps 16KA -05 Nos. (Outgoing)` (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set (h) Changeover switch 320 amps 4 pole - 01 No
Design , Supply, Installation, testing and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers , cable glands of appropriate size , etc. and supported with 65X65X6mm Mild Steel Angle Iron Frame and 500 mm above ground lavel , embeded in PCC 1:2:4, type C-2, 45 Cm below ground level and 50 Cm above ground level complete with internal connection with suitable size of strip ,cable lugs,and cable glands and Test-ing after Installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.15 M X1.5 MX0.40M)
(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 300 Amps for phases and Neural, set of 4 for RYB &N - 01 set. (b) MCCB 4 Pole 160 Amps 36KA -01 No. Thermal Magnetic release (incommer) (c) MCCB 4 Pole 125 Amps 16KA -01 Nos. (Outgoing) (d) MCCB 4 Pole 63 Amp 16 KA-04 Nos (Outgoing) (e) MCB 4 Pole 32 Amp 16 KA-03 (Outgoing) (f) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (g) Indicating type lamp for Red, Yellow and Blue phases - 01 Set (h) Changeover switch 200 amps 4 pole - 01 No
Design , Supply, Installation, testing and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers , cable glands of appropriate size , etc. and supported with 65X65X6mm Mild Steel Angle Iron Frame and 500 mm above ground lavel , embeded in PCC 1:2:4, type C-2, 45 Cm below ground level and 50 Cm above ground level complete with internal connection with suitable size of strip ,cable lugs,and cable glands and Test-ing after Installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.5M X1.0MX0.35M) :-
(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 200 Amps for phases and Neural, set of 4 for RYB &N - 01 set. (b) MCCB 4 Pole 63 Amps 16 KA -01 No. Thermal Magnetic release (incommer) (c) MCCB 4 Pole 32 Amps 16 KA -05 Nos. (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set (f) Changeover switch 100 amps 4 pole - 01 No
Design , Supply, Installation, testing and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX IP 55 protection grade, made out of 3.15 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers , cable glands of appropriate size , etc. and supported with 65X65X6mm Mild Steel Angle Iron Frame and 500 mm above ground lavel , embeded in PCC 1:2:4, type C-2, 45 Cm below ground level and 50 Cm above ground level complete with internal connection with suitable size of strip ,cable lugs,and cable glands and Test-ing after Installation complete all as specified and comprising of the following :- (Size of the panel board should not be less than 1.25 M X2.25 MX0.40M)
(a) Bus bar aluminium duly insulated with colour coded heat shrinkable sleeve and mounted on suitable size of 'F' class insulators made of non hygroscopic, non combustible, track resistant high strength FRP insulators 650 Amps for phases and Neural, set of 4 for RYB &N - 01 set. (b) MCCB 4 Pole 400 Amps 36KA -02 Nos. adjustable type (incommer) (c) MCCB 4 Pole 315 Amps 36 KA -02 Nos. (Outgoing) (d) MCCB 4 Pole 200 Amps 25KA -03 Nos. (Outgoing) (e) MCCB 4 Pole 100 Amps 16 KA -03 Nos. (Outgoing) (f) MCCB 4 Pole 63 Amps 16 KA -02 Nos. (Outgoing) (g) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 630/5A LT-CT operated complete - 01 Set (h) Indicating type lamp for Red, Yellow and Blue phases - 01 Set (j) Changeover switch 630 amps 4 pole - 01 No
Notes for item Nos 1 to 4.02 : Quoted rates inclusive of the following : (a) All incoming and out going cables are to be connected to the above panels with proper lugs, double compression copper stain less steel armoured cable gland, nuts, bolts etc the cost of the items deemed to be included in the quoted rates. (b) Make of MCCB's and MCB's to be used in the panels are : L&T / Legrand/Siemens/C&S as approved by GE. (c) The panel shall be Fabricated from a reputed firm (CPRI Approved) . (d) All Internal connection between ACB, MCCB ( ABOVE 63 AMPS ) and Changeover and Bus bar shall be done by aluminium strip of suitable size and capacity . (e) All MCCB to be connected with both side Spreader Link And All Incomer and outgoing MCCB of Panels should be thermal magnetic release with adjustable settings ( Min 70 5 to 100 %) and Ics = 100% Icu
(f) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board.( Minimum space for MCCB up to 200 amps = 35 CM , Minimum space for MCCB 250 to 400 amps = 45 CM , Minimum space for MCCB above 400 amps = 55 CM ) (g) Base of the panel should not be less than 500 mm above the ground level. Necessary PCC for base /foundation required deemed to be included in the quoted rate. (h) Cable alley / chamber to along with connector of suitable size to be provided for connection of Out going cable . (j) Necessary approval of drawing to be taken from GE before placing order to the manufacturer. (k) All existing incoming and out going cables also to be connected to the above panel as per site requirement with proper lugs, glands nuts, bolts etc (l) Door hinge of industrial type heavy duty to be provided minimum 3 Nos for each door (m) The rate shall deemed to be include in the item rate for al the points mentioned above.
Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed
All as per item No:5 above but 3.5 Core 50 Sqmm
All as per item No:5 above but 3.5 Core 70 Sqmm
All as per item No:5 above but 3.5 Core 95 Sqmm
All as per item No:5 above but 3.5 Core 120 Sqmm
All as per item No:5 above but 3.5 Core 150 Sqmm
All as per item No:5 above but 3.5 Core 185 Sqmm
Supply and lay pipe galvanized, “ Light grade”, including fittings, 40mm dia.for protection of cable complete all as specified and directed
Supply and lay pipe galvanized, “Light grade”, including fittings, 50mm dia.for protection of cable complete all as specified and directed
Supply and lay pipe galvanized, “Light grade”, including fittings, 80mm dia.for protection of cable complete all as specified and directed
Supplying and laying of following size HDPE pipe PN 10 ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground , wall , floor complete all as directed
Cutting the existing road / hardstanding straight by manual, depth and width not less than 0.6 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. Note : Quoted rates are deemed to be inclusive of PCC.
Cutting the existing building plinth protection/ Floor by using suitable cutter , depth and width as required for laying of LT UG Cable of any size /any kind of pipes pipes up to 50 mm dia and making good of disturbed surface shall be made with cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) and cement morter on any other things as required to match with the adjoining surface complete all as specified and directed.
S&F on wall with necessary arrangements busbar chamber 100 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates are deemed to be inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
S&F on wall with necessary arrangements busbar chamber 200 amps 4 way 4 pole wall mounted IP -31 , made out of 1.6 mm thick CRCA sheet epoxy powdwer coated single layer operational voltage 440 Volt , Short circuit current capacity 25 KA for 1 Second including necessary cable connections complete all as specified and directed. Note: Quoted rates are deemed to be inclusive of necessary fixing arrangement and cable connections , cable glands as required for proper fixing / functioning of Bus Bar Chamber.
S&F MCCB box made of CRCA sheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall byusing anchor bolt comprising MCCB 63 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
S&F MCCB box made of sheet of 2mm thick size 40X30X20 CM Powder coated Suitable for fixing at Pole including two set of clamps / wall byusing anchor bolt comprising MCCB 100 Amps 16 KA FP WITH BOTH SIDE SPREADER LINK complete all as specified and directed.
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, HDPE pipe upto 110 mm dia of max length 15 m including jointing materials to carry LT UG cables of size upto 240 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed including refilling and making good of disturbed surface . Note : Quoted rate is deemed to be exclusive of HDPE pipe but inclusive of necessary machinaries required for the above work
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.
Earth work in excavation by mechanical means in trenches in all kind of soil not exceeding 1.5 m in width including dressing of side , lift upto 1.5 m including getting out the excavated soil for laying of LT UG cable and disposal of surplus excavated soil as directed
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e. 18 cm) shall be measured for payment.
Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all asspecified and directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with pipe of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m. The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM). The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification. GI Electrode Shall be tested from CPRI. The earting pit should be cover with PCC 1:2:4, B1 cover of 300 x 300 mm complete all as specified and directed.
Supply and Install Auto transfer switch 400 amps 415 volt 4 pole including all necessary arrangement complete all as specified and directed
Supply and Install Auto transfer switch 200 amps 415 volt 4 pole including all necessary arrangement complete all as specified and directed
Supply and Install Auto transfer switch 100 amps 415 volt 4 pole including all necessary arrangement complete all as specified and directed
SANJEEV CONSTRUCTIONS
L and S ENTERPRISES
omsai thermax engineers
Srinivash Engineers
POWER CONSTRUCTION COMPANY
LEOENTERPRISES
OM INFRA
Srinivasa Consructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .