Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹51.1 L+₹3.3 L (6.80%)Rejected-Finance | L2 | Rejected-Finance L2 FOR REJECTED |
Tender Value
Refer Docs
EMD Value
₹1.0 L
Closing Date
6 May 2021, 6:00 pmClosed
HQ COMMANDER WORKS ENGINEER SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CWE SGNR 100 of 2020-21 SPECIAL REPAIR TO WATER SUPPLY PUMP NO 02 AND ITS FILTRATION PLANT EXCLUDING RAW WATER TANK AT MILITARY STATION FARIDKOT (2ND CALL)
2021_MES_428637_4
CA NO. CWE SGNR - 100 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE FARIDKOT
Class-C
Category-a(ii)
10 documents required · 10 mandatory
₹1,000
Yes
₹1.0 L
Yes
11 Jun 2021
8 Apr 2021
8 May 2021
8 Apr 2021
6 May 2021
22 Apr 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles(if any) to store and rubbish off the premises complete all as specified as directed by Engr-in- Charge
S&F Glazed ceramic tiles (coloured tiles) in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 15 mm thick rendering in CM 1:4 on other than fair face of brick work complete all as specified as directed by Engr-in- Charge
S&F Non skid ceramic tiles 7 to 8 mm thick (square/rectangular) (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles 15mm thick screed bed or bedding layer CM 1:6 for laying finishes complete all as specified as directed by Engr-in- Charge
Taking down cement plaster on brick or stone wall etc. including raking out of joints, hacking for keys and scrubbing down with water complete all as specified as directed by Engr-in- Charge
M&L Rendering 15 mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement and Preparation of new surfaces plastered or unplastered and applying two coat of white wash on wall over on coat of primer complete all as specified and directed by Engr -in - charge.
M&L Rendering 15 mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including preparation of newly plastered or unplastered surfaces and applying two coat of cement base paint over one coat of primer complete all as specified and directed by Engr -in - charge.
M&L Rendering 10 mm thick in cement plaster 1:3 on ceiling finished even and smooth without using extra cement including Preparation of new surfaces plastered or unplastered and applying two coat of white wash on ceiling over one coat of primer complete all as specified and directed by Engr -in - charge.
M&L cement plaster and rendering 10 mm thick rough cast plaster in cement mortar (1:4) on fair of brick or concrete surface and applying two coat cement base paint over one coat of primer complete all as specified as directed by Engr-in- Charge
Demolition of concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified as directed by Engr-in- Charge
Surface dressing not exceeding 15 cm deep and getting out in soft/loose soil complete all as specified as directed by Engr-in- Charge
Hardcore of broken brick aggregate gauge not exceeding 63mm deposited spread and leveled in layers not exceeding 15 Cm thick watered and rammed to a true surface complete all as specified as directed by Engr-in- Charge
M&L for sand filling under floors or in foundations including watering and consolidationcomplete all as specified as directed by Engr-in- Charge
M&L Mild steel framed work of E-165(Fe-290) as in grills/guard bars shouldered with steel windows/ventilators frames,Cooler Stand, Ladder etc. including red oxide primer coat complete all as specified as directed by Engr-in- Charge
M&L for PCC 1:4:8 type D2 as in Foundation, filling , sub base (using 40 mm graded stone aggregate) complete all as specified as directed by Engr-in- Charge
M&L machine pressed precast concrete coloured interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade, with grey cement and pigment, complete all as specified as directed by Engr-in- Charge
Providing factory made precast cement concrete solid block type B1, 1:2:4 (20mm graded aggregate) as in kerb stone of any size/thickness setting in cement mortar 1:4 for path edgings etc, embedded in positon including all necessary excavation, tamping ground arround blocks and removal of rubbish/surplus soil complete all as specified as directed by Engr-in- Charge
Preparation of new concrete / plastered surface of any description, over 10cm width or girth and applying two coats of plastic emulsion paint including priming paints complete all as specified as directed by Engr-in- Charge
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete with glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
S&F factory made box type steel window with side hung shutters including box type hinges with steel handle and 2 Nos 150mm long mild steel tower bolt,fixing lugs etc complete without glazing bars dovetailed or welded complete all as specified and directed by Engineer-in-Charge.
Taking down of chowkats or frames n.exc 1.5 Sqm each with shutters (without taking of shutters from the frames) complete all as specified as directed by Engr-in- Charge
M&L preparation of new or previously untreated steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
M&L Cement concrete 50mm thick type C-2 (1:3:6) 20 mm graded stone agg) as in plinth protection/path finished and fair without using extra cement complete all as specified as directed by Engr-in- Charge
M&L for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in benching for manholes.bands,coping,bed plates including slightly rounded or chamfered angles including necessary formwork complete all as specified as directed by Engr-in- Charge
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars complete all as specified as directed by Engr-in- Charge
All as per item srl No 24 here before but for except bricks complete all as specified as directed by Engr-in- Charge
M&L for brick work with fly ash bricks (old size bricks) straight or curved on plan exceeding 6m mean radius with old size bricks in wall built in cement mortar (1:6) complete all as specified as directed by Engr-in- Charge
M & L for machine cut kota stone slab flooring 20-25mm thick over 20mm cement screed (CM 1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including rubbing and polishing complete all as specified as directed by Engr-in- Charge
M & L for kota stone slab 20-25mm thick in skirting laid over 15mm cement screed (CM 1:4) and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified as directed by Engr-in- Charge
M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings .complete all as specified (Paymentfor providing grooves shall be made separately) complete all as specified as directed by Engr-in- Charge
M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per pecifications and direction of the Engineer-in-charge
S&F in repair Rotational moulded polythylene 500 capacity water storage tank (Cylindrical vertical with closed top) hoisted and fixed in position including PVC float valve 20 mm bore, high pressure with polythene ball & float & dismantling of old water tankcomplete as per pecifications and direction of the Engineer-in-charge
M&L for Roof Treatment complete as per pecifications and direction of the Engineer-in-charge : (a) Cleaning, washing of surface and removing all existing bitumen coatings completely with intense wire brushing or high speed water jet. Surface should be free from any loose paint, dust or grease. (b) All cracks upto 3mm at corner joints, channels and parapets should be treated with crack seal and bigger cracks, damaged portions and hollow areas must be repaired with polymer modified cement mortars. (c) Applying one coat of PrimeSeal/ Epoxy Primer/ShaliUrethane BTD White diluted with potable water in the ratio of 1:1 and apply @ 0.40 kg/ sqm (0.20 kg BTD+0.20 Kg water) (d) Laying polyster reinforced fiber net/50 gsm Geotextile mesh, upto 300 mm on walls. (e) Applying three coat of HydroShield PUD microfibre reinforced UV resistent polyurethane (solid content 68% ) / Damp Proof ultra UV Stable fibre reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers (Solid content 55%)/ SmartCare PU Magnum elastomeric waterproofing coating based on hydrophobic polyurethane (solid content 85%)/Single Component Elastomeric Liquid Membrane ShaliUrethane BTD White/coloured (Elongation 400% ± 50, Solid Contents > 80% & Specific Gravity @ 30 OC 1.5 ± 0.03) @ total 2.00 Kg per sqm in two coats for maintaining thickness of 1.5mm, with paint brush/ roller upto 300 mm on walls. (f) The complete treatment to be carried out by authorised applicator of waterproofing manufacturer. Make : DrFixit/ Asian/STP Note : (i) The treatment shall be carried out as per the manufacturers instructions, and as directed by Engineer in Charge. (ii) The plan area of floor shall be considered for payment .
Taking down MCCB, MCB, DB TPN / SPN and making good to the disturbed walls and surface area etc all as specified and directed by Engr-in-Charge.
Taking down point wiring complete including fixture and fittings and making good to disturbed area all as specified and directed by Engr-in-Charge.
Taking down submain wiring 2 run / 4 run with earthing cable and making good to disturbed area all as specified and directed by Engr-in-Charge.
Point wiring complete with ISI marked 1.5 sqmm single core PVC insulated unsheathed cable 1100V grade FRLS with multistranded copper conductor drawn through concealed/surface in wall/roof/ceiling surface and its accessories on the surface etc includingincluding PVC rigid concealed conduit suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switchs, sockets, fan regulator etc covered with 2.8 mm thick plastic laminate Hylem top cover sheet of required color fixed with brass screws and cup washers painting terminal boxes inside and outside with one coat red oxide primer including fixing and 1.5 sqmm copper conductor as earth continuity to connect common earth dolly completed for One light point/Fan point/Exhaust point controlled by one way switch all as specified and directed by Engr-in-Charge:-
Description all as per Item srl No 36 here-in-before but for One three pin socket out let 5 amps on the same board with other switches complete as per pecifications and direction of the Engineer-in-charge
Description all as per Item srl No36 here-in-before but for One 3 pin, 5A switch socket outlet point on independent board complete as per pecifications and direction of the Engineer-in-charge
Description all as per item ser no. 36 here-in-before but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement PVC Lamp holder suitable for LED 5 to 20 watt blub complete all as specified and directed by Engr-in-Charge.
Supply and fixing LED bulb 1x10 Watt lamp having luminous efficancy warranty 2 year all as per specification & directed by Engr-in-Charge.
Supply and fixing of LED tube light fiting 20W, (4 feet long) 230 V, surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver and including connections up with copper conductor wire with suitable size as per specification and directed by Engineer-in-Charge.
M&L ceiling rose 3 phase / PVC / polycarbonate isolated body all as specified and directed by Engr-in-Charge.
M&L of submain wiring with two single core PVC FRLS insulated copper conductor 10 sqmm and same 10 sqmm for continuous earth wire drawn in to concealed PVC conduit complete all as specified and directed by Engr-in-Charge. Note: Cost of PVC conduit, conduit accessories and earth wire including in sub main wiring.
S&F Piano type switch single pole 1 way 5/6 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F socket two in one 3/5 Pin 5 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F Piano type switch single pole 1 way 15/16 amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F socket two in one 6 Pin 15/16 Amps 230 volt AC supply complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure for DB's SPN 230 volts 8 way with 200 amps rated bus bar, double door complete all as specified and directed by Engr-in-Charge.
S&F MCB SP 32 amps 230V 10 KA complete all as specified and directed by Engr-in-Charge.
S&F MCB SPN 32 amps 230V 10 KA complete all as specified and directed by Engr-in-Charge.
Earthing complete with galvanised steel earth plate electrode of size 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal GL connected to galvanised earth lead wire 4.0mm dia (8 SWG) by means of bolts, nuts, check nuts and washers and earth strip protected by 15 mm dia GI pipe medium grade and connected to main distribution board panel/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion all as specified and directed by Engr-in-Charge.
Supply and fixing LED street light 25 watt luminaries environment friendly, energy saving and long life med up of pressure die cast aluminium husing with high power LED as lighting source and lens embedded PC cover having top openinig seperate driver complete with IP 65 protection and impact resistance of IK07 including suitable size of GI Bracket and fixing arrangement in road light, security light etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable 1.5 sqmm with suitable size and including taking down defective unserviceable street light any size as per specification & as directed by Engr-in-chrg.
S & F fan regulator electronic socket /stepped flush type 5 speed for ceiling fan 1200/1400 mm sweep on the existing phenolic laminated sheet etc. complete all as specified and directed by Engr-in-Charge.
Removal filter media (gravel ,sand etc) upto bottom of water filter bed of water capacity 20000 gallons/hour one by one ,washing media,removing sludges,mud,clay and all foregin materials,setting aside usefull media for and replacement of deterioted /distorted media with new media of various specifications (media shall be measure and paid seperately) Note: one quote of black paint in whole filter walls and pipes and Refilling and relaying of old gravel and sand media is included in item rates quoted complete as per pecifications and direction of the Engineer-in-charge
Supply and laying filter media of screened graded sand/gravel laid ,stone gravel of size 2mm to 5 mm as directed and specified by Engineer in charge.
All as per Item No 2 here-in-before but size 0.5 mm to 1 mm complete all as specified and directed by Engineer-in-charge.
Supply and fixing Horizontal split casing type clear water pumping set comprising of totally enclosed fan cooled sqiirrel cage induction electric motor 30HP/22KW 3 phase ,415 volts 50Hz mounted (B3),continously rated (S1) with ambient 50 degC,F class insulation with tepm rise enclosed conforming to protection IP-55 ,horizontal foot limited to class B altitude less than 1000 m above m.s.i performance efficiencyvalues are conforming to IS 12615:2011 or IEC 60034-30-1-2014 fitted with horizontal split casing centrifugal pump MOC: C.I Impeller ,casing CI, shaft & sleeve SS suitable for 3840 LPM Min 18 METER head both directly coupledalong with coupling with MS common base frame. Make: Pump Kirloskar/wilo mather platt/KSB Make Motor: Kirloskar/crompton/ABB/Bharat billi
Supply and laying CI Pipes of size 80mm with spigot and socket ends centrifugally cast, class LA in any trenches complete as per pecifications and direction of the Engineer-in-charge
Supply & laying Ductile Iron pipe ( K-7) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 100mm dia complete all as specified and directed by Engr-in-charge.
S&F in replacement of sluice valve class PN-1.6, IS 14846 with brass spindle, flanged end of size 100mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape for Over Head tanks inlet & outlet pipes complete as per pecifications and direction of the Engineer-in-charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 with brass spindle, flanged end of size 80mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape for Over Head tanks inlet & outlet pipes complete as per pecifications and direction of the Engineer-in-charge
Supply & laying Ductile Iron pipe ( K-7) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 200 mm dia complete all as specified and directed by Engr-in-charge.
Supply & laying Ductile Iron pipe ( K-9) with spigot & socketed ends class LA rubber tightened joints type centrifugally cast of size 300 mm dia complete all as specified and directed by Engr-in-charge.
S&F in replacement of sluice valve class PN-1.6 14846 ISI marked with brass spindle, flanged end of size 300mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape complete as per pecifications and direction of the Engineer-in-charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 marked with brass spindle, flanged end of size 200mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape complete as per pecifications and direction of the Engineer-in-charge
Excavation in trenches n.exc 1.5 mtr width & n.exc 1.5 mtr in depth for foundation/pipe lines etc and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Returning filling in including spreading leveling watering & and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removing excavated material n.exc 50 mtr & depositing where directed at a level n.exc 1.5 mtr above the starting pointing complete all as specified and directed by Engineer-in-charge
S&F in replacement of sluice valve class PN-1.6, IS 14846 marked with brass spindle, flanged end of size 500mm bore including joint with rubber or fiber board gasket, nut bolts washers as per existing specification and body shape complete as per pecifications and direction of the Engineer-in-charge
S&F in replalcement of Non Return Valve PN 1.6 (Reflex valve) flanged end with by pass charged conforming to IS 5312, ISI marked supplied and installed complete of size 300mm dia flanged end ISI Marked with all fittings complete as per pecifications and direction of the Engineer-in-charge
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in curbs/coping/bed plates and the likes including weathering, slightly rounded or champhered angles with necessary use and waste of formwork for pipe support , finishing even and smooth without using extra cement complete as per pecifications and direction of the Engineer-in-charge
Dismantling valve pit of any size and construction of new brick masonry valve pit of size 1400x1400x1200mm (internal size) brick work in cement mortar1:4 over 100mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate, 20mm thick PCC coping 1:2:4 type B-1 using 20mm thick stone aggregate and internal plaster in cement mortar 1:4 and external plaster 1:6 with mild steel sheet cover 3mm thick and angle iron frame of size 50mm x50mmx6mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, M&L complete all as specified and as directed by the Engineer in charge.
M&L for CI fitting for spigot & socket pipes, bends, tapers tee pieces ,caps & plugs up to 300 mm bore of pipe complete all as specified and directed by Engineer-in-charge.
S & F Single phase preventer for any capacity of motors complete as per pecifications and direction of the Engineer-in-charge
S & F in replacement 50 mm bore cast iron air release valve flanged type with two air out lets and Including jointing material , such as nuts, bolts, washers and rubber sheet etc.complete all as specified and directed by Engr-in-charge.
Repair and servicing of fluculators assembly,oiling geasing of rotating and fixed arms,replacement of centeal thurst bearing,slip ring assembly ,repair servicing o fluculators shaft copmlete including MS stirrers and blowers all as specified and directed by engineer in charge.
S & F PVC cable of copper conductor 3 core submersible 50 Sqmm as specified and directed by Engineer in charge.
S&F in replacement of foot valve (Flanged) 300 mm dai confirming to IS 4038 including joint with rubber fiber board gasket, nut bolts etc complete all as specified & directed by Engineer-in-charge.
.S&F in replacement of foot valve (Flanged) 200 mm dai confirming to IS 4038 including joint with rubber fiber board gasket, nut bolts etc complete all as specified & directed by Engineer-in-charge.
S&F in replacement of foot valve (Flanged) 150 mm dai confirming to IS 4038 including joint with rubber fiber board gasket, nut bolts etc complete all as specified & directed by Engineer-in-charge.
Dismantling existing mild steel sheet covers of any thickness from existing size of pit with locking arrangements butt hinges handles and other connected items and fixed to exixting anglesiron frame complete all as specified and directed by engineer in charge.
S&F in repair Star delta starter fully automatic for 415 volts of capacity 125 HP ,complete as per pecifications and direction of the Engineer-in-charge
Taking up or down cast iron water mains inculding all fitting with spigot or socket ends and lead joints including burning out joints and removing lead for 80/100 mm bore pipes complete all as specified and directed by Engineer -in-charge.
All as per Item srl No 84 here-in-before but for 200 mm bore complete all as specified and directed by Engineer-in-charge.
All as per Item srl No 84 here-in-before but 300 mm bore complete all as specified and directed by Engineer-in-charge.
Taking up or down sluice valve inculding all fitting with spigot or socket ends and lead joints including burning out joints and removing lead for 80/100 mm sluice valvecomplete all as specified and directed by Engineer -in-charge.
Taking up or down sluice valve inculding all fitting with spigot or socket ends and lead joints including burning out joints and removing lead for 200/300 mm sluice valvecomplete all as specified and directed by Engineer -in-charge.
Taking up or down foot valve of size 150/200/300 mm inculding all fitting complete all as specified and directed by Engineer -in-charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil and making good disturbed surfaces complete as per pecifications and direction of the Engineer-in-charge
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete as per pecifications and direction of the Engineer-in-charge
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as per pecifications and direction of the Engineer-in-charge
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete as per pecifications and direction of the Engineer-in-charge
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete as per pecifications and direction of the Engineer-in-charge
Supplying and fixing Galvanised mild steel pipe /tubing, of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of following bore and as directed. (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately) complete as per pecifications and direction of the Engineer-in-charge
All as per Item srl No 95 here-in-before but for size 80 mm bore dia complete as per pecifications and direction of the Engineer-in-charge
Disconnecting & taking out defective under ground foulty cable from trenches, pole, pipe, floor ,wall etc for any size complete as directed by Engineer-in-Charge.
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 4 core ,complete all as specified laid in trenches/ laid , open air , existing duct , wall etc as per ground condition under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete as per pecifications and direction of the Engineer-in-charge Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per Item srl No 98 here-in-before but for size size 25 Sqmm 4 core complete as per pecifications and direction of the Engineer-in-charge
All as per Item srl No 98 here-in-before but for size 70 Sqmm 3.5 core complete as per pecifications and direction of the Engineer-in-charge
All as per Item srl No 98 here-in-before but for size 185 Sqmm 3.5 core complete as per pecifications and direction of the Engineer-in-charge
All as per Item srl No 98 here-in-before but for size 240 Sqmm 3.5 core complete as per pecifications and direction of the Engineer-in-charge
Supplying & fixing twin core , 4 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete as per pecifications and direction of the Engineer-in-charge
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on complete as per pecifications and direction of the Engineer-in-charge
Taking down of old unserviceable street light/ flood light any type etc. fittings and Supply, fixing and testing LED Flood light fitting of 160 Watt fitted on 9 & 11 Meter PCC/ Swan neck pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. all as specified and directed by Engineer-in-Charge. Make: Crompton/ Bajaj/ Polycab /Havells/Halonix/Philips /Lucker ---------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,53,377.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 33 (Schedule of Credit) of Tender document
OBEROI CONSTRUCTION CORPORATION
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .