| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.2 LAccepted-AOC 1901 MOROCCAN ROYAL PALMS AAREY COLONY GOREGAON EAST MUMBAI 400065 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | ₹73.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹85.8 L+₹12.6 L (17.3%)Rejected-Finance | ₹85.8 L+₹12.6 L (17.3%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹98.8 L+₹25.6 L (35.0%)Rejected-Finance B203 SECTOR 21 TRICITY PEARL CHS LTD PLOT 14 VILLAGE TOWN ULWE CITY NAVI MUMBAI RAIGAD MAHARASHTRA 410206 INDIA | RAIGAD | MAHARASHTRA | 410206 | ₹98.8 L+₹25.6 L (35.0%) | L3 | Rejected-Finance Not L1 |
| Sl No | Description | Qty | Unit | BACHITTAR SINGH & CO. L1 | V R Construction L2 | OLO HOUSING INFRA LLP L3 |
|---|---|---|---|---|---|---|
| 1.00Dismantling | ||||||
| 1.10 | Dismantling of existing fire hydrant MS pipeline - 3", 4", 5", 6", 8", 10" | 1,500 | Meters | 100 ₹1,50,000 Lowest | 566 ₹8,49,000 | 100 ₹1,50,000 Lowest |
| 2.00 | Supply, installation, Testing and commissioning of 10 inch size, 6 mm thickness, MS black Class C pipes as per IS: 3589 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 50 | Meters | 4,615 ₹2,30,750 Lowest | 5,000 ₹2,50,000 | 7,054 ₹3,52,700 |
| 3.00 | Supply, installation, Testing and commissioning of 8 inch size, 6 mm thickness, MS black Class C pipes as per IS: 3589 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 650 | Meters | 3,950 ₹25,67,500 | 3,385 ₹22,00,250 Lowest | 5,556 ₹36,11,400 |
| 4.00 | Supply, installation, Testing and commissioning of 6 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 600 | Meters | 2,650 ₹15,90,000 Lowest | 2,833 ₹16,99,800 | 3,783 ₹22,69,800 |
| 5.00 | Supply, installation, Testing and commissioning of 5 inch size, 5mm - 5.5mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 7 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 150 | Meters | 2,240 ₹3,36,000 | 1,999 ₹2,99,850 Lowest | 3,343 ₹5,01,450 |
| 6.00 | Supply, installation, Testing and commissioning of 4 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 200 | Meters | 2,350 ₹4,70,000 | 1,550 ₹3,10,000 Lowest | 2,415 ₹4,83,000 |
| 7.00 | Supply, installation, Testing and commissioning of 3 inch size, 5mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | 350 | Meters | 1,265 ₹4,42,750 | 1,200 ₹4,20,000 Lowest | 1,671 ₹5,84,850 |
| 8.00 | Repair/ servicing of Gate/Butterfly Valves - 10 inch | 2 | EA | 4,000 ₹8,000 | 3,200 ₹6,400 Lowest | 4,500 ₹9,000 |
| 9.00 | Repair/ servicing of Gate/Butterfly Valves - 8 inch | 4 | EA | 3,500 ₹14,000 | 2,850 ₹11,400 Lowest | 3,500 ₹14,000 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
18 May 2026, 4:00 pmClosed
DGM - PPMM
AIESL, OAP Mumbai.
Refurbishment of Fire Hydrant Pipeline System that include hydrant line, Valves and accessories in Aircraft maintenance Hangars at OAP, Kalina, Santacruz(E), Mumbai-400029.
2026_AIESL_275876_1
AIESL/BOM/MMD/EFD/02-01A/181
Open Tender
Pipes and Pipe related activities
Works
60 days
OLD AIRPORT, SANTACRUZ (E)
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹1.7 L
Yes
Online
3 Aug 2026
27 Apr 2026
19 May 2026
27 Apr 2026
18 May 2026
5 May 2026
5 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Dismantling | |||||
| 1.1 | Dismantling of existing fire hydrant MS pipeline - 3", 4", 5", 6", 8", 10" | - | Meters | - | - |
| 2Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement: 4 coarse sand) | |||||
| 3Supply, installation, Testing and commissioning of 8 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | |||||
| 4Supply, installation, Testing and commissioning of 6 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | |||||
| 5Supply, installation, Testing and commissioning of 5 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 7 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | |||||
| 6Supply, installation, Testing and commissioning of 4 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | |||||
| 7Supply, installation, Testing and commissioning of 3 inch size, 6 mm thickness, MS black Class C pipes as per IS: 1239 with Tees, Elbows, Couplings, unions, reducers etc. and all such connecting devices that are needed to complete the work of FIRE HYDRANT PIPE LOOP to interconnect existing fire hydrant pipe line network from hangar 2 & 3 pump room to hangar 2 & 3 respectively. Approved Make : TATA/ Jindal | |||||
| 8Repair/ servicing of Gate/Butterfly Valves - 10 inch | |||||
| 9Repair/ servicing of Gate/Butterfly Valves - 8 inch | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.76 MB
Tenderdoc.pdf
Tender Documents • 7.74 MB
BOQ_322198.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .