Loading…
Loading…
Tender Value
₹29.7 L
EMD Value
₹59,328
Closing Date
24 Sept 2026, 11:00 am
Executive Engineer (E)
Town Hall, Jammu
illumination of Vertical Gardens under flyover Vikram Chowk Jammu
2026_HAUDD_323417_1
Electric Division JMC e-NIT No. 14 ELC of 2026-27
Open Tender
Electrical Works
Percentage
All Wards Of JMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Yes
Executive Engineer (E), JMC
₹59,328
Yes
3 Sept 2026
3 Sept 2026
25 Sept 2026
3 Sept 2026
24 Sept 2026
3 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | LED Linear Profile (AC)
Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/RGBNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the
rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over
voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/ RGBNW/ RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 100-270 V AC, 50 Hz with power factor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C
and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver , Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked and shall be complete with all necessary accessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful
bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, Rohs Compliance.
25W
(52 No. Pillar X 2No.= 104 Nos) As per directions by the Engineer Incharge. | 104 | Mtr. | 19,715 | ₹20,50,360 |
| 2 | Supplying, Installation, Testing and Commissioning of underwater Luminaries surface mounted RGB LED spot light 2 x 3W with IP 68 protection, SS/ aluminum dia casting body with power coated paint, soft rubber, gasket along with 3 years free replacement guaranty etc. complete as required.
(52 No. Pillar X 2No.= 104 Nos) As per directions by the Engineer Incharge. | 104 | Mtr. | 4,714 | ₹4,90,256 |
| 3 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in
the existing surface/ recessed steel/ PVC conduit as required.
3 x 2.5 sq. mm
(52 No. Pillar X 10Mtr.= 520 Mtr.) As per directions by the Engineer Incharge. | 520 | Mtr. | 148 | ₹76,960 |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
(52 No. Pillar X 8Mtr.= 416 Mtr.) As per directions by the Engineer Incharge. | 416 | Mtr. | 168 | ₹69,888 |
| 5 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.
200 mm X 150 mm X 60 mm deep
(52 No. Pillar X 1No.= 52 Nos) As per directions by the Engineer Incharge. | 52 | Mtr. | 406 | ₹21,112 |
| 6 | Supplying, Installation, Testing and commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.
1 output per phase and suitable for single phase supply
(52 No. Pillar X 1No.= 52 Nos) As per directions by the Engineer Incharge. | 52 | Mtr. | 4,673 | ₹2,42,996 |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole.
(52 No. Pillar X 1No.= 52 Nos) As per directions by the Engineer Incharge. | 52 | Mtr. | 285 | ₹14,820 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.66 MB
BOQ_1088270.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .