Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.0 L+₹5.1 L (25.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹25.2 L+₹5.3 L (26.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹25.5 L+₹5.6 L (28.0%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹27.2 L+₹7.3 L (36.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
6 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE HISAR
GE HISAR
CA NO GE(H)-74/2022-23 WELCOME MAINT TO OFFRS MD ACCN UNDER AGE B/R-II OF GE HISAR AT HISAR MIL STN
2023_MES_585292_1
CA NO GE(H)-74/2022-23
Open Tender
Civil Works
Item Rate
270 days
HISAR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE HISAR
₹80,000
Yes
15 May 2023
10 Mar 2023
8 Apr 2023
10 Mar 2023
6 Apr 2023
24 Mar 2023
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer and applying 2mm thick wall care putty all as specified & as directed.
Material and labour preparation of newly plastered/asbestos cement surfaces of ceilings & applying three coats of white wash complete all as specified.
Material and labour preparation of newly plastered surface of walls & applying three coats of white wash complete all as specified.
M&L for complete removal of existing treatment on walls (any numbers of layers) by scrapping with steel wire brushing or any other means, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots. etc and including filling cracks or holes with white cement putty and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of 1mm thick wall care putty all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of ceilings including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of white wash complete all as specified & as directed.
M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying one coat of oil emulsion distemper (OBD) of approved shade/tint including filling of crack and small hole with wall care putty all as specified & as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint of approved tint all as specified & as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises
M&L for non skid ceramic jointfree tiles (coloured) premium quality, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for vitrified ceramic tiles premium quality, 10mm thick (square/rectangular), polished, coloured (light shade as approved), area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and directed.
M&L for glazed ceramic designer & pattern (dark & light shade) jointfree tiles (coloured) premium quality, 450mm x 300mm x 7mm thick, on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
Supply and fixing in repairs Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.specified.
S&F in repairs/replacement 3mm thick acrylic transparent sheet, in square/rectangular not exc 0.5 sqm in each pane fixed / lock with window frame by using PVC snap beading with necessary self tapping reviting / screwing and suitable method with and including hacking out old broken glass (any thickness, size, quality or description) from any type of window / door glazed with putty or fixed with beads complete all as specified and directed.
S&F in repairs 40mm dia brass polished cupboard knobs fixed with nut, screws and washer complete all as specified and as directed.
Taking down shutters of any description, exc 1 sqm and n.exc 2sqm each and removal from site etc complete all as specified and directed.
Dismantling wooden boarding, any description, fixed in any position with nails all as directed.
S&F 18/19mm thick Block boards, grade 2 quality, interior grade, decorative type with decorative face veneer on one face fixed with screws to timber or iron frame work including suitable size PVC fillets to cover the front edge of board and suitable size of wooden cleats fixed as in cupboard shelves complete all as specified and as directed.
S & F factory made 30mm thick flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed.
Supply and fixing factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified & directed.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified and directed.
S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified
Supply & fixing butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 200mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified.
S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified.
M&L for rough cast finish plaster by applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12 mm depending on the texture required) mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even complete .
Material and labour preparation of newly rough cast plastered surface of walls & applying two coats of white wash complete all as specified.
S&F in repairs 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs 20 mm bore steel water GI tube medium grade with all fittings / connections & MS clamps / clips and necessary screwing as required complete and fixed with or without concealed to walls, ceilings or laid in floors complete all as specified and directed
S&F in repairs 15mm bore, fancy type brass CP Hand Shower (Health Faucet) (ABS Body) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet (Padestal pattern) White, with 'P' or 'S' trap including plastic water closet seat cover, black, closed pattern with flat bottom with mild steel chromium plated or aluminium hinging device and fixing with all joints including connection to drain or outgoing pipe and to flushing pipe, anti-syphonage pipe etc complete all as specified and as directed.
M&L for treatment of sunken floor slab compraises of the following specifications including demolition of floor and all as specified :-(i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical surfaces upto finished floor level) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and providing 40mm thick avgerage PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for providing spout 50mm bore GI pipe medium grade of length 0.50m and fixed all as specified. (ii) M&L for providing rendering of uneven surfaces of vertical sunken with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. (iii) M&L for applying two coats of polymer modified cementious water proof coating (Sika / Fosroc / STP / Asian Paint )as per manufacturers instruction to bottom and vertical sides up to finished floor level and 100mm aove FFL , the thickness of two layer shall be 1mm and when the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. (iv) M&L for providing plaster to the bottom and sides up to FFL with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spou Note :-(i) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty. (iii) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. (iii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint and cost is deemed shall be included in quoted rates. (iv) Cost of WPC shall deemed to be included in quoted rates. (v) Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage to the entire satisfaction of GE. Test shall be done in presence of reps of Engineer-in-charge and record for each sunken slab shall be maintained. (vi) The treatment shall be carried out in presence of Engineer-in-charge and tested. Cost of testing is inclued in the rates quoted above. (vii) For Payment purpose, the Plan area of Sunken floor shall be taken into account.
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
All as per item No 38.00 (here-in-before) but excluding existing concealed conduit.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit of dia not lesss than 20mm dia or suitable size medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type modular pressed steel box covered with modular cover plate and frame for housing switch, socket , fan regulators etc complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).
All as per item No 40.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 40.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 40.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 40.00 (here-in-before) but for one bell/buzzer point controlled by one bell push
All as per serial item No. 40.00 (here-in-before) but for One Light point controlled by two, two way switches with cables 1.5sqm size.
All as per srl item No. 40.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
M & L for point wiring for one light controlled by one switch with 1.5 Sqmm (nominal area) PVC insulated, unsheathed multi strand copper conductor cable FRLS drawn through existing rigid PVC coduit and conduit accessories in existing concealed type in walls/ceilings and including change of sunk type modular pressed steel box covered with modular cover plate and frame for housing switch, socket , fan regulators etc for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated unsheathed 1.5 Sqmm copper conductor cable FRLS connected to common earth dolly complete complete all as specified and directed by Engineer-in-charge. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' )
All as per item No 47.00 (here-in-before) but ceiling fan /exhaust fan point controlled by one Number one way switch.
All as per item No. 47.00 (here-in-before) but for one 5 Amp socket outlet on independent board controlled by one Number one way switch on independent board.
All as per item No. 47.00 (here-in-before) but for one 5 Amp socket outlet on the same board controlled by one Number one way switch on same board.
All as per serial item No. 47.00 (here-in-before) but for One Light point controlled by two, two way switches.
All as per serial item No. 47.00 (here-in-before) but for One Light point controlled by two, two way switches.
All as per srl item No. 47.00 (here-in-before) but for 15 Amp socket out let by using 2.50 Sqmm PVC insulated unsheathed copper conductor cable FRLS multi stranded on independent board including provn of 2.50 Sqmm unsheathed, multistranded copper conductor cable FRLS continues as earth wire connected to earth dolly etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts.
Supply and fixing in repairs modular type socket 6Amp - 5 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 6 pin combined 2 modle 230 volts AC complete all as specified and directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts all as specified & directed.
S&F switch piano flush type, single pole, one way, 15 Amp, 230 Volts.
S&F flush type socket outlet multipurpose 3 Pin 5/6 Amp (with 2 pin outlet also) 230 volts AC complete all as specified and directed.
S&F flush type socket outlet multipurpose 3 Pin 15/16 Amp (with 3 pin 5/6 Amp outlet also) 230 volts AC complete all as specified and directed.
S&F lamp holder, insluated body, with back plate suitable for batten fittings & complete all as specified & directed
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed.
S&F bell push flush type, 5 Amp 240 Volts.
S&F Bell ding dong type, AC, 230 Volts, single pole.
S & F sheet metal enclosure, double door type, having door earthing, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 Volts. Make :- Legrand / L&T / Havells / C&S.
S&F sheet metal enclosure distribution board SP&N, 12 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S.
S&F sheet metal enclosure distribution board TP&N, 4 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed. Make :- Legrand / L&T / Havells / C&S.
S & F MCB SP, 6 to 32 Amps 240 Volts , 'C' curve, 10 KA, IS-8828 marked for fixing in DB complete all as specified & directed. . Note :-Make of MCB shall be same of that DB
S & F MCB SPN, 32 Amps 240 Volts , 'C' curve, 10 KA, complete. Note :-Make of MCB shall be same of that DB.
S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.
S&F Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 6 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 6 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- Two lengths of 6 Sqmm cable, one length of 6 Sqmm cable and one length of PVC conduit will be measured as one length.
All as per item No 76.00 (here-in-before) but cable drwan through existing surfaces/concealed conduit including taking out existing unserviceable sub main wiring.
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of two module deep sunk in wall including making good distrubed surfaces complete all as specified and directed
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 3 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 4 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 6 module deep sunk in wall including making good distrubed surfaces complete all as specified and directed
S&F in repairs modular metal flush box alongwith modular white cover plate with frame for mounting, switches, sockets, fan regulator etc of 8module deep sunk in wall including making good distrubed surfaces complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 6Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 1 way 16Amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type switch 2 way 6amp, 230Volts 1 modle complete all as specified and directed
Supply and fixing in repairs modular type bell push , 5 Amp 240 Volts
Supply and fixing in repairs modular type socket 6Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
Supply and fixing in repairs modular type socket 6Amp/16 Amp - 2/3 pin combined 2 modle 230 volts AC complete all as specified and directed
S&F modular type Ceiling fan regulator electronic step type of suitable wattage, 230V suitable for 1200/1400 mm ceiling fan etc complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore upto 7.50 metre long GI pipe light grade for earth wire protection fixed with poles/wall with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down existing u/s earthing all as specified & as directed. Note :- PCC chamber shall be constructed at least 1.5m away from the earth electrode and pipe for watering shall be provided in slanting manners.
Supply and fixing LED lights fitting 1x 20/22W, 220V,AC wall mounted LED batten with polycarbonate housing & integrated electronic driver with efficacy of 100lumen/W connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. Make :- Havells / Wipro / Philips / Crompton.
S&F LED light fitting mirror type with high out put diffuser, 2 Feet, 10 Watt Cap, 220 V AC, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. Make : Cat Part No LTTB2F10WLEDEW BATTEN of C&S equivalent of makes as mentioned in Appx 'C' list of makes.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
S&F sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with and including one 20 Amp SPN MCB 'C' curve complete all as specified. Make :- Legrand / L&T / Havells / C&S.
Supply and fixing in repairs decorative wall light, stainless steel rust free fixture with white glass diffuser including 7.5w LED filament lamp complete all as specified and directed. Make : Havells Cat Part No LHFOAJD1TJ1TZ1I060of Havells or equivalent of makes
Supply and fixing in repairs round / square surface mounting 12watt LED panel in PDC housing and high translucent frosted plastic diffuser with 100lm/ w efficiency complete all as specified and directed. Make : Havells - EDGESURFACERDDLR12WLED 8575 & Crompton - LC DSP LN-R12CDL & WIPRO LDD6151XXX-57MG1
M/S D.N Choudhary
M/S KAVITA CONSTRUCTION
Shiva Constructin Co.
M/s Rao Constructions, 1173 Urban Estate-II, Hisar
NAVIN KUMAR
SHRI HARI BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .