Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.6 LAccepted-AOC 01 SARAI BEERBHADRA BIR BHADRA ROAD NEAR JMS COACHING CENTER PRATAPGARH UTTAR PRADESH 230502 | PRATAPGARH | UTTAR PRADESH | 230502 | 1 | Accepted-AOC ok |
Tender Value
₹1.7 L
EMD Value
₹3,500
Closing Date
1 Dec 2021, 2:00 pmClosed
Executive Engineer Electrical Najafgarh Zone
SOUTH DELHI MUNICIPAL CORPORAIONOFFICE OF THE EXECUTIVE ENGINEER ELECT NGZ ROOM NO -219, II ND FLOOR, ZONAL OFFICE BUILDING, DHANSA STAND , NAJAFGARH, NEW DELHI-110043
Construction of Toilet Block in DDA MLU market Sector -6 Pocket II Dwarka in Ward No- C -38S under NGZ Sub Head Provision of EI and Fans
2021_SDMC_95885_1
EE/Elect/Najafgarh Zone /2021-22/ 24
Open Tender
Electrical Works
Item Rate
120 days
Najfgarh Zone SDMC
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
₹3,500
Yes
5 Jan 2023
24 Nov 2021
2 Dec 2021
24 Nov 2021
1 Dec 2021
24 Nov 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. (a) 2x2.5 sq.mm +1x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. (b) 4x2.5 sq.mm +2x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. (b) 2x4 sq.mm + 1x4 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. (b) 4x4 sq.mm + 2x4 sq.mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface / recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 6 SWG dia GI wire on surface or in recess for loop earthing along withsurface/ recessed conduit/ submain wiring/cable as required.
Installation of exhaust fan in the existing opening ,including making good the damage,connection,testing,commissioning etc.as required. (a) Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) Double Pole
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable for working voltage upto 1.1 KV Conforming to IS 7098 of following Sizes. 2x 25 Sqmm
SITC of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12 - 30 meter , suction and delivery 25X25 mm
Supply of 15'' ( 380 mm )sweep 1400 rpm exhaust fan heavy duty complete with shutter,blade etc as required
S.I.T.C LED tubelight type luminaire 20 watt rating complete with extruted alluminium batten prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
S.I.T.C of 60watt LED flood luminiare fitted with lens , made of pressure die cast alluminium housing & toughened glass cover complete with the following specification as required .(A) Total system wattage 60 watt+/- 5% ,(B) Luminous efficiency >= 100 Lumens/watt, © Power factor >= 0.95,(d) Protection class -IP-66
Supply of 50 mm dia. G.I. pipe (medium class)
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required . Above 4.5 metre and upto 6.5 metre
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply of 9/10watt LED retrofit Lampsuitable for B22 Holder
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx 160 mmx 98 mm complete with suitable arrangement for fixing of two nos.of 6 to 32 amp single pole MCB and 63 amp double pole isolator (MCB excluded) with neutral link duly shorting on DIN channelwith 2 nos.of MS clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .