Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.4 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹19.1 L+₹3.4 L (21.8%)Rejected-AOC | L2 | Rejected-AOC OK | |
| 3 | L3₹19.8 L+₹4.1 L (26.2%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹20.3 L+₹4.6 L (29.4%)Rejected-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L4 | Rejected-AOC OK | |
| 5 | L5₹20.4 L+₹4.7 L (30.0%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
30 Jan 2023, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
SPECIAL REPAIR TO REWIRING AND ALLIED WORK AT CERTAIN SMQs AT 51 ASP AF STN DIGARU.
2023_MES_574250_1
8601/E8 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
Please ref Tender Documents
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹38,000
Yes
6 Mar 2023
10 Jan 2023
1 Feb 2023
10 Jan 2023
30 Jan 2023
25 Jan 2023
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and cheasseling/ cutting wall for concealed point wiring with proper cementing work and making good disturbed surfaces of walls as existing colour of wall, floors, etc. complete all as specified and directed.
Material and Labour for Concealed point wiring with FRLS PVC insulated unsheathed, stranded copper conductor cable single core 1.5 Sqmm for one light point controlled by one one way switch incl one PVC insulated, unsheathed Single core stranded/solid copper conductor cable of size 1.5 Sqmm for continues earth wire .drawn in and including PVC conduit pipe heavy duty 20/25 mm dia complete with all accessories including sheet metal MS box of suitable size of 1.2mm thick or PVC rectangular switch board of suitable size incl 3.0 mm thick laminated sheet cover and fixed with brass screws, cap washers etc to be fixed flushed on wall including white washing/colour washing/distembering to match the disturbed surfaces complete all as specified and directed by Engr -in Charge.
All as per Sl item No 02 above but for one fan point controlled by one switch
All as per Sl item No 02 but one light point controlled by two 2 way switches, with cables 1.5 sqmm size
All as per Sl item No 02 above but for call bell/buzer controlled by one bell push.
All as per Sl item No 02 above but for one 3/5 pin multi purpose 5/6 Amps socket outlet independent.
All as per Sl item No 02 above but for one 15 Amps switch socket outlet independent but using PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm and 4.0 sqmm for earth continuity conductor for one 3 pin 15/16 Amps switch socket outlet independent complete all as specified and directed.
Supply and fixing switch piano flush type, single pole, one way, 5 amps 230 volts complete all as specified & directed.
All as per srl item No 08 but 2 way, 5Amps, 230 volt.
Supply and fixing bell push, flush type 5 Amps.
Supply and fixing stepped type electronic fan regulator, flush type on the existing phenolic laminated sheet etc. complete all as specified and directed.
Supply and fixing Switch socket combination 5 Amps 2 to 3 pin flush type, universal complete all as specified and directed.
Supply and fixing Switch socket combination 2 in 1, 5/15 Amps 3 pin flush type, universal complete all as specified and directed.
Supply and fixing Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified and directed.
S & F LED Light fitting 1x 18W, 220 V AC with driver holder including LED tube light connecting up 3 core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F light fitting mirror type with high output diffuser 2 feet 10 watt, 220 volt AC, decorative type with driver holder and LED lamp including connecting up with flexible 3 core copper cable of suitable size complete all as specified and directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & fixing energy efficient decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9W LED lamp B22 base having 100lm/W efficacy complete all as specified. Make:- Havells cat part No LHFOAJE1TZ1I060 or equivalent make of Bajaj/ Crompton/ Philips/ Surya/ Wipro.
Supply & Fixing High efficiency light emitting diode lamp with B22 Base Cap in built electronic driver with housing for heat dissipation, input voltage 220-240V AC, 50HZ output power 10/8W cool Daylight (CCT-6500K). Make:- Havells cat part No- LHLDERUEML8X010 or equivalent make of Bajaj /HPL/Surya.
Supply and fixing including connection of call Bell AC 230 Volt, single pole of Multi musicType.
Taking down of old unserviceable MCB SPN/TPN DB any type & any size complete all as specified and directed.
Supply and fixing of MCB TPN DB 4 way made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door.
Supply and fixing of MCB SPN DB 12 way made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door.
Supply and fixing of MCB SPN DB 8 way made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door.
Supply and fixing of MCB SPN DB 2 way made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 230 Volts with Double door.
Supply and fixing Sheet metal enclosures with socket plug top and MCBs single pole and neutral with 2 pin and earth plug and socket complete with one MCB 20A.
Supply fixing, connection and testing MCB TPN 240 Volts, 'C' series, breaking capacity 10 kA of rating 40 to 100 Amps.
Supply fixing, connection and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 kA of rating 32 Amps.
Supply and fixing 240V, 10 kA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amps, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
Taking down old unserviceable submain/circuit wiring any type & any size.
M & L Submain wiring with two single core multistranded copper cable of 2 x 6.0 Sqmm & one solid copper cable of 6.0 Sq.mm for contineuous earth wire both PVC insulated & un-sheathed drawn through and including heavy duty PVC Conduit of size 20/25 mm dia complete with all accessories to be fixed on wall respectively including white washing/colour washing/ distempering to match the disturbed surfaces complete all as specified and directed.
All as per srl item No 31 but of size 2 x 4.0 sqmm + 1x 4.0 sqmm.
Taking down Water heater (Geyser) and refixing of the same after complete re-wiring of building complete all as specified and directed by Engineer-in-charge.
Taking down existing Ceiling Fan/ Exhaust Fan and refixing of the same after complete re-wiring of building all as directed by Engineer-in-charge.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised earth lead wire 4.0mm , by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 32mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh,charcoal or coke and common salt in alternative layer of 15 Cm (compactedd thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. complete all as specified and directed by Engr-in-Charge.
Earth continuity conductor or main earthing lead fixed to wall on butten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or many other indirected situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed by Engr-in-Charge.
Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sq. mm , 3.5 core complete all as specified and directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft/ loose soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all specified and directed.
Removing of excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and directed.
M&L for sand cushioning with coarse sand in trenches for protection of underground electric cable, spread to uniform 23cm thickness and punned down gently to 18cm after laying the cable in trenches all as specified & directed. Note :- Compacted thickness shall be measured and paid) .
Supply and laying well burnt sub class 'B' old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
M/s Dhruv Enterprises
M/S Vimal Enterprise
M/S. SUBHAS CONSTRUCTION CO.
M/s Ravi Enterprise
M/S TRADE CENTRE
FRIENDS ENTERPRISE
M/s Capital Traders
M/S B.H. ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .