Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹3.5 L
Closing Date
1 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Re-Electrification in Instrument Lab and Faculty Room in the Department of Bio-Chemistry.
2022_UDJK_169595_1
F(E.Tend)(UCD)/KU/11/22
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Main Campus
As per NIT
3 documents required · 3 mandatory
₹200
Registrar University of Kashmir
Exempted
2 Jun 2022
18 May 2022
2 Jun 2022
18 May 2022
1 Jun 2022
18 May 2022
120 days
Amount
Supply , laying and fixing of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, un armoured, served, sheathed 1100 volts grade. 25 sqmm 2 core
Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
single pole
Double pole
Supplying and fixing 40 - 63 A rating, 240/415 V, “C”-curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. Double pole
Providing and fixing of 12way Double door distribution Board
Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note :Rates of Suitable PVC conduit included in above description for the follwing items
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
2 x 6 sq.mm + 1 x 6 sq.mm earth wire
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring
Providing and fixing of Heating points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 6/16 Amp. of Modular Switch, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all aspects note: all items included like Conduit, wire, MS box, switches, cutting the wall and making good the same etc.
Providing and fixing of Lighting point wiring in Loop with 1.5 mm2 PVC insulated copper wire of FRLS through heavy duty PVC conduit pipe with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular switches, plate & MS box of required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, MS junction box, wire, box, switches, cutting the wall and making good the same etc.
Providing and fixing of fan/ light point wiring with 1.5 sq. mm PVC insulated copper wire of FRLS through heavy duty PVC conduit with all necessary accessories including providing and fixing of ceiling rose with round junction plate 5Amp switches of recessed in wall using Modular plate & MS boxof required size, point taken upto D.B. duly tested and commissioned, etc. note: all items included like Conduit, Junction box, wire, box, switches, cutting the wall and making good the same etc.
Providing and fixing of UPS point (in loop max 5 pts.) with 1.5 sq. mm PVC insulated copper wire , through PVC Conduit pipe with all necessary accessories i/c 6Amp switches, 5 Amp 3-pin socket 1 nos. recessed in wall covered with Modular Plates i/c Modular Box & MS boxof required size i/c 1.5 sq.mm PVC Insulated copper wire of FRLS as earth wire, Point taken up to DB duly tested and commissioned note: all items included like Conduit, wire, box, switches, cutting the wall and making good the same etc.
Providing and fixing of Ac points using 6 sq mm PVC FRLS insulated copper wire through 1 inch heavy duty PVC conduit pipe and providing and fixing of 32 Amp Dp MCB 10KA C curve with enclosure including providing and fixing of 6 sq. mm PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned in all respects complete. note: all items included like Conduit, wire, box, switches, cutting the wall and making good the same etc.
Providing, fixing LED slim 15 watt 230V Downlighter Recessed/ Surface mount including MS box of required size as per requirement, complete in all respects not less than 100 LM/W LM79-80, L70 2KV Surge Protection
Providing, fixing LED slim 20 Watt T5 230 V 50 HZ.
Providing and fixing of 48 inches Sweep energy efficient ceiling fan of approved sample at site including wiring the down rods of standard length (30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc including Fan Junction MS box as required.
Providing and fixing of 24 inches Sweep energy efficient wall fan of approved sample at site including wiring complete in all respects
supplying, fixing of MS fan extension rod with holes, nuts, bolts etc as required 2 ft length with fan holding hook arrangements as per site requirement.
Providing and fixing of Fan dimmer electronic regulator Including MS box and Modular Plate 5Ampere 3 pin type.
Supplying and fixing of following sizes of heavyduty class conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 20 mm.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Dismantaling of old electric wiring of the site as required.
4 Module (125mmX75mm)
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtrs long 80 mm dia of outer shell (MS) with the 50 mm dia of inner shell (MS) of 80-100 microns galvanized CHEMRODE filled with highly conducting metallic compounds with the permenant sealings at both the ends with the lead terminal of 50x10mm size at the top. The electrode shall be duly tested and certified by CPRI (Central Power Research Institute), Govt of India for a peak short circuit withstanding capacity of 60 KA. including Supply/ fixing of environment friendly rust proof heavy duty weather proof polyplastic earth pit chamber.
Supplying and laying 25 mm x 5 mm G.I. strip at 0.50m. below ground level as strip earth electrode, including soldering etc. as required.
R.R. Builders
M/S WANI ELECTRIC AND MECHANICAL ENGINEERS
M/S SF ELECTRICALS
stage.html
html • 0.02 MB
finance_396893.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .