Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.3 L+₹80,071 (2.54%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹34.7 L+₹3.2 L (10.3%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹35.5 L+₹4.0 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹38.0 L+₹6.5 L (20.6%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹36 L
EMD Value
₹72,000
Closing Date
29 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
Junglighat PO Port Blair
PROVISION OF SERVO STABILIZER FOR ATC AND ACHR AT INS UTKROSH UNDER GE MINNIEBAY, PORT BLAIR
2022_MES_554729_1
8165/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹72,000
Yes
10 Dec 2022
28 Sept 2022
1 Nov 2022
28 Sept 2022
29 Oct 2022
15 Oct 2022
60 days
Amount
Supply, install and testing of Voltage stabilizer 300 KVA, automatic operation, three phase, copper winding E Class> 6 Mega ohms, efficiency not less than 95%, naturally oil cooled, indoor type, designed for input variation between 360 V to 480 V with output voltage stabilized at 415 volt with accuracy ± 1% and speed of correction not less than 6 Volts per second confirming to BIS 9815 (Part I) complete all as pre manufacture's instruction and as directed by Engr-in-Charge
Supply, install and testing of Voltage stabilizer 400 KVA, automatic operation, three phase, copper winding E Class> 6 Mega ohms, efficiency not less than 95%, naturally oil cooled, indoor type, designed for input variation between 360 V to 480 V with output voltage stabilized at 415 volt with accuracy ± 1% and speed of correction not less than 6 Volts per second confirming to BIS 9815 (Part I) complete all as pre manufacture's instruction and as directed by Engr-in-Charge
Note for item No 1 & 2 (i) Stabilizer shall be confirming to BIS 9815 (Part 1) - 1994 (Second Revision (ii) The corrector shall keep the output voltage within +/- 1% of the rated voltage irrespective of load and input voltage range as per clause 9.1 of BIS (iii) Speed correction - The rate of correction of voltage shall not be less than 6 V/s between phase and neutral. The corrector shall free from hunting during automatic operation as per clause 9.3 and 9.4 of BIS. (iv) Losses - The manufacturer shall state no load and full load losses corresponding to minimum and maximum rated input voltages. The tolerances on these declared values shall be provided in table 7 of IS 2006 (Part I) : 1977, The no-load current shall not be more than 5% of the rate out put current as per clause 9.4 & 9.5 of BIS. (v) Efficiency - The efficiency of servo voltage stabilizer shall be not less than 95% as per cluase 9.6 of BIS. (vi) Acceptance tests - The testing of servo stabilizer should be carried out in accordance with Para 11.2 of the BIS 9815 (Part 1) (Reaffirmed 2004). The following constitute acceptance tests:- (a) Physical examination, (b) Insulation resistance (c) High voltage test (d) leakage current test (e) Provision for earthing (f) Output voltage (g) No load current (h) Measurement of no load losses (j) Induced voltage test
Note contd/-- (vii) Break down strength 2500AC for 2 Minute (viii) Insulation Resistance - More than 100 Mega ohms at 500V DC (ix) No load loss - Less than 2.5% and Full load loss - less than 3% (x) High and low volgate cut off, by pass arragements, single phase preventor & silent operation with 1st filling of oil (IS 335 : 1953 reaffirmed 2005) (Qty of oil shall not be less than 820 Ltr for 400 KVA and 500 Ltr for 320KVA ) (xi) Contractor shall submit test reports from the manufacturer for above capacity from Govt Lab / NABL accredited Lab while submitting RAR/FB for payments
Supply and fix ON LOAD change over switch box type 415 volt in sheet metal enclosures 4 pole, 250 Amps , 36 KA complete all as specified and as directed by Engr-in-Charge
Supply and fix ON LOAD change over switch box type 415 volt in sheet metal enclosures 4 pole, 400 Amps, 36 KA complete all as specified and as directed by Engr-in-Charge
Supply, laying and testing LT underground XLPE cable insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 Sqmm 3.5 Core complete all as specified and as directed by Engr-in-Charge
Supply, laying and testing LT underground XLPE cable insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 Sqmm 3.5 Core complete all as specified and as directed by Engr-in-Charge
Supply & laying DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103.5mm polyethylene including couplers, bends, cap etc.with smooth internal and profiled external surface complete all as specified and as directed by Engr-in-Charge
Supply and laying 80mm bore GI tubing medium grade ISI marked for cable protection in trenches/duct/fixing to pole/wall or in such similar position including road cutting complete all as specified and as directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and not exceeeing 1.5 mtr depth and getting out in soft / loose soil complete all as specified and as directed by Engr-in-Charge
Excavation in trenches not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out in hard / dense soil complete all as specified and as directed by Engr-in-Charge
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed by Engr-in-Charge
Removal of surplus soil not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5mtrs above the starting point complete all as specified and as direted by Engr-in-Charge
Material and Labour for plain cement concrete 1:4:8 type D2 (Nominal Mix) using 40mm graded stone aggregate for foundation, filling complete all as specified and as directed by Engr-in-Charge.
Material and Labour for for providing earthing complete with Copper earth plate electrode 600 mm x 600 mm x 3.15mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to copper earth strip 20 x 3 mm by means of bolts, nuts, checknuts & washers of copper and connecting to earth dolly all as shown in electrical plate No. 3 of SSR Part I of 2009 & & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including copper earth strip 20 x 3 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and as directed by Engr-in-Charge. Note: (i) Cost of earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (vi) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
S&F copper strips of 20x3mm size laid in trenches/wall/floor etc including necessary earthwork complete all as specified and directed by Engr - in - Charge .
SHUSHANT ASSOCIATES
vijay kumar gupta and co
M/S ISLAND REALCON INDIA PVT. LTD
A. R. ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .