Executive Engineer
Public Health Engineering Division Panchkula
Supplying of PH Meter Conductivity meter TDS Meter Turbidity Meter Hot Air OVen Hytrometer Thermometer Sample
2022_HRY_206122_1
Amt. Rs. 6.02 Lacs Labortary
Open Tender
Civil Works
Works
30 days
Public Health Engineering Division Panchkula
Supplying of PH Meter Conductivity meter TDS Meter Turbidity Meter Hot Air OVen Hytrometer Thermometer Sample
2 documents required · 2 mandatory
₹1,000
Yes
₹12,040
Yes
9 Jun 2022
1 Feb 2022
7 Feb 2022
1 Feb 2022
7 Feb 2022
1 Feb 2022
Amount
pH meter (within 5years AMC) (Make Lovibond, EUTECH, WTW, OAKTON, Metrohm) Ph Range-2.00 to 16.00 pH Resolution /Accuracy 0.01 pH/± 0.01 pH ORP Range± 2000mV Resolution /Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond) 1.2 ± 0.2(± 199.9 mV)/ ± 2 mV(beyond) Temp. range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution /Accuracy 0.10 C (0.10 F)/±0.3ºC/±0.5 ºF(0 to 70 ºC ATC Yes (0 to 1000 ºC Buffer Options USA" pH 1.68, 4.01, 7.00, 10.01, 12.45 NIST pH 1.68, 4.01, 6.86, 9.18, 12.45 No. of pH Calibration Points 5 points Built-in Electrode Arm Yes Memory 100 data sets Electrode Included ECFC7252101B, single junction pH electrode. Temp. Probe Included LCD DISPLAY CUSTOM dual-display LCD (5.6x6x7.5cm) Power Requirements Included 100 /240 VAC SMPS Power Adapter with US/UK/EUR/Japan plug, 9V, 6W, CENTRE (Lovibond, EUTECH, WTW, OAKTON, Metrohm)
Conductivity meter /TDS Meter (Make Lovibond, EUTECH, OAKTON, WTW, Hach, Metrohm) Conductivity Range 0.01 to 200.0 mS/cm Resolution /Accuracy 0.01/0.1 μS ; 1/0.01mS/ 0.01 Ms Salinity Range 0.0 to 80.0 ppt Resolution /Accuracy 0.01 / 0.1 ppm ; 0.001/0.01/0.1 ppt ± 1 % full scale TDS Range 0.050 ppm to 500 ppt (@ TDS factor 1.00) Resolution /Accuracy 0.01 / 0.1 ppm ; 0.001 /0.01/ 0.1 ppt Resolution /Accuracy 0.10 C (0.10 F); ±0.3 ºC (±0.5 ºF) Temp. Coefficient Linear & amp; pure; 0.000 to 10.000% Normalization Temperature 15.0 to 30.0 ºC (59.0 to 86.0 ºF) Built-in Electrode Arm Yes Compensation ATC /MTC Memory 100 data sets electrode Included, 2 Cell epoxy body Conductivity electrode, k= 1.0, Power Requiredments Included, 100 / 240VAC SMPS Power Adapter, 9V, 6w (Lovibond, EUTECH, OAKTON, WTW, Hach, Metrohm)
Turbidity meter (Benchtop)/ (Portable) (with amc for 5 years) (Make Eutech, WTW, Hach, Oakton) Accuracy: ± 2% of reading plus 0.01 FNU/NTU from 0- 1000 FNU /NTU Certifications: CE, KC, RCM Communication: USB Compliance: ISO Data logging: 2000 total logs, includes reading log, verification log and calibration log Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (IR LED) at 860 ± 30nm Measurement method: Nephelometric Operating temperature range: 0-40ºC Power reequirements (Voltage): 100-240 VAC Range : 0-1000 NTU NTU/FNU: 0-1000 Reading modes: Single, contiuous, Rapidly Setting Turbidity, Signal averaging on or off Regulartory : Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033 Repeatability : ± 1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions) Response time: Signal averaging off: 6.8 seconds/Signal averaging on :14 Note: Smaller sample cells (less than 25 mm ) can be used when a cell adapter is used. Sample requirements : 25 mm sample cell: 20mL minium 0 to 70 ºC (32 to 158 ºF) Source Lamp: LED Stabilisation time: Immediately Storage conditions: 20 to 60ºC Units : FNU and NTU Eutech, WTW, Hach, Oakton
Distillation Plant (Make Borosil, Glassco) All Quartz Double Disillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr Borosil, Glassco
Hygrometer (Make HTC) Temp. Range -500C ˜ + 7 700C Temp. Measuring Accuracy: ± 10C Temp. Resloution: 0.10C Humidity Meas. Range: 10% RH˜ 99% Humidity Accuray : ±5% RH Humidity Resolution: 1%
Thermometer simple and with probe (Make LT (Type K) Thomassci, Hanna) Digital LCD Thermometer with Sensor Probe
Analytical Balance (With 5 years AMC) (Make Radwag, Mettler Toledo, Sartorius, Shimazhu) Analytical balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size 90 mm
Calibrated Weights (Make Radwag, Mettler Toledo, Sartorious, denver, wensar) Standard Weight Box Class F1 capacity 1mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)
Dessicator (Make Borosil, Glassco, Thermo) 250 mm along with 1kg sillia gel (Qualigen)
AC (1.5 Ton) (Make Llyod (Dual Weather) Mitsubishi pudgd fitting with stabilizer
Heating Mantle (Single Station) (Make Glassco, DAN Logitech, Thermofisher Scientific)
Water bath Purpose:It is used to incubate samples at a constant temperature over a long period of time. (Make Borosil, Glassco, Thermo Fisher Scientific) Nominal capacity-20 L, 8 holes with lid assembly, working Temperature range Ambient + 5ºC to 99 ºC, Temperature stability ± 2.0ºC, Interior dimensions (525x325x150)nnm Exterior dimensions (WxDxH) (530x326x2600) mm, Display 7 Segment LED Display Tank material SS 304, Outer body SS 304, Electrical Requirements 9 A, Power Consumption 1600 W, Calibration from NABL Lab, AMC for 5 Years.
RAJAN SCIENTIFIC TRADERS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .