| Sl No | Description | Qty | Unit | ELECTRO FIRE PROTECT ENGINEERING & CONSULTANCY L3 | TRIPTI ENTERPRISE L1 | UNIQUE FIRE PROTECTION SYSTEM L2 |
|---|---|---|---|---|---|---|
| 1.00 | Deputation of Skilled Manpower twice a month for intensive checking of all the pumps installed for fire fighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all valves and other instruments installed inside pump house and making necessary rectifications / repair /replacement to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record. (Excluding rectification and rewinding of electric motor, overhauling of Diesel Engine) 2 (Two) Nos. Pump House in the Hospital campus. | 2 | No | 65,000 ₹1,30,000 | 45,000 ₹90,000 Lowest | 60,000 ₹1,20,000 |
| 2.00 | Inspection and checking of hydrant network including pipes, sprinklers system ,hydrant riser, hose pipes, pressure gauge once in 3 months and submit report to PWD for any leakage or damage of hydrant / landing valves or any other type of valves and instruments for our further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair / rectification of all type of valves such as replacement of worn out or damaged gasket with new one, replacement of damaged bolts and nuts with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network, the vendor shall drain out water from risers and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water.
2 (Two) Nos. Pump House in the Hospital campus. | 2 | No | 64,997 ₹1,29,994 | 14,000 ₹28,000 | 10,000 ₹20,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
25 Sept 2026, 12:00 pmClosed
ASSISTANT ENGINEER
ROOM NO 16 GROUND FLOOR PURTA BHAVAN DF BLOCK SECTOR I SALT LAKE KOLKATA 700 091
Dr B C Roy PGIPS Beliaghata and Phoolbagan campus Periodical Maintenance for Fire Water Pumps and accessories inside the Pump House through comprehensive maintenance contract including inspection of hydrant network during the year 26 27
2026_WBPWD_5023092_2
WBPWD/AE/NKHSD-I/NIeQ-02/26-27
Open Tender
CIVIL WORKS
Item Rate
365 days
Dr B C Roy PGIPS
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
12 Oct 2026
9 Sept 2026
28 Sept 2026
10 Sept 2026
25 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Deputation of Skilled Manpower twice a month for intensive checking of all the pumps installed for fire fighting system including sequential operation of those pumps to check the performance of each pumps. The job includes checking of all valves and other instruments installed inside pump house and making necessary rectifications / repair /replacement to ensure proper functionality of the fire pumps. Storage of Diesel to be checked and refilling to be done whenever necessary to ensure smooth operation of Diesel Engine driven pump during emergency. Mock Test for fire pumps both in AUTO & MANUAL operations to be conducted during the visit in every 15 days and report of the test to be submitted to PWD for record. (Excluding rectification and rewinding of electric motor, overhauling of Diesel Engine) 2 (Two) Nos. Pump House in the Hospital campus. | 2 | No | - | - |
| 2 | Inspection and checking of hydrant network including pipes, sprinklers system ,hydrant riser, hose pipes, pressure gauge once in 3 months and submit report to PWD for any leakage or damage of hydrant / landing valves or any other type of valves and instruments for our further course of action to ensure proper functionality of the installed fire protection system. The scope also includes minor repair / rectification of all type of valves such as replacement of worn out or damaged gasket with new one, replacement of damaged bolts and nuts with new one etc. Major rectification such as replacement of damaged hand wheel, flanges, perforated pipes, pipe supports, valve seat rings etc. to be done on chargeable basis with prior intimation to PWD. During inspection of water network, the vendor shall drain out water from risers and recharge it with set pressure after proper flushing. Inlet valves of hydrant risers to be kept close after completion of flushing and recharging of water to avoid any accidental discharge of water.
2 (Two) Nos. Pump House in the Hospital campus. | 2 | No | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.14 MB
Tendernotice_2.pdf
PDF • 1.06 MB
BOQ_5106133.xls
BOQ • 0.28 MB
corrigendum1.pdf
PDF • 0.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .