Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹13.2 Cr
EMD Value
₹9.8 L
Closing Date
25 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER
HQ CWE HISAR
PROVN OF MES COMPLEX AT HISAR MIL STN
2025_MES_701963_1
CWE/HSR-82 OF 2024-25
Open Tender
Civil Works
Lump-sum
548 days
HISAR MIL STATION
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE WEST HISAR
₹9.8 L
26 Oct 2025
20 Mar 2025
27 Oct 2025
13 Aug 2025
25 Oct 2025
17 Oct 2025
28 Mar 2025 - 11 Apr 2025
RATE In Figures To be entered by the Bidder Rs. Ps.
Lump sum price worked out by the tenderer for BUILDING WORKS as listed in Schedule ‘A’ Part-I(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-II(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for ROAD, PATH AND CULVERT WORKS as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for AREA DRAINAGE WORKS as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for FENCING & GATE as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)
Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)
Supply and fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 5 KVA with mounting bracket complete with time delay relay.(For ACs) complete all as specified.
Lump sum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-XIII(Ref pre-priced schedule attached separately)
M&L for Acrylic Flooring Synthetic volleyball court seamless having thickness 2-6 mm with mate finish blue in colour, water resistant all as specified and as directed.
Material and labour for PVC rigid non metallic concealed conduit of size 25 mm dia medium duty, ISI marked ivory colour with all conduit fittings/fixing accessories and terminated in modular metal flush boxes including connection for wi-fi/Lan Connected items and with frame for the surface as per exisitng treatment complete all as specified and directed.
S & F of Bell Push, 230 Volt flush type single Pole complete 5 Amp complete all as specified and directed.
S & F for lamp holder including Highly efficient LED Bulbs, 9 watt insulated body with back plate suitable for batten fittings etc complete all as specified and directed.
S & F Bell Ding Dong all as specified and directed by E-in-Charge
S & F for lamp holder including Highly efficient LED Bulbs, 0 watt (Red & Green ) insulated body with back plate suitable for batten fittings etc complete all as specified and directed.
Supply and Fixing high Speed Ethernet Wall socket ABS flush Mount 85x85x36 mm complete all as specified and directed.
Supply and fixing LED light fitting 36 watt Recess/Surface Mounted type with mounting arrangement (Recess suitable for 2 x 2 Grid Hanging) sheet aluminium housing with high quality LGP and PMMA diffuser separate HPF driver suitable for Armstrong and grid ceiling LED 240 volts complete all as specified and directed.
Supply and fixing LED light Panel light Surface/Roof Mounting Round type complete 1 x 12 watt complete all as specified and directed.
Supply and Fix LED Outdoor beam light throw focus light upto 12 metre distance (warm light) complete all as specified and directed
M&L for preparing bituminus surfaces of road and making 1.5mm thick lines, dashes, arrows, letters etc. on road, pavement and the like not exc 10cm wide with hot applied Thermoplastic Road marking paint of approved colour confirming BS 3263-1989 with special applicater machine all as per manufactures instruction complete all as spd and dir.
Supply ,laying jointing,commissioning and testing Ductile iron pipe with spigot and socket end centrifugally cast (spun) class K-9 conforming to IS-8329-2000 in any length laid in trenches complete all as specified and directed of following size 100 mm bore.
Supply and fixing Sluice valve flanged of class PN 1.0 ISI marked 14846-2000 complete with stainless steel spindlle ,flanged both ends, drilled CI gate with brass ring and iron hand wheel and suitable for 100 mm sizes CI/DI pipe line complete all as specified and directed.
Supply and fixing Sluice valve flanged of class PN 1.0 ISI marked 14846-2000 complete with stainless steel spindlle ,flanged both ends, drilled CI gate with brass ring and iron hand wheel and suitable for 80 mm sizes CI/DI pipe line complete all as specified and directed.
Construction of valve pit (Size 90 cm X 90 cm X 90 cm) of double brick masonary with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed.
Construction of valve pit (Size 75 cm X 75 cm X 75 cm) of double brick masonary with internal plastering from the top of surface including cover of MS sheet 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coat of synthetic enamelled paint over a coat of red oxide and grouting to PCC 1:2:4 plastering in cement morter 1:3, foundation concrete 1:3:6 including necessary earthwork complete all as specified and directed.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine or by using manual mechanical tools with manpower for inserting pipe of size 40 mm to 100 mm bore dia for proection of LT Cables.
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 50 X 50 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated se
mense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :- (Panel A) :- (a) Air circuit breaker 4 Pole 600 amps ,415 Volt of breaking capacity not less than 50 KA with electronic/ micro processor release - 01 Nos (Incommer Supply) (b) Copper Busbar 900 Amps duly sleeve insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCCBs - 01 Set. OUTGOING (c) MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable Thermal & Magnetic Range (Optium 2.0) - 01 Nos (for Panel-B) (d) MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable Thermal setting (Optium 2.0) - 01 Nos (for Panel-D) (e) MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable Thermal setting (Optium 2.0) - 01 No (for Panel-C). (f) MCB TPN 40 AMP for Timer- 01 Nos (g) LED Indicator lamp (R,Y,B) - Set of Three. (h) Digital Ammeter 0-600A with suitable ratio of CTs – 01 No. (l) Digital Volt meter 0-500 Volts – 01 No.
NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Supply & fixing of automatic street light control switch with infrared sensor based Nature Switch & voltage monitoring system (VMS). Nature switch operation should be based on Natural Light Lux level. Required illuminance level for Switching ON is < 30 Lux and for Switching OFF > 10 Lux. The Sensor should also have pert night operation facility of min. 4 hrs. to max 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The sensor & VMS along with suitable Power Contractor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Terninate proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operaation (i.e. sensor & VMS By-Pass option) with 3nos. Contractors, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min. 10 sq.mm
Supply & fixing LT feeder pillar (Outdoor type) single door type cubical typeof Size 50cm x 50cm x 25cm made out of CRCA sheet 3.15 mm thick dust and vermin proof and angle iron size of 40 x 40 x 5mm having 200 Amp rated Al bus bar .Panel should be covered from all side with front lockable door and hinges complete and powder coated. ( 3 For office, 2 for Complaint Cell)
Supply and fixing of energy efficient LED street light fittings of 45 W capacity including electric connection, complete fitting including all accessories and following specification and all as directed by Engr-in-charge. (a) Lumen system efficacy of luminarie should be minimum 100 Lumen per watt. (b) Input voltage range 140 to 270 volts (c) Temp operating range minus 10°C to Plus 50°C (d) Power factor : minimum 0.95 (e) THD : Max 10% (f) CRI : More than 80 and CCT : 5700 K (g) IP rating : IP66 (h) IK rating : Minimum IK07 (j) Pressure die cast aluminium alloy for housing and heat resistant alear toughened glass (k) Built in potted LED driver of the make as of the luminaire. (l) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection 10 kV (inbuilt + extended) (n) Lens:- High sfficiency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing of energy efficient LED Flood Light fittings of 120 W capacity including electric connection, complete fitting including all accessories and following specification and all as directed by Engr-in-charge. (a) Lumen system efficacy of luminarie should be minimum 100 Lumen per watt. (b) Input voltage range 140 to 270 volts (c) Temp operating range minus 10°C to Plus 50°C (d) Power factor : minimum 0.95 (e) THD : Max 10% (f) CRI : More than 80 and CCT : 5700 K (g) IP rating : IP66 (h) IK rating : Minimum IK07 (j) Pressure die cast aluminium alloy for housing and heat resistant alear toughened glass (k) Built in potted LED driver of the make as of the luminaire. (l) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (m) Surge protection 10 kV (inbuilt + extended) (n) Lens:- High sfficiency wide angle lens (o) BIS approved fixtures and driver (p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
Supply and fixing junction box complete with fixing accessories and following specification and all as directed by Engr-in-charge. (a) Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material. (b) Size Min 210 mm x 155 mm x 92 mm. (c) IP protection : IP 66 in accordance with IEC 60529. (d) Internally embedded gasket of plyurethane. (e) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC-60670-2 to 5 and color according to RAL 9011. (f) The manufacture of junction box shall submit a copy of IEC cerfigicate. (g) Junction box shall be fire retardant and self extigushing in accordance with IEC-60695-2 to 11, DIN VDE 0304 part -3, UL94 V-2 flammability standard. It should be tested at Glove Wire test for 960C. (h) The degree of protection of enclosure against mechanical load shall be in accordance with E N 50298 for IK08. (j) Junction box shall be 4 pole complete with single pole MCB 'C' curve of 6 AMP, rating.
M&L Decorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watt including LED lamp complete all as specified & directed.
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box as directed by Engr- in- Charge.
Factory made unreinforced precast concrete cable covers conforming to IS:5820, class LV type 1 size 250x150x40 mm for cable protection complete all as specified.
Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size complete.
Providing cement concrete type B1 (1;2;4) (20 mm graded aggregate)in precast posts for cable route indicator of size 500x300x100 mm rounded top as directed and grouting in ground with PCC (1;3;6) block of size 350mmx150mmx200mm including 10 mm thick plastering all around of exposed surfaces of post above ground with CM (1:4) and applying two coats cement base paint on plastered surface and writing with synthetic enamel paint in black colour in suitable size like HT Cable , complete all as specified and directed by Engr-in-Charge.
M&L for Factory made unreinforced precast concrete cable covers conforming to IS:5820, class HV type 1 size 300x180x40 mm for cable protection complete all as specified
Transformer 400 KVA, 11/0.433KV, 50 Hz, step down, outdoor type, ONAN Cooled oil immersed copper wound energy efficient transformer, complete with first filling of IS-335 ISI marked filtered & dehyrated tranformer oil and other standard fittings/acceesories and 7 position OFF load circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, with provision of making connection of incomming HT cable and outgoing LT cable Busbar all as per IS 1180-2014 (Level-2) as per Latest IS and complet with and including all required accessories for installation of transformer all as specified and directed. The transformer shall comprises following: (i) 03 Nos porcelain bushings with copper rod on HV side. (ii) 04 Nos bushing on LV Side. (iii) Oil level guage,oil drain filter valve,lifting hucks,oil filling hole with cap/plug with connection plate, Air release valve plug complete. (iv) 01 Nos 150mm dia, oil temperature indicator with A&T contacts,vapour pressure type having range 0-120 degree with metal guard. (v) 01 Nos 150mm dia, winding temperature indicator with A&T contacts,vapour pressure type having range 0-120 degree with metal guard. (vi) 02 Nos earthing terminals on tank cover to facilitate fixing of 50x6mm GI earth strip for earthing of body including rating plate and terminal marking plate. All date shall me marked on Rating plate. (vii)First fill of unused and new transformer oil,IS-335 Marked filtered and tested upto 60KV die electric strngth at 2.5 mm air gap between testing electrode.
M&L for construction of plateform of size 2500 x 2500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 6 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primer complete all as specified and shown on TD drawing SKB-899.
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 40 X 40 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder c
Supply and fix air cooled split unit air conditioner inverter type BEE 5 Star rated of capacity 2 Tonne single phase 230 Volt 50 Hz AC indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building complete all as specified.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TENDERDOCUS.pdf
Tender Documents • 2.18 MB
BOQ_786259.xls
BOQ • 0.29 MB
10SchedulesSUMMERAPPL.pdf
Additional Documents • 0.02 MB
11SchedulesVBFPINCETC.pdf
Additional Documents • 0.09 MB
12SchedulesSITECLEA.pdf
Additional Documents • 0.03 MB
SchofcreditMES.pdf
Additional Documents • 0.08 MB
13SchedulesDEMWK.pdf
Additional Documents • 0.05 MB
MAKES.pdf
Additional Documents • 0.79 MB
1SchedulesBLDG.pdf
Additional Documents • 0.06 MB
2SchedulesIW.pdf
Additional Documents • 0.09 MB
3SchedulesIEle.pdf
Additional Documents • 0.14 MB
4SchedulesRDPATH.pdf
Additional Documents • 0.16 MB
5SchedulesSEWAGE.pdf
Additional Documents • 0.02 MB
6SchedulesAREADRAIN.pdf
Additional Documents • 0.01 MB
7SchedulesFENCGATE.pdf
Additional Documents • 0.22 MB
8SchedulesEWS.pdf
Additional Documents • 0.17 MB
9SchedulesEXELECTR.pdf
Additional Documents • 0.18 MB
Tenderdocument.pdf
Tender Documents • 0.05 MB
Tenderdocument_2.pdf
Tender Documents • 0.09 MB
Tenderdocument_3.pdf
Tender Documents • 0.79 MB
Tenderdocument_4.pdf
Tender Documents • 2.18 MB
Tenderdocument_5.pdf
Tender Documents • 0.03 MB
Tenderdocument_6.pdf
Tender Documents • 0.08 MB
Tenderdocument_7.pdf
Tender Documents • 0.22 MB
Tenderdocument_8.pdf
Tender Documents • 0.17 MB
Tenderdocument_9.pdf
Tender Documents • 0.18 MB
BOQ.xls
BOQ • 0.29 MB
Tenderdocument_10.pdf
Tender Documents • 0.09 MB
Tenderdocument_11.pdf
Tender Documents • 0.14 MB
Tenderdocument_12.pdf
Tender Documents • 0.06 MB
Tenderdocument_13.pdf
Tender Documents • 0.16 MB
Tenderdocument_14.pdf
Tender Documents • 0.02 MB
Tenderdocument_15.pdf
Tender Documents • 0.01 MB
Tenderdocument_16.pdf
Tender Documents • 0.02 MB
Amdt3.pdf
PDF • 0.11 MB
Amdt2.pdf
PDF • 0.11 MB
Amdt1.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .