Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 CrAccepted-AOC PLOT NO 3 YOGANAND CO OP HOUSING SOCIETY BEHIND BIJAN HOSPITAL NEAR MALPANNI HOSPITAL VIGHA MALA CANADA CORNER COLLEGE ROAD NASHIK | NASHIK | NASHIK | MAHARASHTRA | ₹16.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹16.4 CrRejected-Finance 6 KAILAS ARCADE CIDCO TOWN CENTRE CHHATRAPATI SAMBHAJINAGAR 431003 | AURANGABAD | MAHARASHTRA | 431003 | ₹16.4 Cr | L2 | Rejected-Finance Higher than L1 |
| 3 | L3₹16.7 CrRejected-Finance | ₹16.7 Cr | L3 | Rejected-Finance Higher than L1 |
| 4 | L4₹18.0 CrRejected-Finance DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | ₹18.0 Cr | L4 | Rejected-Finance Higher than L1 |
| 5 | L5₹21.4 CrRejected-Finance | ₹21.4 Cr | L5 | Rejected-Finance Higher than L1 |
Tender Value
₹20.3 Cr
EMD Value
₹10.1 L
Closing Date
7 Sept 2020, 5:00 pmClosed
Additional CEO Z P Nasik
Additional C E O Z P Nasik Trimbak Naka GPO Road Nashik
Construction of New Administrative Building of Zilla Parishad Nashik. Taluka and Dist. Nashik. Mahrashtra State
2020_NASHI_603331_1
Z P Nashik New Building/7/2020-2021 1 st Call
Open Tender
Civil Works
730 days
Trimbak Road Nashik
As Per NIT
3 documents required · 3 mandatory
₹29,500
Online Payment
₹10.1 L
Additional CEO Z P Nasik Trimbak Naka GPO Road
30 Jan 2021
14 Aug 2020
11 Sept 2020
14 Aug 2020
7 Sept 2020
14 Aug 2020
27 Aug 2020
Amount
Labour charges for removing grass, thorney shrubs, Jungli shrub, Kubabul and alike grass along roadside making the ground clean by showel and phavaras etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.)
Empty boring for 525 to 600 millimetre diametre bored Reinforced Cement Concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
Empty boring for 725 to 1050 millimetre diametre bored Reinforced Cement Concrete cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge)
Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 550 millimetre and upto and inclusive of 750 millimetre diametre including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 750 millimetre and upto and inclusive of 900 millimetre diametre including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
Chiseling through pile shells in hard strata like boulders, soft and hard rocks Beyond 900 millimetre and upto and inclusive of 1050 millimetre diametre including removing and stacking the loose materials etc. complete and disposing of the unserviceable materials outside complete.
Providing bentonite slurry process for various diameter of piles. Spec : (As directed by Engineer in Charge)
Carrying out load test for 1.5 times the proposed safe working load on the pile in driven position above 550 millimetre and upto 650 millimetre diameter including construction of test cap, use of accessories and instruments including providing graphs as per I.S. code or Std.Specifications and dismantling the test cap after testing and cleaning the site complete.
Chipping and dressing of the Reinforced Cement Concrete piles upto 0.60 meter including cleaning reinforcement and removal of dismantled materials upto a distance of 50 meter beyond the building area etc. for providing pile caps. Spec :(As directed by Engineer in Charge.
Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 600 millimetre diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 900 millimetre diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
Providing and laying cast in situ / Ready Mix Cement Concrete M-30 for bored piles each of load capacity and as per design and of 1050 millimetre diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision of reinforcement as per detailed drawings and design approved by the Engineer-in- charge including placing with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand by tremie arrangements, compaction of concrete including chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement)
Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for Reinforced Cement Concrete pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand complete. (Excluding steel reinforcement)
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.
Providing and laying in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand.
Providing and laying Cast in situ / Ready Mix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and casting in situ cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant (pan mixer). With natural sand. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing during laying in Reinforced Cement concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand (E) Third Floor
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing Second class fly ash brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimetre diameter / two hoop iron strips 25 millimetre x 1.60 millimetre at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete.
Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (E) Third Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. (A) Lower Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimeter thick Cement mortar 1:3 with conceal, secrete (RMW), Algae proof or other alike waterproofing liquids, raking of joints upto 35 millimetre depth, filling the joints with 6 millimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete )
Providing and fixing 20 to 25 millimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 millimetre between rough shahabad and Reinforced Cement Concrete walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 millimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete)
Providing and laying Polished Tandur Stone flooring 25 millimetre to 30 millimetre thick required width in plain/ diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and laying Antiskid Ceramic tiles of approved quality of company RAK / Kajaria / Nitco / Asian or equivalent make of size 30 centimetre x 30 centimetre and confirming to Indian Standard 15622-2006 (Group-B HA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying vitrified matt finish tiles having size 590 millimeter to 605 millimeter x to 605 millimeter of 8 to 10 millimeter thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying ceramic tiles of RAK/ Kajaria / Nitco /Asian or equivalent make having size 30 centimetre X 45 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing sills of required material 20 millimetre to 25 millimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete, b) Granite (C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 millimetre thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces, (excluding the primer coat.) etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (C) First Floor
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Country teak wood Four leaf paneled shutters, 35 millimetre thick style and rail and 25 millimetre thick panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete (C) First Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete (C) First Floor
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to IS. 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (A) Lower Ground Floor
(E) Third Floor
Providing & Fixing Door Frame Made out of 12 & 18 millimetre Plywood with Mica Laminate (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Fire Door 45 millimeter 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of Tufwud make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. a) Door Frame: Supplying 'Tufwud' brand frames for Fire resistant door shutters 1st class Malaysian Hardwood Frame densified (810 kg/cum) and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 psi pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 60 millimeter spray quoted with 2 coats of intumescent paint of minimum 200 micron, with single row of Brush- Type ASTROFLAME intumescent strip of size 10 millimeter x 4 millimeter affixed in the slit of the Frame for fire and smoke sealing, etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Fire Door 45mm 1HR FRL (60/60) 3 Criteria - INTEGRITY / INSULATION/ STABILITY WOODEN DOOR - Fire Door Tested in accordance to IS: 3614 Part 2. Providing of Tufwud make 60 min Fire rated doors system duly tested for 3 criteria - Integrity, Insulation and Stability Criteria as per the IS: 3614 Part 2 and BS: 476 part 22 at National Test House, Govt of India laborator and/or with Central Building Research Institute, Govt of India undertaking with standard heating conditions as specified in IS:3614 Part II 1992 and BS: 476 part 20 & 22 1987 to achieve the required integrity, insulation and stability (i.e. to restrict the heat radiation, temperature rise on the non fire side to the maximum of 140° C above the ambient temperature on the exposed surface of the shutter. The fire doors are tested with NCBN technology ("Non Combustible by Nature"). with prior approval of concerned Superitending Engineer. b) Shutter : Providing of 65mm thick asbestos free composite - 3 criteria - fire, heat and smoke check Accoustic Door Shutter with flame guard of 120 minutes IS3614 part -II comprising of 2 x 9 millimetre Calcium Silicate boards, Chemical treated internal timber with Fire retardant chemicals in pressure impregnation vessels under 160 PSI pressure as per IS:401and kiln seasoned to moisture below 15% as per IS:1141 frame work of 100x32 millimetre with 32 millimetre thick infill of ceramic fiber (density 128Kgs/CMT), vermaculite mix faced with 6 millimetre Fire retardant High Density ply, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of In tumescent paint of minimum 200 micron, and with 1 row of Brush- Type Astroflame® intumescent strip (imported) of size 10 millimetre x4 millimetre concealed for fire and smoke sealing in the grooves in the shutter on all edges except bottom, without any external lipping. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and Fixing 30 millimetre thick " FACTORY MADE BOTH SIDE PRELAMINATED SOLID PANEL Poly Vinyl Chloride DOOR SHUTTER manufactured by M/S RAJSHRI equivalent consisting of frame made out of Mild Steel tubes of 19 guage thickness and, size 19 x 19 millimetre for styles and 15 X l5 millimetre for the top and bottom rails, Mild Steel frame shall have a coat of metel primer of approved make and manufacture. Mild Steel frame shall be covered with heat mouled Poly Vinyl Chloride 'C ' channel made from 5 millimetre (+/- 0.25) thick prelaminated sheet of density 600 kilogram per cubicmetre, of size 30 millimetre thickness 70 millimetre width out of which 50 millimetre shall be flat and 20 millimetre shall be tapered in 45 angle on either side forming stiles; and 5 millimetre thick, 95 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered in 45 on the inner side to form top and bottom rail and 115 millimetre wide Poly Vinyl Chloride sheet out of which 75 millimetre shall be fait and 20 millimetre shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride strip of 20 millimetre width is to be stuck on the bottom side of the 'c' channel prelaminated paneling of 5 millimetre (+/- 0.25) thick Poly Vinyl Chloride sheet to be fitted inside the Mild Steel frame welded / sealed to the styles and rails with 5 millimetre (+/- 0.25) x 30 mm Poly Vinyl Chloride sheet beading on either side and joined together with solvent cement adhesive etc, 10 millimetre thickness (5 millimetre (+/-0.25) x 2 Numbers ) 20 millimetre wide cross Poly Vinyl Chloride sheet as gap insert for the rail and bottom rail. Door to be fixed to frames with 3 Numbers Mild Steel powder coated but hinges of size 100 millimetre x 25 millimetre x 2 millimetre using 32 millimetre long steel screws drilled suitable to pass through both the walls of the Mild Steel tube. Other hardwares should be fixed with 19 x 6 millimetre size steel screws including fixture fasting. Complete as per direction of engineer -in -charge . (B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing welded mesh of 11 gauge wires having mesh size 50 millimetre x 25 millimetre including Mild Steel Angle frame of size 35 millimetre x 35 millimetre x 5 millimetre in position with oil painting 3 coats etc. complete (A) Lower Ground Floor
(B) Upper Ground Floor
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 millimetre minimum size, crossings of Mild Steel flats of size 18 x 5 millimetre T or E section for runner of minimum 40 x 6 millimetre size for flange, Mild Steel flat for top runner of minimum size 40 x 12 millimetre with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 millimetre max. spacing of vertical channels be 100 millimetre enclosed gate position and clear space of 150 millimetre between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (IS. 10521-1983). (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing mild Steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc. (C) First Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. (C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (B) Upper Ground Floor
Providing and fixing black kadappa stone shelves 25 millimetre thick machine polished, extending the polish upto 20 centimeter width on lowerside, rounding comers, laying in position jointing with bedding cement mortar 1:4 proportion curing etc complete. (A) Lower Ground Floor
Providing antitermite treatment around the periphery of the existing building as per Indian Standard 6313 (Part-Hi) by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Rmt and refilling the trenches etc. complete covering 2 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
Providing and fixing Galvanised Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 millimetre thickness (26 Britian Wire Gauge) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Spec. – As directed by Engineer-in-charge. (E) Third Floor
Providing and fixing mild steel grill railing 20 kilogram per squaremetre with teak wood hand rail of size 75 millimetre x 60 millimetre and sill of 75 millimetre x 25 millimetre and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anti-corrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. (C) First Floor
Providing and applying water proofing treatment using acrylic polymer modified cement based water proofing coating with fibre glass mesh mixing at the rate of powder to liquid (2:1) by weight covering 9 to 10 sqm /kg with two coat using Dr. Fixit or alike of chemicals for masonry and concrete surface by brush covering 7 years guarantee on Stamp Papers etc. complete.
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 millimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1 kilogram per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 millimetre thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. (B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and making ISI Mark ferrule connection of 32 millimetre diametre to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Chromium Plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc. complete as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing screw down 15 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
Providing and fixing Orissa type white glazed earthenware 575 millimetre water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and Fixing half turn 25 millimetre diametre gun metal flushing cock including all accessories etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing white Opal series European type wall-hung, of size 400 millimetre x 370 millimetre x 575 millimetre with approved make flush valve including soil pipe, vent pipe upto outside face of wall, 100 millimetre diametre Cast Iron plug bend inlet pipe all fittings, cutting & making good walls, floors etc as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing white glazed urinal of size 710 X 460 X 300 millimetre with sensotronic concealed type flushing valve for urinal with complete kit having fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 millimetre diameter Poly Vinyl Chloride flush pipe with fitting and flushing arrangement including lead soil pipe, lead trap and soil pipe connection upto the outside face of wall etc complete. (B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Hand shower (health faucet) with 8 millimetre diametre 1metre long flexible tube having wall hook with approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 millimetre size with pillar cock, Chromium Plated Angular stop cock, long thread of approved make continental including Stainless Steel bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 millimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete. (A) Lower Ground Floor
(B) Upper Ground Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and laying for 150 millimetre diametre salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with Reinforced Cement Concrete Cover.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover.
Providing and fixing 40 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (E) Third Floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete . Both side polish (A) Lower Ground Floor
(B) First Floor
(C) First Floor
(D) Second Floor
(E) Third Floor
Providing and fixing H.D.P container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (E) Third Floor
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.
Providing and fixing heavy duty inter locking concrete RUBBER MOULD GLOSSY PAVING BLOCKS of 60 millimeter thickness of having a strength of 400 Kilogram per Squaremetre of approved quality and shape on a bed of crushed sand of 25 to 30 millimeter thick including striking joints and cleaning etc. complete, (using 100% crushed sand)
Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and fixing reinforced cement concrete cover of size 90 centimetre X 45 centimetre with frame over inspection chamber etc. complete. Heavy duty (225 kilogram)
Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10cm. height letter, figures including painting the lefters / figures with approved colour and shade complete.
Providing and fixing 45 centimetre wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to IS.-4985 including making joints with solvent cement etc. complete (E) Third Floor
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
Conveying materials obtained from road cutting including all lifts, laying in layers of 20 centimetre to 30 centimetre breaking clods, dressing to the required lines, curves, grades and section, watering and compacting to not less than 97% of standard Proctor density for a lead of over 50metre to 300metre inclusive from the site of excavation to the site of deposition as directed.
Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per IS:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete. (A) Making Bore in all types of Strata
(B) Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
(C) Checking Capacity by Flushing test
Supplying and erecting submersible pumpset of required HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell, 3 H.P. (2 Stage) suitable for 200 to 500 LPM discharge at 21 to 11 m head & (max efficiency at 19 m head & 300 Ipm) discharge & delievery pipeline 80 mm dia a necessary H. type clamp. As per specification No. WP-SMP
Supplying and erecting flat flexible 3 core 2.5 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting D.O.L. Starter400V. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 H.P. (Similar to L & T make MK-1 DOL Model)
GARDEN SOIL : Supplying on site garden soil well sieved 90% to pass through I.S.sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red.The soil will be measured by measuring box. (Farma). Item includes royalty charges. Transporting loading & unloading etc. (lead charges per 20 k.m considered)
Preparing Instant Lawn: - Excavating the ground to a required depth of 20cms, removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil / silt & manure in excavated area in 3:1 proportion to a height of 20cms. Mixing garden soil and manure thoroughly well, leveling, with required slope light watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete.
Planting small & medium size ornamental / Flowering Plants - Digging pit with size 0.6 m x 0.6 m x 0.6 m removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & Farm Yard manure upto a height of 0.60 Metre in 3:1 proportion. Mixing soil and manure thoroughly well, levelling, watering previous night, planting one to two year old healthy plant saplings as per specifications. Maintaining till well established by watering, stirring of soil and manure, replacing of casualties etc. complete.
Planting large flowering/Shady trees. (Height to 2 Mtr.)- Digging pit with size 0.9 m x 0.9 m x 0.9 m removing and conveying unwanted stuff to a required distance as directed Filling the pit with approval excavated material uplo a height of 0.30 m. and remaining height of 0.60 m. with fresh garden soil and manure in 3:1 proportion. Mining soil & manure thoroughly well, levelling, as directed, watering previous night, planting two to three year old minimum 2.0 mtr.height, healthy trees sapling as per specifications. Maintaining till well established by watering, weeding, stirring of soil sinking replacing of casualties etc. complete.
Preparing flower Bed :- Excavating the ground to the required depth of 30cms, Removing and conveying unwanted stuff to a required distance as directed, Filling fresh garden. soil & manure in excavated area in 3:1 proportion to a required height of 30cms Mixing garden soil and manure thoroughly well, levelling, watering on previous night. Planting seedlings of required annuals 25 cms. apart apart as maintaining till well established by watering, weeding, stirring replacing of casualities etc. complete.
Preparing Edging or Border :- Excavating the ground to a required depth of 20 cms. in the required area, removing and conveying unwanted stuff, rubbish to the required distance as directed. Filling the excavated part with the fresh soil and manure in 3:1 proportion to a required height to 20 cms. Mixing, levelling, watering the same. Planting rooted edging/border plants at distance of 20 cms. apart watering, weeding, stirring of soil replacing casulties pruning if necessary etc complete.
Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete.
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand / V.S.I. quality Artificial Sand
Laboratory testing Charges required for material testing on the basis of testing frequency and charges fixed by Vigilance and quality control circle, Pune for the year 2017-18, as per S. E., Vigilance and quality control Circle, Pune, Letter No. 844, dtd. 30.06.2017 (A) Cement St. Consistancy, Fineness. Sp. Gravity, Setting Time, Comp. Strength, Soundness
(B) Sand Fineness Modulus
Silt Factor
(C) Steel
Tensile Strength, % Elongation, Yeild Stress, Wt. per Rmt, Bend/Rebend Test, Proof Stress
Tensile Strength, % Elongation, Yeild Stress, Wt. per Rmt, Bend/Rebend Test, Proof Stress
(D) Cr. Metal Sieve Analysis
Specific Gravity, Water Absorption, Crushing Value, Impact Value
Abrasion Value
Flakiness Value & Elongation Index
(E) Bricks Water Absorption, Comp. Strength, Efflorescence
(F) Murum Sieve Analysis
Plasticity Index
(G) Rubble Crushing Value, Comp. Strength, Water Absorption, Specific Gravity
(H) M20,25,30 Cement Concrete Comp. St. of Cube
Conc. Mix. Design
(I) Ceramic Tiles Water Absorption,Modulus of Rupture
(J) Vetrified Tiles Water Absorption,Modulus of Rupture
(K) Flooring of Natural Stones (Kota, Granite, Tandur, Rough Shahabad) Water Absorption,Specific Gravity
(L) AlluminiumSection Thickness, Mass per Rmt
(M) PVC Pipes Weight per Running Metre, Diametre of Pipe & Wall Thickness of Pipe
Royalty Charges as per Revenue and Forest Department's notification dated 11/02/2010 as Maharashtra Minor Mineral Extraction Rules, 2010 and as per insruction in general notes on SSR 2018-2019 in P.W. Sanctioned schedule of rates for year 2018-2019 for items of lime stone, lime shell, stones, rubble, stone dust, shingles, gravel, murum, kankar, ordinary clay, ordinary earth (to be used for embankment and filling), slate and shell etc. Spec. No.: As directed by Engineer-in-charge.
M/s. Nirmiti Construction
BISHAN INFRASTRUCTURE PRIVATE LIMITED
Klassic Associates
A E infra projects pvt ltd
Hirani Enterprises
Hi Tech Infra, Aurangabad
Shrinath Construction
Shubham Civil Projects Pvt. Ltd.
Spectrum Infrastructure
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid