Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tenderer | |
| 2 | L2₹42.9 L+₹2.6 L (6.34%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Being Other than Lowest Tenderer | |
| 3 | L3₹49.4 L+₹9.0 L (22.4%)Rejected-Finance | L3 | Rejected-Finance Being Other than Lowest Tenderer | |
| 4 | L4₹49.9 L+₹9.6 L (23.7%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Being Other than Lowest Tenderer | |
| 5 | L5₹51.1 L+₹10.7 L (26.6%)Rejected-Finance 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L5 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | Shree Ayyappa Engineering L4 | ASHOK ENTERPRISES L6 | Shetty Construction Co L1 | Darpan Construction L5 | Chakshu Enterprise L2 | shubham construction L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying installation, Testing & Commissioning of Microprocessor based 4 loop capacity , Networkable analogue addressable type fire alarm control panel with min 600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analogue addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required, and panels shall have provision of integration with BMS System, (UL/EN Approved) as per tender specificaiton. Panel shall be integrated with respective to the zoning of PA System so that incase of fire PA System shall automatically come in announcement mode as per tender specificaiton.
Make : Honeywell/Siemens/Bosch/Morley/Edward | 1 | Each | 4,26,000 ₹4,26,000 | 4,30,000 ₹4,30,000 | 3,35,000 ₹3,35,000 Lowest | 4,45,000 ₹4,45,000 | 3,73,500 ₹3,73,500 | 4,22,000 ₹4,22,000 |
| 2.00 | Supplying installation, Testing & Commissioning of Microprocessor based 2 loop capacity , Networkable analogue addressable type fire alarm control panel with min 600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analogue addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required, and panels shall have provision of integration with BMS System, (UL/EN Approved) as per tender specificaiton. Panel shall be integrated with respective to the zoning of PA System so that incase of fire PA System shall automatically come in announcement mode as per tender specificaiton.
Make : Honeywell/Siemens/Bosch/Morley/Edward | 1 | Each | 1,76,000 ₹1,76,000 | 1,80,000 ₹1,80,000 | 1,55,000 ₹1,55,000 Lowest | 1,82,345 ₹1,82,345 | 1,57,400 ₹1,57,400 | 1,74,000 ₹1,74,000 |
| 3.00 | Supplying installation, Testing & Commissioning of Microprocessor based single loop capacity , Networkable analogue addressable type fire alarm control panel with min.600 character LCD display, The panel should be equipped with sufficient numbers of 1 loop with up to 10 to 15% spare capacity with each loop shall have a capacity of minimum 99 detectors and 99 analog addressable devices in one loop. Four access levels, capable of taking Flash Scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs, pressurization fans, ventilation fans at fire pump room, monitoring of fire sprinkler and fire hydrant pump, 240 volts AC power supply, automatic battery charger, 24 voltsx2 nos sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. and panels shall have provision of intigraton with BMS System.(UL/EN Approved) as per tender specificaiton.Panel shall be integrated with respective to the zoning of PA System so that incase of fire so PA System shall automatically come in announcement mode as per tender specificaiton.
Make : Honeywell/Siemens/Bosch/Morley/Edward | 4 | Each | 1,16,000 ₹4,64,000 | 1,22,000 ₹4,88,000 | 1,05,000 ₹4,20,000 | 1,22,340 ₹4,89,360 | 78,150 ₹3,12,600 Lowest | 1,14,000 ₹4,56,000 |
| 4.00 | Supplying installation, Testing & Commissioning of Microprocessor based repeater networkable analogue addressable type fire alarm control panel with min 600 character LCD display, four access levels, capable of taking flash scan devices, flash EPROM sufficient numbers of programmable relay controls for controlling AHUs , pressurization fans, ventilation fans at fire pump pump room, monitoring of fire sprinkle and 240 volts AC power supply, automatic battery charger , 24 volts sealed lead acid batteries sufficient for 24 hours normal working anf then be capable of operating the system for 2 hours during an emergency condition as required and panels shall have provision of integration with BMS system(UL/EN Approved) as per tender specification. Panel shall be integrated with respective to the zoning of PA system so that incase of fire PA System shall automatically come in announcement mode complete all as specified and directed | 1 | Each | 6,500 ₹6,500 | 5,500 ₹5,500 | 49,000 ₹49,000 | 5,662 ₹5,662 | 47,250 ₹47,250 | 5,300 ₹5,300 Lowest |
| 5.00 | Supplying installation, Testing & Commissioning of Analog addressable Multi Criteria (Optical +thermal) detector with mounting based LED for AFC(Above Celling & below celling) as per tender specificaiton all as specified and directed.
Make : Honeywell/Bosch/Morley/Siemens | 440 | Each | 3,600 ₹15,84,000 | 3,800 ₹16,72,000 | 3,300 ₹14,52,000 | 3,750 ₹16,50,000 | 3,270 ₹14,38,800 Lowest | 3,600 ₹15,84,000 |
| 6.00 | Supply, Installation, testing and commissioning addressable Manual call point(Pull down/Break Glass Type). The device shall have an LED which shall blink in normal state and get steady on activation to monitor the health status of the device and shall be UL listed, semi flush type complete all as specified and directed.
Make : Honeywell/Siemens/Bosch/Morley | 50 | Each | 3,700 ₹1,85,000 | 3,800 ₹1,90,000 | 4,100 ₹2,05,000 | 3,600 ₹1,80,000 Lowest | 4,200 ₹2,10,000 | 3,650 ₹1,82,500 |
| 7.00 | Supply and fix addressable electronic sounder cum strobe with all accessories complete as specified and directed. | 50 | Each | 5,890 ₹2,94,500 | 5,900 ₹2,95,000 | 5,200 ₹2,60,000 Lowest | 5,700 ₹2,85,000 | 6,400 ₹3,20,000 | 5,900 ₹2,95,000 |
| 8.00 | Supplying installation, Testing & Commissioning of Response indicator for above celling detectors & Cabin Detectors
Make : Honeywell/Bosch/Morley/Siemens | 85 | Each | 160 ₹13,600 | 165 ₹14,025 | 160 ₹13,600 | 192 ₹16,320 | 115 ₹9,775 Lowest | 152 ₹12,920 |
| 9.00 | Supply & laying PVC FRLS armoured cable 1.5sq mm solid copper conductor 2 core, XLPE Insulated, Extruded PVC sheathed, galvanized steel strip, electric power cables (heavy duty) 1100 Volts grade, laid in duct / along pole/wall etc including making connection complete and making good the distrubed surface matching with existing surface complete all as directed. Make of wire : Polycab/ Havells/ Gloster Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Make; Polycab/ KEI/RR. | 6,000 | RM | 230 ₹13,80,000 | 222 ₹13,32,000 | 125 ₹7,50,000 Lowest | 232 ₹13,92,000 | 170 ₹10,20,000 | 222 ₹13,32,000 |
| 10.00 | Supplying installation, Testing & Commissioning of Addressable control modules for AHU, Access control Integration & stairs Pressurization Fan Hooters / Sounders / Strobes etc.as per tender specificaiton.
Make : Honeywell/Siemens/Morley/Siemens | 21 | Each | 4,000 ₹84,000 | 4,750 ₹99,750 | 4,000 ₹84,000 | 4,156 ₹87,276 | 3,975 ₹83,475 Lowest | 4,200 ₹88,200 |
Tender Value
₹47.4 L
EMD Value
₹94,782
Closing Date
1 Oct 2025, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8230 PROVISION OF AUTOMATIC FIRE DECTECTION SYSTEM IN BUILDING NO P-183 (C NO.95 PM DEPT) AND BUILDING NO. P-50 (C NO. 97 WED DEPT) AND PROVISION OF AUTOMATIC FIRE DETECTION SYSTEM IN LION GATE AND MUSTER GATE AT NAVAL DOCKYARD MUMBAI UNDER
2025_MES_730115_1
8230/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹94,782
Yes
20 Nov 2025
10 Sept 2025
3 Oct 2025
18 Sept 2025
1 Oct 2025
24 Sept 2025
10 Sept 2025 - 18 Sept 2025
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .