Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.3 L+₹6.3 L (14.7%)Rejected-Finance | L2 | Rejected-Finance being high bid value rejected | |
| 3 | L3₹59.4 L+₹16.5 L (38.3%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L3 | Rejected-Finance being high bid value rejected | |
| 4 | L4₹76.4 L+₹33.4 L (77.6%)Rejected-Finance DOOR NO 6 1 JOTHI NAGAR 6TH STREET VARATHARAJAPURAM UPPLIPALAYAM PO COIMBATORE 641015 | COIMBATORE | COIMBATORE | TAMIL NADU | 641015 | L4 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
28 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8202
2022_MES_516252_1
GE/TVL/8202
Open Tender
Miscellaneous Works
Lump-sum
180 days
Vijayanarayanam
GE/TVL/8202
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹78,000
Yes
2 Jun 2022
1 Apr 2022
30 Apr 2022
1 Apr 2022
28 Apr 2022
15 Apr 2022
1 Apr 2022 - 7 Apr 2022
60 days
Amount
SCHEDULE 'A' PART-I [E/M WORKS]
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 300 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 240 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 185 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 150 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 70 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 50 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Supply, laying and testing LT UG 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 3.5 core 35 Sqmm, laid in trenches/ duct / walls/ poles etc. including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning cable etc complete all as specified and directed.
Earthing complete with GI earth plate 600mmX600mm x 6 mm thick buried directly in ground/ earth pit not less than 2.25M below ground level with top edge of the plate not less than 1.5M below ground level connected to GI earth strip 32 x 6 mm by means of bolts, nuts and washers of GI earthing strip protected by GI pipe i.e. light grade 40mm dia all as shown in electric plate No.5 of MES SSR Part I connected to earthing test point, testing complete including necessary earth pit PCC 1: 3: 6 chamber and 50mm thick PCC 1 : 2: 4 chamber cover and with 6mm dia mild steel re-enforcement of 10Cm C/L spacing both ways in lieu of CI cover refilling of soil ncluding taking down old complete Earthing system etc complete all as directed by Engineer-in-Charge. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 40 mm dia watering pipe, wire mesh, 50mm dia light grade GI protection pipe for earth plate etc., complete
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 No) OUTGOING (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA -(02 Nos) (c) MCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3. -01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. - (01 Nos) OUTGOING (a) MCCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. -(02 Nos) (b) MCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. - (02 Nos) (c) LED Indicating lamp RYB - Set of 3.-01 Nos (d) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. - (01 Nos) OUTGOING (a) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA. -(02 Nos) (b) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA. As - (02 Nos) (c) LED Indicating lamp RYB - Set of 3.-01 Nos (d) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 400 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 320 Amp, 50 Hz, 415 V with rupturing capacity 50 KA - (01 Nos) OUTGOING (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA as - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING (a) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (05 Nos) (b) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 250 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. OUTCOMING (a) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (b) MCCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (04 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - (01 Nos) OUTGOING (b) MCCB 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (d) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos (f) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING (b) MCCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (05 Nos) (c) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (d) LED Indicating lamp RYB - Set of 3.-01 Nos (e) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 160 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c) MCCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) (d) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos (f) LED Multifunction meter with CT - 01 No
Supply installation, commissioning and testing of factory made out door type LT distribution panel board cubical type floor mounted CPRI approved fabricated out door of MS sheet 3.15 mm thick with angle iron of 50mm x 50mm x 6mm frame complete with copper bus bar 4 wire 3 phase 300 Amps capacity mounted on procelain insulator suitably spaced in totally enclosed chamber of suitable size including PVC insulated and sheathed copper cable complete including powder coated painting both internally and externally with two coats of synthetic enamel grey paint over a coat of red oixide primer comprising of the following:- (Main panel) all as directed after removing the old U/S panel board. INCOMING (a) MCCB 4 Pole 200 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (01 Nos) OUTGOING (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (c) MCCB 4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 18 KA - (02 Nos) (d) MCB TPN 32 Amp, 50 Hz, 415 V with rupturing capacity 10 KA - (02 Nos) (e) LED Indicating lamp RYB - Set of 3.-01 Nos (f) LED Multifunction meter with CT - 01 No
Taking down unserviceable ACSR Conductor/ MS Channel / insulators from 9 Mtr poles of any size complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and not exc.1.5 m deep for laying of cable, pipe and for erecting of steel tubular swaged pole etc, and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as directeed.
Removing excavated material not exc 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting points in soil all as directed by Engineer-in-Charge.
Supply, spreading and compacting of riddled earth for cable cushion on both top and bottom of cable, including ramming as specified and directed by Engineer-in-Charge. (Note :- Punned thickness only will be measured)
Supply and lay burnt bricks for cable protection of sub class 'B' standard size in trenches all as specified.
Supply and laying GI tubing Light grade of size 100 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed.
PHEJAYS AGENCIES
SUPER COOL
PRIYA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .