Loading…
Loading…
Tender Value
₹29.3 L
EMD Value
₹58,520
Closing Date
9 Jul 2026, 6:00 pmDue tomorrow
EE PWD DN NEEMKATHANA
EE PWD DN NEEMKATHANA
Repair and Restoration Of Damaged FCW On Udaisinghpura to Ghassipura road in Village Faganwas
2026_CEPWD_571875_5
NIT-11/2026-27 EE PWD DN NEEMKATHANA
Open Tender
Civil Works
60 days
NEEMKATHANA
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Through online eGRAS Challan Neemkathana 12325
₹58,520
Yes
30 Jun 2026
30 Jun 2026
10 Jul 2026
30 Jun 2026
9 Jul 2026
30 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthwork in excavation for structures as per drawing and MoRTH specifications Clause
304.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | - | P.Cum | 137 | - |
| - | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104, P.C.C grade M 10 Nominal mix 1:3:6 | 1 | P.Cum | 2,584 | ₹2,581.42 |
| - | Stone masonry work in cement mortar in foundation complete as per drawing and MoRTH specifications Clauses 1402, 1405, 2102 & 2104.Random Rubble Masonry, In cement mortar 1:4 | 1 | P.Cum | 2,555 | ₹2,552.45 |
| - | Plastering with cement mortar (1:4), 20 mm thick on Stone work. | 1 | Sqm. | 132 | ₹131.87 |
| - | Providing PCC M-20 architectural coping on the top of wing wall, return wall etc. complete as per drawing and MoRTH specification Clauses 1313, 1411 and 2206.6 75 mm thick | - | P.Sqm | 318 | - |
| - | Providing and laying Precast reinforced cement concrete Box culvert section of M-40 grade designed for 'AA' class loading as per IRC specifications including to effect of impact, EQ etc. complete on firm base of 200mm thick lean concrete of M-10 grade with aggregate of size 40mm nominal of following internal size the work includes required safety measures cost of design of RCC Precast Box and its proof checking from IIT / NIT / Government Engineer College complete
in all respect as per specifications Size 2.00 M x 2.00 M | - | P.Mtr | 21,648 | - |
| - | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRTH
specification Clauses 1409, 2204.4, 2206.4 & 2706 | - | No's | 59 | - |
| - | Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials
separately | - | Cum | 515 | - |
| - | Providing laying spreading and compacting specified graded sand, gravel (crushed stone) as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motor grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labor, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH
specification : Clause 401]. By mechanical means.For Grading-II Material | - | Cum | 751 | - |
| - | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10
tonnes vibratory roller, finishing and curing. | - | Cum | 2,418 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.20 MB
Tendernotice_2.pdf
PDF • 11.68 MB
BOQ_1017589.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid