Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹25.7 L+₹41,178 (1.63%)Rejected-AOC FLAT NO 1 179 GANESH NAGAR S NO 10 YERAWADA PUNE 411006 | PUNE | MAHARASHTRA | 411006 | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹27.9 L+₹2.6 L (10.3%)Rejected-AOC | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹30.8 L+₹5.5 L (21.7%)Rejected-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L4 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
3 Feb 2022, 6:00 pmClosed
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8304 REPAIRS / MAINTENANCE AND CLEANING OF SEWAGE LINES, MANHOLES AND SANITARY FITTINGS IN TOILET AT NEW COMMAND HOSPITAL PUNE UNDER GE SOUTH PUNE
2021_MES_484970_2
8304 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹66,000
Yes
26 Feb 2022
6 Jan 2022
5 Feb 2022
6 Jan 2022
3 Feb 2022
22 Jan 2022
Amount
Cleaning and rodding the blocked sewage line to any depth till the smooth flow of sewage line is restored including plugging of manholes temporarily as and when required and washing down complete sewage line with water including removing sludge and foreign materials from manholes in line and removing and refixing manhole covers and rodding complete all as directed for following size of pipes :-
150 mm bore
200 mm bore
250 mm bore
300 mm bore
Day to day maintenance and petty repair of sewage line (complaints pertaining to safaiwala) by attending daily complaints lodged by the users through IVRS / mobile / SMS / email and manual registering of complaints at B/R complaint cell on all working days (except Sunday, National Holidays and Closed Holidays) by deploying 03 (Three) Safaiwala per day, complete all as specified and directed by Engr-in-charge. [Note : (i) Minor complaint shall be completed within 24 hours and major complaints with in a week. (ii) If safaiwala not attended complaint within time frame mentioned above 50 % shall be deducted job completed by him. (iii) The contractor will be responsible to maintain daily job completed by the safaiwala deputed by him in the sub work and obtained signature of I/C complaint cell/Engr-in-Charge daily at 1700 hours on all working days.]
Cleaning of manholes of any size and of any depth by taking out semi solid/solid sludge complete and removing sludge in covered vehicle out of MOD land complete all as specified and as directed.
Dewatering of tank & cleaning of all dirt, waste precipited materials & washing by using bleaching powder & cleaning with fresh water and removing particles from OHT exc 50000 gallons but not exc 1.10 lakhs gallon etc complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundations, manholes etc and getting out in hard /dense soil complete all as specified and as directed.
All as per item 5.00 above but exc 1.5m depth and n. Exc 3.0mtr in depth complete all as specified and as directed.
Demolition and breaking up RCC, drain pipes set in cement mortar for the following sizes and removing debris from the site complete all as directed by Engr-in-Charge :-
150 mm bore
200 mm bore
250 mm bore
300mm bore
Demolition of cement concrete of any description and in any position not otherwise specifically provided for
M&L for RCC pipes class NP-3 with socketed ends laid and jointed complete with cement joints of 150mm bore complete all as specified and as directed. (Note :- Laying of sewage line in running sewage water & temporary diversion /plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate for the same is seems to be included in the contract)
All as per item 9.00 above but 200mm bore complete all as specified and as directed.
All as per item 9.00 above but 250mm bore complete all as specified and as directed.
All as per item 9.00 above but 300mm bore complete all as specified and as directed.
M&L for PCC 1:4:8 type D2 using 40mm graded agg as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150mm bore pipe complete all as specified and as directed.
All as per item 13.00 above but 200mm bore.
All as per item 13.00 above but 250mm bore.
All as per item 13.00 above but 300mm bore.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm in soil complete all as specified and as directed.
Removing the excavated surplus soils not exc 50mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required, for the following size of pipe :-
150 mm bore
200 mm Bore
250 mm bore
Demolition of brick work or stone/boulder masonry, built in cement mortar complete all as specified and as directed.
S&F in repair Cast iron work grade Fe-150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 as in foundations, filling in mass concrete etc complete all as specified and as directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:3:6) 20mm gde aggregate and setting in CM 1:6 complete all as specified and as directed
M&L for rendering 10mm thick on fair faces of concrete surface in CM (1:4) mixed with WPC as per manufacturer’s instructions by weight of cement, finished fair and even without using extra cement complete all as spd and directed. (Note : WPC shall be measured and paid separately as ‘Supply only’)
M & L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels and drains (including necessary form work) complete, all as specified and directed.
M&L for PCC (1:2:4) type B-1 using 20 mm stone graded aggregate as in benching, coping etc complete complete all as specified and as directedl
M&L for providing precast RCC M-20 type A-1 using 20 mm graded stone aggregate in Manholes covers and slabs set in CM 1:6 complete all as specified and as directed.
M&L for TMT bars 6mm to 8mm dia cut to length, bent to shape required, bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed,
M&L for CI floor/Nahani trap with grating 75mm dia including jointing to waste pipe removing old traps complete.
S&F in repairs vitreous china wash down water closet pan, 'Pedestal' coloured, including fixing bolts etc including PVC seat cover white with flat bottom including MS, CP or aluminium anodised hinges devices etc complete all as specified and directed.
S&F in repairs, PVC seat cover white with flat bottom for vitreous china wash down water closet pan including MS, CP or aluminium anodised hinging device etc complete all as specified and directed.
S&F in repairs PVC Connection pipe 450mm long complete all as specified and as directed.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
S&F in repair vitreous china wash hand basin white flat back size 550x400mm incl brackets, PTMT waste coupling, 32 mm bore GI waste pipe complete all as specified and as directed.
S&F in repair vitreous china wash hand basin with pedestal snow white 630x480mm flat back inclduing and providing waste pipe 40mm bore medium grade, CP brass waste coupling 32mm bore with check nut washer etc fixed complete all as specified and as directed.
S&F in repair for 10 litres capacity PVC Valveless and Syphonic action type flushing cistern low level including ball valve inlet & outlet connection 15 mm bore PVC pipe with check nuts on both ends, PVC waste pipe 32 mm bore upto WC connection and GI 15 mm bore overflow pipe upto floor level complete all as specified and as directed.
S&F in repair fancy type, Pillar taps, cast copper alloy , with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and as directed.
S&F in repair Tubular towel rail, Brass chromium plated 20mm dia, D type, 60cm long between flanges all as specified and directed.
S&F in repairs soap dish vitreous China white, approximate size 160x160x90mm complete all as specified and directed.
Taking up or down steel tubing & connection incl cleaning for refixing or removal from site for 15 mm bore pipe complete all as speicified and directed.
All as per Sr. item No 41.00 above but of 20mm bore pipe.
M & L for cutting chases for concealed water tubing, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges etc, cutting not exceeding 10 cm width or girth, complete all as specified and directed.
Refixing old steel tubing of 15 mm /20 mm bore and connections in new or old position (walls, ceilings, floors etc.) complete all as specified and directed
S & F 15 mm bore Galvanized Steel tubes, medium grade for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as specified and directed.
All as per Sr. item No 45.00 above but 20mm size.
S&F in repair CI Hubless pipe of dia 150 mm fixed to walls with necessary fittings and clamps complete all as specified and as directed.
S&F in repairs CI hubless dia reducer tee (single branch plain Tee) 150x150x100mm complete all as specified and as directed.
S&F in repairs only SS shielded coupling 150mm bore complete all as specified and as directed.
S&F in repairs CI hubless bend 150 mm bore complete all as specified and as directed.
S&F in repair CI Hubless pipe of dia 100 mm bore fixed to walls with necessary fittings and clamps complete all as specified and as directed.
S&F in repairs hubless dia reducer tee (single branch plain T) 100x10x100mm complete all as specified and as directed.
S&F in repairs SS shielded coupling 100mm bore complete all as specified and as directed.
S&F in repairs CI hubless bend 100 mm bore complete all as specified and as directed.
S&F in repairs CI hubless 150x100 mm bore Dimminshing pieces (Reducer) complete all as specified and as directed.
S&F in repairs PVC waste pipe 32/40mm dia 610mm long suitable for WHB or Sinks etc complete all as specified and directed.
Taking down chowkats or frames with shutters not exc. 1.5 sqm (without taking off shutters from the frame) and removed to store complete all as specified and as directed.
Taking down shutters of any description exc 1 sqm and not exc 2 sqm each complete all as specified and as directed.
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with M.S square tube, supplying & fixing in opening as per specifications, drawings complete all as specified and as directed.
S&F factory made solid prelaminated PVC door shutter 30mm thick (style) consisting, of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat molded plain co lour PVC ‘C’ channel having a PVC sheet strip of 20mm width struck inside with solvent cement for steel & plain co lour PVC sheets for top rail, lock rail& bottom rail on either side & or gap insert for top rail & bottom rail, paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet banding, and joints to gather with solvent cement, supplying & fixing in the frame at site as per specification & drawing.
S & F 100 mm long butt hinges medium weight , cold rolled Mild steel for door shutters complete all as specified and as directed.
S&F 150 mm aluminium anodized barrel tower bolts of extruded section for door shutters complete all as specified and as directed.
S&F in repair 150 mm aluminium anodized barrel tower bolts of extruded section for door shutters complete all as specified and as directed.
S & F 250 mm long aluminium alloy , anodised sliding door bolt with hasp , staple( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast - aluminium alloy and fixed complete all as specified and as directed.
S & F in repair 250 mm long aluminium alloy , anodised sliding door bolt with hasp , staple( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast - aluminium alloy and fixed complete all as specified and as directed.
S & F 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S & F in repair 150 mm extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for coloured glazed Ceramic tiles 450x300x7to8mm thick in vertical surfaces such as skirting dado set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick rendering in cement mortar 1:4 on stone / brick/ concrete masonry surfaces complete all as specified and as directed.
M&L for Non skid ceramic coloured tiles 7to8mm thick, (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc.set and jointed in neat cement slurry & pointed in white or coloured cement to match.including 15mm thick screed bed or bedding layer as in CM 1:6 complete all as specified and as directed.
Demolition and breaking of drain pipes AC /CI/PVC set in cement mortar or adhensive all as directed of 75mm to 110 mm bore complete all as specified and as directed.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in earth of 110 mm bore complete all as specified and as directed,
All as per Sr. Item No 72.00 above but 75mm bore.
S&F PVC (SWR) bends plain 110 mm bore.
All as per Sr. Item No. 74.00 above but 75mm bore.
S&F PVC SWR Branch piece single (Single Y) equal or unequal 110mm bore with door access complete all as specified and as directed.
All as per Sr. Item No. 76.00 above but 75 mm bore.
S & F PVC (SWR) branch piece, double (double Y) equal or unequal 110mm bore with door access complete all as specified and as directed.
All as per Sr. Item No. 78.00 above but 75mm bore.
S&F PVC (SWR) of 110mm bore junction single (single 'T') equal or unequal with door access complete all as specified and as directed.
All as per Sr. Item No. 80.00 above but 75 mm bore.
Supply only integral water proofing compound complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of concrete surface in CM (1:6) finished fair and even without using extra cement complete complete all as specified and as directed.
M&L for mild steel round bars, 12mm dia and above as in rungs in manhole, handle for manhole cover and similar articles of quality conforming to Fe-410 or Fe-310 complete all as specified and as directed
TULSAYA CONSTRUCTION
Takshashila electricals
R k construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .