Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹41.3 L+₹3.1 L (8.05%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹41.6 L+₹3.4 L (8.82%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹45.0 L+₹6.8 L (17.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹46.2 L+₹8.0 L (20.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
9 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) HASIMARA
GE (AF) HASIMARA PO HASIMARA DIST ALIPURDUAR PIN 735215 (WB)
REPAIR/MAINT OF SIDE KERB STONE, EDGING OF ROAD, SHOULDERS, DRAINS AND ALLIED ITEMS AT VARIOUS LOCATIONS, REPAIR/MAINT OF VARIOUS E/M INSTALLATIONS IN TECH AND DOMESTIC AREA AND REPAIR/MAINT AND RESTRINGING OVER HEAD LINE INCLUDING REPLACEMENT
2023_MES_589604_1
C/8660/23-24/E8
Open Tender
Civil Works
Item Rate
210 days
GE(AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) HASIMARA
₹80,000
Yes
15 May 2023
15 Apr 2023
13 May 2023
15 Apr 2023
9 May 2023
29 Apr 2023
Amount
Demolition of brickwork or stone/boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate) as in foundation, complete all as specified and directed.
M&L for Brickwork with subclass‘B’ bricks, straight orcurved on plan exc 6m mean radius built in CM (1:4 ), complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate , in lintels upto 1.5m clearspan, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles andthroating, complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains , complete all as specified and directed.
M&L for rendering in CM (1:4 )15mm thick on brick masonry finished even and fair without using extra cement , complete all as specified and directed.
M&L for extra for forming fair finished drain or channel 45cm inner girth in cement concrete using extra cement including form moulds mitred/stopped ends etc , complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and 1.5 m deep for foundation, etc in soft/loose soil and getting out , complete all as specified and directed.
Surface dressing not exceeding 15cm deep in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick for soft/ loose soil complete all specified.
Removing excavated meterial exc 250 m and n exc 500m depositing where directed at a level n exc 1.5 m above starting point in soft/ loose soil , complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m , complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for like MH cover, bdrain pipe bed, hard standing etc, complete all as specified and directed.
M&L for precast cement concrete (1:2.4) Type B1, (Using 20mm graded crushed stone aggregate) in cover slabs , complete all as specified and directed.
M & L for mild steel TMT bars 10 mm or above dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls, etc. Including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete (Size of 450x450x100 mm) in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required , complete all as specified and directed.
M & L for broken stone or boulders hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface , complete all as specified and directed.
M&L for sand filling 50 mm thick under interlocking paver block including watering and consolidation , complete all as specified and directed.
M&L for 75mm thick plain cement concrete (1:3:6) type C-2, (using 40mm graded crushed stone aggregate), complete all as specified and directed.
M&L machine pressed pre cast concrete interlocking paver (with grey cement and pigment) any shape with PU coating of finishing and size confirming to IS-15658-2006 of 60 mm thickness M-40 grade, complete all as specified and directed.
MO&L for chequered cement concrete tiles glossy finish coloured 20 to 22 mm thick of any size and pattern as approved by GE as in patches in floor with set & jointed in neat cement slurry and pointed in coloured cement to match the tiles taid over and including cement screed 15mm thick in cement mortar (1:6), complete all as specified and directed.
M&L for flush pointing to old brick work laid on edge in CM (1:4) including racking out joints in floors, surface channels complete all as specified and directed.
Material and labour for flush pointing to old brick work laid flat in CM (1:4) including racking out joints in floors, surface channels complete all as specified and directed.
Dismantling bricks (laid flat or on edge) laid,bedded and pointed in cement mortar as in floors, channels, kerbs aprons,etc (each layer) , complete all as specified and directed.
M&L for subclass 'B' bricks, laid flat in floors with old size brick locally available best quality bricks added and jointed, in CM (1:6) and pointed in CM (1:6) complete all as specified and directed.
All as per item no 26 here-in-before but except bricks. Note old serviceable bricks obtained from item no 25 shall be re used, complete all as specified and directed..
M&L for subclass 'B' bricks, laid on edge in floors with old size brick locally available best quality bricks, bedded and jointed in CM (1:6) and pointed in CM (1:), complete all as specified and directed..
All as per item no 28 here-in-before but except bricks. Note:- Old serviceable bricks obtained from item no 25 shall be re used , complete all as specified and directed..
Supply, fabricating, installation, testing and commissioning of back-lit signage including embedding the signage baord firmly with the wall/ MS Angle frame/as per approved Art work and nomenclature as given below complete all as specified and directed:- Box with frame :- 25 x 25 mm square pipe (18 G) frame with cross supports @ spacing not exceeding 1.0 m on the box length including 20 mm x 20 mm MS Square pipe (18 G) stifferenrs duly white enamel painted in 2 coats over a coat of zinc oxide iron primer, depth of box should not be less than 165 mm, Side, Top, Back and bottom Panels :- Made out of 24 gauge chemically treated GI Sheets duly precoated / powder coated with white MATT finish coating on both inner and outer surface. Top panel to have 24 guage precoated drip cap (fixed with pop rivet or machine moulded to shape) of 25 mm on front and side to prevent damages due to rain etc. The bottom panel should be provided with access door fixed with ss screws and suitable housing for LED drivers. LED Module :- LED 12V Module beam angle >=150 degrees with IP rating >= 64, 0.72 W/70 Lumens per module of 3 LEDs with 7000 to 8000 K colour temperature, Make : Tridonic / Osram / Cree / GE LED configuration :- 29 LED Modules per Sq mt (Equal division on spacing based on height of box) and one module every 0.20 m on running length of box. LED power supply :- Input 230 V AC, power supply should be CPCC (Constant power constant current) of 30W/60W/120 W each. Graphics :- Graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation
Anti climbing devices; comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered , complete all as specified and directed.
Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole including nut, bolt, washer and painting with approved colour , complete all as specified and directed.
M&L for sand filling for protection of underground cable in duct, consolidated and compacted with clean dry sand all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out bedded portion and making good disturbed ground concrete, brick work, masonry, etc , complete all as specified and directed.
Dismantling structural steel work including doors, gates, but excluding framed truss etc, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu.m and getting out returning, filling in and ramming earth or broken rubble mixed with earth around in layers n. exc 25cm in soft/ loose soil,complete all as specified and directed.
M&L PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in and filling and mass concrete for encasing of fencing posts , complete all as specified and directed.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 , complete all as specified and directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be pre ared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing , complete all as specified and directed.
S&F steel wire fabric of weight n exc 4 kg/Sqm complete to wood or steel members , complete all as specified and directed.
S&F MS screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nuts, length of bolt n.exc 5 cm long dia of neck 11 to 15 mm , complete all as specified and directed.
Preparing new steel surfaces of any description over n.exc 10cm in width or girth and applying 2 coats of synthetic enamel paint (1st grade quality)over red oxide zinc chrome primer , complete all as specified and directed.
Preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamelled paint (1st grade quality) over a coat of Red oxide primer zinc crane , complete all as specified and directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2, (using 40 mm graded crushed stone aggregate) for base of path/ hard standing , complete all as specified and directed..
M&L PCC (1:2:4) type B-1 (using 20mm graded crushed stone agreegate) as in coping / benching /foundation etc, complete all as specified and directed.
M & L for hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface , complete all as specified and directed.
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 25 x 4 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of char coal dust and common salt complete all as shown in electrical plate No 5 and connected to earthing test point all as specified and indicated including testing on completion and marking of description of earthing on GI plate grouted on the earth chamber , complete all as specified and directed.
S&F in repair 32x6 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed.
M & L for taking down existing broken earth pit and M & L for new earthing pit in PCC (1:3:6) type C1 pre-cast RCC cover slab of size 300 x 300 x 50mm with one handle made out of 8mm dia round bar, 20mm dia GI pipe of light grade for watering funnels, wire mesh three coats of white wash on plastered surfaces (exposed surfaces) , complete all as specified and directed.
S&F porcelain vitreous white/brown/green spacers insulator of size not less than 70mmx35mmx40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50 mm long including washers and drilling holes for holding /foxomg aluminium strip/roof conductor as required including taking down the broken insulator, complete all as specified and directed.
Restringing and tightening of ACSR conductor of any size and type maintaining stranded sag including providing aluminium binding wire, jumpers on HT/LT over head lines with jumper clip complete all as specified and directed. Note:- 1. Actual number of conductor and shortest distance between the poles will be measured and paid. No extra payment will be made to the Contractor for sag and jumper etc. However burnt /damaged jumpers will be replaced by the contractor of appropriate size without any extra cost. Note:- 2. Pole to pole shortest distance including all conductor and earth wire will be measured and paid. No extra payment will be made to the Contractor for sag and jumper etc. However burnt /damaged jumpers will be replaced by the contractor of appropriate size without any extra cost.
Labour for trimming of tree branches up to 40mm thickness along the alignment of LT/HT over head electric line which are touching or falling on ACSR conductor/ plkes or near by sub stns etc at any at any height from GL and making sufficient clearance (1.5m) from conductor and taking down the same on the ground carefully avaoiding the damage of and removing to a distance where directed . Note :(i) Trimming of the branches/twigs on both sides of the conductor. (ii) Actual lenght of cutting will be measured. (iii) The distance as mentioned above will be maintained during contract currency period & same location can be measured twice in the currency of contract subject to atleast 3 months period between two triming/loaping.
M & L for cleaning of area around transformer, LT Panel, Bus Bar, VCB, RMUs, LT / HT Structure, pole, path of electrical Sub Staion / DG Set by scraping the grass by root and criperies complete all as specified and directed. Note : The cleaning of E/M Installation will be carried out during contract currency period & same location can be measured twice in the currency of contract subject to atleast 3 months period in between.
S&F jumper wire spiral type insulated aluminium conductor 50 Sqmm suitable for low/ high tension jumper wire with colour coding (Red,yellow,blue and black) complete all as specified and directed.
S&F porcelain viereous white or brown shackle type insulator including galalvanaized mild steel straps, washers, insulator bolts, washers and nuts 550 volts grade 50mm height 65mm dia and 9mm dia bolt size, complete all as specified and directed.
S&F pin type porcelain vitreous, white or brown insulator including one galvanized mild steel spoindle, two galvanized iron washers and one galvanaized iron nut, 50mm beight 65mm dia for 550 Volts grade.
Supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified.
Ditto but 2.5 mm thick for voltage upto 11 Kv (size 2x1m)
Ditto but 3.0 mm thick for voltage upto 33 Kv (size 2x1m)
M & L for power cable route marker pre-cast RCC of size 1500mm x 300mm x 50 mm with top curved portion, 8 mm dia round bar reinforcement, emboshing of letter (MES-POWER CABLE) both faces of pre-cast during casting of RCC pre-cast, applying two coats of external emulsion paint with primer approved colour and painting of emboshed surface with black colour complete all as specified and directed.
Taking down serviceable steel pole from root carefully, transporting to other places as directed and fixing of serviceable steel pole size (9 Mtr) complete with street light bracket and street light including excavation/earth work, disposal of surplus soil, PCC(1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in foundation, PCC(1:2:4) Type B-1 , using 20mm graded stone aggregate as in coping complete all as specified and directed.
M&L for cross arms,bracing,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending col or hot,drilling holes for bolts,in any shape or size as indicated or directed complete all as specified and directed.
Material and labour galvanaized steel wire 3.15 or 4 mm dia in replacement of guard/earth wire on LT OH line, re-stringing, binding and clamping etc complete all as specified and directed..
Material & labour for providing in replacement of hexagonal/rectangular guard cradles fabricated with galvanized steel wire 3.15/4mm dia all as directed by Engineer-in-Charge
Material and labour for ACSR conductor of any size in replacement all as directed on LT OH line including stringing tightening clamping and binding with insulatorscomplete all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.
All as per item No 67 above but HT, 25x20cm size complete all as specified and directed. Note :- An amount of Rs.61570.00 on account of credit schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S. JOGINDER KUMAR GOYAL
BHARAT ELECTRIC
M/S. NARENDRA KUMAR GARG
M/S BISHAL ENTERPRISES
Shri T P ANIL KUMAR
M/S BIJAY KUMAR SHIVA
M/S SARDAR MAL NAHATA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .