Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-Finance | L1 | Accepted-Finance Ist Lowest bidder | |
| 2 | L2₹14.5 L+₹31,368.80 (2.22%)Accepted-Finance | L2 | Accepted-Finance IInd Lowest bidder | |
| 3 | L3₹14.9 L+₹76,502.10 (5.40%)Accepted-Finance | L3 | Accepted-Finance IIIrd Lowest bidder |
Tender Value
₹14.2 L
EMD Value
₹14,200
Closing Date
15 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
EDC I Saharanpur
Business plan 2025-26 works in the area of EDD Sarsawa
2025_PVVNL_1070052_1
26/W/EDC-I/SRE/2025-26
Open Tender
Electrical Works
Lump-sum
60 days
saharanpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Yes
SE EDC I SRE
₹14,200
Yes
25 Sept 2025
30 Aug 2025
15 Sept 2025
30 Aug 2025
15 Sept 2025
30 Aug 2025
Amount
Detail of Work
Safe cartage of Line Matrial from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safely cartage of PCC Pole 8.5/9/11 Mtr. Long from ESC, SRE to the site of work including loading unloading at both ends. (Dist. up to 20 KM.)
Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safely Carriage of 11 KV Bus Coupler 1250 A from ESC SRE to site of work including loading and unloading at both ends.
Safe cartage of 11 KV Fuse Set from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safe cartage of 11 KV TPMO from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safely Carriage of 33 KV Line Isolator 800 Amp from ESC SRE to Site of work including loading and unloading at both ends.
Safe cartage of ABC Conductor from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safe cartage of Dog Conductor from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safely Cartage of 11 KV XLPE Cable (3x1850sq.mm) from ESC SRE to Site of work including loading and unloading at both ends.
Safe cartage of DO Fuse Set 3 phase from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safe cartage of 33 KV Fuse set from ESC,SRE, to the site of work including loading & unloading at both ends. (Dist. Upto 20 km.)
Safely Cartage of 33 KV XLPE Cable (3x300sq.mm) from ESC SRE to Site of work including loading and unloading at both ends.
Safe carriage of 33 KV CT 200/100/1-1-1A from ESC SRE to Site of work including loading and unloading at both ends.
Safely Installation of DO Fuse set and connection properly.
Safely Installation of 33 KV CT and connection properly.
Safely Installation of 33 KV Fuse set and connection properly.
Safely Installation of 11 KV Bus Coupler1250A and connection properly.
Safely Installation of 33 KV Line Isolator and connection properly.
Safely Installation of 11 KV Fuse set and connection properly.
Safely Installation of 11 KV TPMO and connection properly.
Laying of 33 KV XLPE Cable size 3x300 sq,mm
Laying of 11 KV XLPE Cable size 3x185 sq,mm
Making and Filling the 33 KV cable jointing kit Indore & outdoor type size 3x300 Sqmm. sq.mm as per RESPO specification.
Making and Filling the 11 KV cable jointing kit Indore & outdoor type size 3x185 Sqmm. sq.mm as per RESPO specification.
Erection of single support on PCC Pole up to 8.5/11Mtr Long with complete fitting of all accessories of 33 KV & 11 KV/LT as per RESPO specification
Fixing of 33 KV stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/8 SWG and fitting the same on the pole
Fabrication work of Channel & Angle
Grouting of Pole
Structure for 33 KV Line Isolator some civil work
Fencing of Line Isolator asper RESSPO specification.
Chemical Earthing
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Dog Conductor for 33KV/11KV/LT Line including complete.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR weasel Conductor for 11KV/LT Line including complete.
Constriction of plinth for installation of 250 kv T/F of size 2x2x1.5 mtr made of 9”inch thick wall in all four sides with 6”inch thick RCC top duly filled with sand and plastered 12mm thick in ratio 1:4 with cement and sand on outer surface of brick wall.
Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning.
Wire mesh fencing of 250 KVA T/F size 2.5x2.5x2.5 mt. grouting making frame of MS angle 45x45x6 mm and fixing four no. MS strip size 25x6 mm at equal distance in between the frame and fixing square mesh 50 mm square in each frame the fencing should cover all side of T/F with providing 1 No. door size 6'x3' with sitakni & Dandala.
01 No Water Level Neutral Earthing of 11 KV VCB Bus Coupler and Water Level Earthing of 250 KVA T/F (1 No body & 1 No. neutral earthing) by boring of 60 Ft deep & fixing of 60 ft. G.I pipe 11/2" Dia (Jindal Class B) and connecting with G.I. Strip of size 40x5 mm and G.I wire at bottom of G.I pipe to the T/F providing of required charcoal & salt in the pipe
Providing and fixing of Double Circuit Tail less unit 350 Amp in coming circuit connected with copper bus bar of proper ratting for 160/250 KVA T//F in the frame made of MS Angle 45x45x5 mm fitted with GI Nut bolts and fixing the same top of plinth/near ground level as per site requirement.
Laying of LT PVC cable 1*400 sq.mm sq.mm as per repo specification.
Providing and fixing of COPPER L-PIECE 50X225X10 MM
Providing and fixing of AI LEG LONG BARREL OFF SIZE (LS)
Providing and fing of DANGER BOARD
Providing and fixing of BARBED WIRE
Providing and fixing of LT INCOMING PANNEL WITH METERING EQUIPEMENT
Providing and fixing of Aluminum Lug
Providing and fixing of Holding clamp
Providing and fixing of Nut & Bolt
Providing and fixing of All type Clamp
Providing and installation of WTI Meter For Power T/F
Providing and installation of OTI Meter For Power T/F
Providing and fixing of J-Hook
Providing and fixing of LT piercing Connector 95 sq.mm
Providing and fixing 3 Phase Distribution box Clamp
Providing and fixing of Electronic (E/F/& O/C PROTECTION RELAY
EARTHING ROAD COMPLETE
Guarding work (1 span)
Removal of 100 kva t/f from the D/P and cartage site of work to ESC SRE including loading and unloding at both ends
Removal of old and used dog conductor and making roll site of work to ESC SRE including loading and unloding at both ends
Removal of old and used X-arm site of work to ESC SRE including loading and unloding at both ends
Safely removal of old and used 11 KV Bus Coupler from Site to ESC SRE including loading and unloading at both ends.
Safely removal of old & used/damaged 33 KV CT from Site to ESC SRE including loading and unloading at both ends.
Safely removal of old & used/damaged 33 KV Line Isolator from Site to ESC SRE including loading and unloading at both ends.
Laying, lifting, Stringing, proper sagging ABC cable of size 3x120 sq.mm. including fixing of all accessories.
Safely Fixing of 3 phase distribution Box properly.
Fixing of stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/10 SWG and fitting the same on the pole
Safely Fixing of 33 KV Polymeric Pin insulator
Safely Fixing of 33 KV Polymeric Disc insulator
Safely Fixing of 33 KV X-arm
Laying of Connecting lead 1x16 sq.mm/LT PVC Cable 3x150
FAGGU RAM & COMPANY (BID ID -5534814)
RAJ ENTERPRISES (BID ID -5534841)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .