Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹22.3 L+₹2.1 L (10.2%)Rejected-Finance H NO 29 DEVILAL COLONY TCP 2 HISAR CANTT HARYANA | HISAR | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹25.5 L+₹5.2 L (25.6%)Rejected-Finance 182 INDRA COLONY VILL DAMODARPURA POST TODABHATA TEA BASSI BASSI JAIPUR JAIPUR RAJASTHAN 303301 | JAIPUR | RAJASTHAN | 303301 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹27.5 L+₹7.2 L (35.6%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹27.8 L+₹7.5 L (37.2%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L5 | Rejected-Finance Being L5 |
| Sl No | Description | Qty | Unit | M/s Devendera construction L2 | R N Enterprises L5 | M/S KAVITA CONSTRUCTION L1 | KUNAL ENTERPRISES L4 | P S TRADERS L6 | Balaji Construction Co. L3 | M/s Rao Constructions, 1173 Urban Estate-II, Hisar L7 | M/S SURJIT CONSTRUCTION COMPANY L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending of complaints pertaining to unsatisfactory/unfunctional state of solar water heater/ Geyser through telephone or in person on detailment at MES Service centre for Md/OTM accommodation in Hisar Mil Station by rectification of fault of geysers / solar water heater points complete and carrying out repairs to the extent of disconnection and carefully taking down Geysers/faulty wires, sheet metal enclousers, switches & sockets, PVC Connection, conduits, boxes, main switches, MCBs, DBs heating elements, heating plate assembly, glasswool, thermostat, inner and outer tank indicating lamp, pressure release valve, holding / anchor nuts, dead/ safety nuts or any other E/M faults pertaining to particular instrument including wire upto 1.00 mtr and insulation tape required for the rectification of defect and refixing all serviceable/new electrical and mechanical items to existing/shifted location all specified by Engg-in-charge and make good for functional serviceability after repair / replacement of fixtures complete.
Note:- 1.Contractor will provide one geyser/solar water heater mechanic and one helper for daily complaint except Sunday/Holidays
2. Penality will be charged @ 250 Rs per day on absent either mechanic/helper or Both. Note:- Cost of work requiring replacement of other stores will be measured as supply only and paid separately. Contractor shall provide the complaint slip containing 100 pages in duplicate (in two colour) of existing size properly binded and printed all as per sample and directed by Engr-in-Charge. | 1,800 | Per Complaint | 170 ₹3,06,000 | 280 ₹5,04,000 | 100 ₹1,80,000 | 117 ₹2,10,600 | 110 ₹1,98,000 | 80 ₹1,44,000 | 50 ₹90,000 Lowest | 150 ₹2,70,000 |
| 2.00 | M & L for taking out, rectify the faults such as brazing/soldering/welding and making tank leakproof and reinstalling the Solar Water Heater Water supply tanks and Metal frame work in-situ at specified locations with adequate concrete leg support as directed along with repair of water feeding pipe line connections as directed | 30 | Each Job | 800 ₹24,000 | 200 ₹6,000 Lowest | 300 ₹9,000 | 417 ₹12,510 | 200 ₹6,000 Lowest | 200 ₹6,000 Lowest | 200 ₹6,000 Lowest | 450 ₹13,500 |
| 3.00 | Supply and fixing Rubber Ring to connect solar flat plate collector together with nut bolts of size as per existing. | 95 | Each | 200 ₹19,000 | 180 ₹17,100 | 30 ₹2,850 Lowest | 77 ₹7,315 | 50 ₹4,750 | 70 ₹6,650 | 100 ₹9,500 | 40 ₹3,800 |
| 4.00 | Supply and fixing PVC flexible pipe with clamp/tightener to connect solar water heater tank and flat plate collector suitable size as per existing. | 50 | Each | 250 ₹12,500 | 260 ₹13,000 | 60 ₹3,000 | 77 ₹3,850 | 350 ₹17,500 | 50 ₹2,500 Lowest | 100 ₹5,000 | 50 ₹2,500 Lowest |
| 5.00 | M & L for descaling of Solar Water Heater header tanks and tubes of capacity 400 to 500 Ltr including taking down the tank and tubes, checking for leakages and rectification by suitable welding and descaling by using of descaling chemical and H₂SO₄ (as required) and rotating the chemical with the help of closed loop and water pressure pump to completely descale the tank and tubes and re-installing after testing and commissioning complete all as specified and directed.
Note:- The work shall be carried out at the location of tank installed unless specified otherwise. | 33 | Each Job | 500 ₹16,500 | 1,250 ₹41,250 | 500 ₹16,500 | 777 ₹25,641 | 900 ₹29,700 | 200 ₹6,600 Lowest | 300 ₹9,900 | 600 ₹19,800 |
| 6.00 | Supply and fixing in repairs of Solar Water Heater Tubes as per existing suitable for 500 LPD capacity Solar Water Heater System, size of tube is 70mm(OD)x 58mm(ID)x 2170mm(L) or as per existing and made out of copper/brass and including washers, tube caps complete all as specified and directed.
Note:- Make of solar water tube shall be genuine and as per existing make. | 6 | Each Job | 5,200 ₹31,200 | 1,850 ₹11,100 | 600 ₹3,600 | 1,277 ₹7,662 | 1,850 ₹11,100 | 500 ₹3,000 Lowest | 500 ₹3,000 Lowest | 1,000 ₹6,000 |
| 7.00 | Supply and fixing in repairs of Electrical back up of rating 4 KW heating element, single phase, with BSP of 1.1/4" to in Solar Water Heaters 500/400 LPD capacity and including suitable connection wiring complete all as specified and directed.
Note:- Make of electric back up shall be genuine and as per existing make. | 10 | Each Job | 400 ₹4,000 Lowest | 2,550 ₹25,500 | 400 ₹4,000 Lowest | 1,277 ₹12,770 | 850 ₹8,500 | 500 ₹5,000 | 700 ₹7,000 | 550 ₹5,500 |
| 8.00 | Supply and fixing in repairs of temperature based automatic cut off Thermostat used in Electrical Back up of rating 4 KW BSP 1.1/4" suitable for 500/100 LPD capacity Solar water heaters and including suitable connection wiring complete all as specified and directed.
Note:- Make of thermostat shall be genuine and as per existing make. | 12 | Each Job | 200 ₹2,400 | 550 ₹6,600 | 250 ₹3,000 | 277 ₹3,324 | 80 ₹960 Lowest | 300 ₹3,600 | 200 ₹2,400 | 200 ₹2,400 |
| 9.00 | Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I. | 10 | Each Job | 2,900 ₹29,000 | 7,500.2 ₹75,002 | 2,800 ₹28,000 | 2,777 ₹27,770 | 2,500 ₹25,000 Lowest | 3,000 ₹30,000 | 4,500 ₹45,000 | 4,200 ₹42,000 |
| 10.00 | S & F in repairs of 15mm dia fancy type pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe or for brass ferrule complete all as specified & directed. | 15 | Each Job | 250 ₹3,750 | 450 ₹6,750 | 400 ₹6,000 | 477 ₹7,155 | 320 ₹4,800 | 200 ₹3,000 Lowest | 500 ₹7,500 | 280 ₹4,200 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Sept 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Hisar
GE Hisar
REPAIR / MAINT OF ELECTRIC GEYSERS WATER HEATING AND OTHER CONNECTED ITEMS UNDER GE HISAR AT HISAR MIL STN
2025_MES_723595_1
GE(H)-29/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Hisar
As per NIT
6 documents required · 6 mandatory
₹500
Yes
GE Hisar
₹70,000
Yes
23 Sept 2025
31 Jul 2025
10 Sept 2025
31 Jul 2025
2 Sept 2025
18 Aug 2025
Amount
Attending of complaints pertaining to unsatisfactory/unfunctional state of solar water heater/ Geyser through telephone or in person on detailment at MES Service centre for Md/OTM accommodation in Hisar Mil Station by rectification of fault of geysers / solar water heater points complete and carrying out repairs to the extent of disconnection and carefully taking down Geysers/faulty wires, sheet metal enclousers, switches & sockets, PVC Connection, conduits, boxes, main switches, MCBs, DBs heating elements, heating plate assembly, glasswool, thermostat, inner and outer tank indicating lamp, pressure release valve, holding / anchor nuts, dead/ safety nuts or any other E/M faults pertaining to particular instrument including wire upto 1.00 mtr and insulation tape required for the rectification of defect and refixing all serviceable/new electrical and mechanical items to existing/shifted location all specified by Engg-in-charge and make good for functional serviceability after repair / replacement of fixtures complete. Note:- 1.Contractor will provide one geyser/solar water heater mechanic and one helper for daily complaint except Sunday/Holidays 2. Penality will be charged @ 250 Rs per day on absent either mechanic/helper or Both. Note:- Cost of work requiring replacement of other stores will be measured as supply only and paid separately. Contractor shall provide the complaint slip containing 100 pages in duplicate (in two colour) of existing size properly binded and printed all as per sample and directed by Engr-in-Charge.
M & L for taking out, rectify the faults such as brazing/soldering/welding and making tank leakproof and reinstalling the Solar Water Heater Water supply tanks and Metal frame work in-situ at specified locations with adequate concrete leg support as directed along with repair of water feeding pipe line connections as directed
Supply and fixing Rubber Ring to connect solar flat plate collector together with nut bolts of size as per existing.
Supply and fixing PVC flexible pipe with clamp/tightener to connect solar water heater tank and flat plate collector suitable size as per existing.
M & L for descaling of Solar Water Heater header tanks and tubes of capacity 400 to 500 Ltr including taking down the tank and tubes, checking for leakages and rectification by suitable welding and descaling by using of descaling chemical and H₂SO₄ (as required) and rotating the chemical with the help of closed loop and water pressure pump to completely descale the tank and tubes and re-installing after testing and commissioning complete all as specified and directed. Note:- The work shall be carried out at the location of tank installed unless specified otherwise.
Supply and fixing in repairs of Solar Water Heater Tubes as per existing suitable for 500 LPD capacity Solar Water Heater System, size of tube is 70mm(OD)x 58mm(ID)x 2170mm(L) or as per existing and made out of copper/brass and including washers, tube caps complete all as specified and directed. Note:- Make of solar water tube shall be genuine and as per existing make.
Supply and fixing in repairs of Electrical back up of rating 4 KW heating element, single phase, with BSP of 1.1/4" to in Solar Water Heaters 500/400 LPD capacity and including suitable connection wiring complete all as specified and directed. Note:- Make of electric back up shall be genuine and as per existing make.
Supply and fixing in repairs of temperature based automatic cut off Thermostat used in Electrical Back up of rating 4 KW BSP 1.1/4" suitable for 500/100 LPD capacity Solar water heaters and including suitable connection wiring complete all as specified and directed. Note:- Make of thermostat shall be genuine and as per existing make.
Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks (colour other than black as approved by Engineer-in-charge) triple layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I.
S & F in repairs of 15mm dia fancy type pillar tap cast copper alloy with capstan head, chromium plated, screwed down, high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe or for brass ferrule complete all as specified & directed.
S & F in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 25mm bore dia complete all as specified and directed
S & F in repairs of gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe, ISI marked and fixed of size 20mm bore dia complete all as specified and directed.
S & F in repairs gun metal check valve / glove or gate valve 15 mm dia suitable for Geyser of any make/capacity complete. All as specified and directed by Enge in charge.
Supply only pressure release valve 15mm dia suitabel for existing geyser complete.
Supply only geyser heating element 1500 watt, 230 V, 50HZ suitable for any type, size & make of geyser. All as specified and directed by Enge in charge.
Supply only geyser heating element 2000 watt, 230 V, 50HZ suitable for solar water heater of any type, size . All as specified and directed by Enge in charge.
Supply only thermostat / cut off of geyser suitable for any type, size & make of geyser as per existing range 15-75 degree temperature.
Supply only PVC Cable of size 2.50sqmm 3 core copper conductor round type.
Supply only indicating lamp round type suitable for Geyser any type, make & capacity
Supply only stainless steel Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 50 Ltr Capacity Geyser of any type and make complete.
Supply only stainless steel Heating plate assembly with water inlet & outlet, rubber gasket, nuts and bolts and washers of required size suitable for 25 Ltr Capacity Geyser of any type and make complete.
Supply only glass wool for geyser vessel of any size and capacity complete.
Supply only mild steel holding/anchor bolts and nuts machine made of size 10cm to 15cm long and dia of bolt 10mm to 15mm complete. Note :- Anchor bolt shall be grouted with hammer drill only.
Supply only dead nut/Safety plug of brass as per sample suitable for Geyser of any capacity/make. All as specified and directed by Enge in charge.
Supply only inner tank of geyser capacity 25 ltr made out of 16 SWG sheet Steel suitable for Geyser of any type and make to match the existing size and shape of inner tank of Geyser installed at site. All as specified and directed by Enge in charge.
All as per Srl item No 25 above but for Geyser of capacity 50 ltrs. All as specified and directed by Enge in charge.
Supply only outer tank of geyser made out of GI sheet of existing gauge, shape including top and bottom cover plate complete suitable for inner tank 25 ltr capacity geyser of any make complete. All as specified and directed by Enge in charge.
All as per item No 27.00 but suitable for 50 ltr capacity geyser. All as specified and directed by Enge in charge.
Supply only metal clad plug Socket 20 Amp (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.
Supply only metal clad plug top 20A (enclosure type) suitable to fix in sheet and metal enclouser for geyser. All as specified and directed by Enge in charge.
Supply only hot water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge.
Supply only Cold water PVC connection of 15mm bore heavy duty, length upto 45cm with brass nut joints and washers at both ends complete. All as specified and directed by Enge in charge.
Supply only sheet metal single pole and neutral enclosure with one SPN MCB of 20 Amp rating 240volt and a 2 pin and earth plug and socket complete all as specified and directed by Engg-in-charge.
Taking down unserviceable geysers 25/35/50 litre capacity of any make opening up for inspection, inlet, outlet and thermostat pipe, washing the inner tank with anti corrosion solution , the inlet & outlet valves, safety valve, dead weight and refixing the geysers in position and testing for proper functioning including soldering/welding where required to stop the leakage and other jobs connected with plumber and mason which would be required in connection with making the geyser functional complete.
Supply only MCB, SPN 32 AMP, 240V, 10 KA (B Curve) complete. All as specified and directed by Engg in charge.Make-L&T,Havells, Polycab,HPL,Benlo,Indo Asian
Supply only MCB, SP 20 AMP 240 V 10 KA (B Curve) complete. All as specified and directed by Engg in charge.
M&L for Sub main wiring with 2 run of single core 6 Sqmm FRLS PVC insulated unsheathed cable, 1100v grade with copper multi stranded conductor drawn through and including surface PVC conduit ISI marked medium grade 20mm dia with all fitting and fixing accessories including of 6 Sqmm FRLS PVC insulated unsheathed Copper cable green colour as earth wire connected to earth including taking down existing sub main wiring complete.
All as per serial item 37.00 here in before but with 2 run of single core 4 Sqmm cable with 4.0 sqmm earth wire. All as specified and directed by Enge in charge.
M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including concealed PVC rigid non metallic conduit 20mm dia medium grade (ISI marked) with all fittings such as tees, bends etc including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed.
M&L for point wiring for one light point controlled by one, one way switch with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into existing PVC conduit / PVC casing caping concealed / fixed in wall or surface or ceiling including sunk type pressed steel box covered with and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed.
Supply only plug top 15/16 Amp all as specified and directed.
Supply only bottom split inspection cover for geyser of capacity 25 litres of any make.
Supply only bottom split inspection cover for geyser of capacity 50 litres of any make.
Supply in replacement flush type socket outlet multipurpose 3 Pin 6/16 Amp (with 2/ 3 pin combind2 module ISI marked complete all as specified and directed.
Supply in replacement only switch piano flush type, single pole, one way, 16/20 Amp, 230 Volts 1 module ISI marked complete all as specified and directed. .
Taking down carefully copper/aluminum point wiring (light/fan/socket or power) complete including taking out existing unserviceable terminal boxes & conduit with switches/sockets/fan regulators and fittings such as ceiling rose, pendants, tube light fittings, lamp holders, brackets light fittings, rectangular blocks etc. and making good disturbed surface of walls, floors etc. to match with the existing surface etc complete all as specified and directed.
S&F in repairs galvanized steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed. Note: Cost of aluminium casing if required is also included in this item
S&F in repairs galvanized steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed. Note: Cost of aluminium casing if required is also included in this item
S&F in repairs galvanized steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed. Note: Cost of aluminium casing if required is also included in this item
S&F in replacement CPVC pipes (Inner dia of pipe 25mm) SDR 11 & Plain CPVC SDR 11 fittings laid on wall / ceiling or laying in floor complete all as specified with all fittings / connections and making good to required surfaces by using white cement / masonry works complete all as specified and directed. Note :- Rates quoted shall deemed to be included for making hole / nitch for replacement of pipe and making good distrubed surfaces to match with existing surface and finish all as directed.
S&F in replacement CPVC pipes (Inner dia of pipe 20mm) SDR 11 & Plain CPVC SDR 11 fittings laid on wall / ceiling or laying in floor complete all as specified with all fittings / connections and making good to required surfaces by using white cement / masonry works complete all as specified and directed. Note :- Rates quoted shall deemed to be included for making hole / nitch for replacement of pipe and making good distrubed surfaces to match with existing surface and finish all as directed.
S&F in replacement CPVC pipes (Inner dia of pipe 15mm) SDR 11 & Plain CPVC SDR 11 fittings laid on wall / ceiling or laying in floor complete all as specified with all fittings / connections and making good to required surfaces by using white cement / masonry works complete all as specified and directed. Note :- Rates quoted shall deemed to be included for making hole / nitch for replacement of pipe and making good distrubed surfaces to match with existing surface and finish all as directed.
Supply and fix in repair Solar flat plate collector device duly glazed with insulated material to block infrared radiation having absorbing plate, copper tubes, insulation/glazing cover and casing/container for closure for the components of the flat plate solar collector, compatible to connect with existing solar water heater system of capacity 200ltr to 500 ltrs in series/ parallel as per existing having facility to drain out the water from bottom with brass flared flanged end connection and tested by BIS as per IS 12933:2023. Size of collector should not be less than 1050*2160mm(width*length).
Supply and fix in repair toughened glass sheet 5 mm thick minimum duly glazed with insulated material all as specified and directed by Engr-in-charge.
Supply and fix in repair Solar water heater tank of capacity 150LPD minimum, inner tank made out of Stainless steel SS-304L for long lasting life with high quality PUF insulation, having provision of electricity backup up to 4/5 KW including thermostat, auto cut, pressure releasing provision. Tank should have provision for connection with flat plate collector all as specified and directed by Engr-in-charge.
Supply and fix in repair Solar water heater tank of capacity 300LPD minimum, inner tank made out of Stainless steel SS-304L for long lasting life with high quality PUF insulation, having provision of electricity backup up to 4/5 KW including thermostat, auto cut, pressure releasing provision. Tank should have provision for connection with flat plate collector all as specified and directed by Engr-in-charge.
Supply, fabricating, bending, welding and fixing in replacement of iron work for solar water heater system stand as per existing size made out of angle iron flat and including grouting in the wall/roof and provision of nuts. Bolts and washers including painting with one coast of primer and two coasts of syntetic enamel paint compete all as specified and as directed by Engr-in-charge.
M&L for PCC Type C2 (1:3:6) in foundation fillin work including demolition of existing etc all as specified and directed
M/s Devendera construction (BID ID -3403101)
Balaji Construction Co. (BID ID -3413859)
KUNAL ENTERPRISES (BID ID -3406803)
R N Enterprises (BID ID -3405558)
P S TRADERS (BID ID -3407198)
M/s Rao Constructions, 1173 Urban Estate-II, Hisar (BID ID -3414385)
M/S SURJIT CONSTRUCTION COMPANY (BID ID -3413733)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .