Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 LAccepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹6.1 L+₹1,835 (0.30%)Rejected-Finance 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹8.8 L+₹2.8 L (45.6%)Rejected-Finance | L3 | Rejected-Finance Not L1 |
Tender Value
₹8.4 L
EMD Value
₹16,900
Closing Date
14 Mar 2022, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-II Shah(S)
OFFICE OF THE Ex. ENGINEER (ELECT)-II 2 nd Floor Technical Laboratory Near NH-24 Ghazipur Delhi
Provision of lighting arrangement in park near kala niketan school Ghazipur village in ward 19E under shahdara south zone
2022_EDMC_108848_1
EE (Elect)-II//2021-22/45.2
Open Tender
Electrical Works
Item Rate
90 days
work
Please refer to tender documents
5 documents required · 5 mandatory
₹500
₹16,900
Yes
31 Jan 2024
7 Mar 2022
15 Mar 2022
7 Mar 2022
14 Mar 2022
7 Mar 2022
120 days
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.upto 35 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required.upto 35 sqmm
supply of XLPE PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098(Part-I) of following sizes:4 x 25 sq.mm
2 x 10 sq.mm
S & L of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.
Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized not be less than 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos luminaries symmetrically And its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4)shallow foundation of size 1m(L) x 1m wide and 2m deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bar of 12 mm dia - 2100mm(approx.) - 16 nos and reinforcement of cold twisted bar of 8mm dia - 3700mm (approx.) -13 nos. (with 150mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c 4 Nos S.P MCB, 63Amp. DPIsolator etc as reqd. logo/Name of manufacturer shall be embossed onits pole galvanised as per relevent IS.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
SITC of Pillar box size 900 mm x 450mm x 250mm suitable for mounting in comer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eleethoypic grade Aluminium ba bar of size 25mm x 10mm mounted on galvanized M. S. body power quoted pillerage proof SMC door duly welded with S.S. with rain com size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below grand and covered with shode proof SMC sheet of 3 mm as requred.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker single pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
SITC of 150W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd... (a) Total system wattage =150watt +/- 5% b) Luminaire Efficacy>=100 Lm/w c) Power Factor>=0.95 d) Protection IP-66
G D Electricals
M/s Tyagi Electric and Trading Co.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .