REPAIR/ MAINT TO HT OH LINES, TRANSFORMERS, VCBs AND MISC WORKS AT KARU AND SHESHARSHANTHANG AREA UNDER GE 860 EWS
2021_MES_473909_1
138WE/L-62/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 860 EWS
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 860 EWS
₹70,000
Yes
28 Oct 2021
8 Sept 2021
13 Oct 2021
8 Sept 2021
6 Oct 2021
22 Sept 2021
60 days
Amount
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, hard/dense soil, complete all as specified and directed
Excavation in trenches not exceeding 1.5 m wide exe 1.5m and n.exe 3m depth or part there of in depth beyond the first 1.5m complete all as specified and directed by Engr-in-Charge.
Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed .
Removing excavated soil to a distance n exc 50m and depositing at a level n exc 1.5m above the starting point in any type of soil complete all as specified and directed .
Material and labour for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles/stay assy including use of necessary form works for rough finished surface complete all as spd.
Material and labour for PCC 1:3:6 type C–2 (using 40 mm crushed graded stone aggregate)as in foundation of poles/stay assy ncluding use of necessary form works for rough finished surface complete all as spd.
Material and labour for PCC 1:2:4 type B–2 (using 40 mm crushed graded stone aggregate)as in COPING for poles including use of necessary form works for rough finished surface complete all as spd.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified in clause 19.75 of SSR PART-1 and directed Note: Punned thickness shall be measured.
Supplying and laying un-reinforced precast concrete cable cover, Class HV Type-II, flat, size 300mm x 180mm x 40mm, complete all as specified and directed
Supplying and laying of galvanised iron pipe of dia 80mm light grade with all fittings fixed on wall and ceilings or laid in floors/trenches/on poles for cable protection complete all as specified and directed by engineer in charge
Dismantaling of Unserviceable/HT Insulators (pin/shackle/Dice&loop) type from existing OH lines complete all as specified and directed by engineer in charge
S&F in replacement of polymer compisite Pin insulator, grey in colour, dia of FRP rod 20mm, length of FRP rod (min) 165mm, dia of weather sheds 100mm as per IEC 61109 for 11000 Volts grade complete all as specified and directed by engineer in charge
S&F in replacement of polymer compisite disc type grey in colour for working pressure 11000 Volts grade complete all as specified and directed by engineer in charge
M&L for dehydration of transformer oil with mobile transformer filtration plant at site with all required accessories connected to transformer and carring out filtration of transformer oil for the desired dielectric strength ie not less than 30kV at 2.5mm gap all as directed by engineer in charge Note:- test certificate shall be submitted before and after filteration for di electric strength
Supply and filling transformer oil of good quality for topping up transformer 200kVA to 630kVA capacity having dielectric strength not less than 50kV, Flashpoint not less than 135 degree centigrade having low viscosity for filling or replacing the old oil complete all as specified and directed by engineer in charge
M&L for shifiting of 315kVA/100kVA outdoor type transformer from GE 860 to div power house, TBS to GE 860 and placed on the platform make through this contract and 11 kV on HT side, 433 Volts, 3phase and four wire on LT side complete with electrical connection on HT < side including all the accessories/fittings and all as specified and directed by engineer in charge
Dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc
Supply and Install Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS-9921 Part-I to V(1982 to 1985) of 1972, rated voltage 11 KV and for current rating 400 Amp including taking out existing unservicable complete all as specified.
S&F danger notice plate of 1.6mm thick mild steel sheet , vitreous enamelled white ,with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps,bolts,nuts of approved size for HT, 25x20cm size including dismantling the Existing Damaged Danger Notice plate from the HT Poles keeping away from site all as directed.
Material and Labour for cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and as directed.
Material and Labour for cable Jointing Kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed.
M&L for steel swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 meters long) complete all as specified and directed by engineer in charge
S&F in replacement of stay assembly set comprising of 14mm long Stay bow, 2150mm long stay rod 20mm dia with threaded end GI nut bolt and washers, thimble including 300x300x6mm MS stay plate and exposed surface shall be given two coat of aluminium paint over a coat of red oxide primer complete including dismantling of existing damaged assembly complete with all accessories as shown in electrical plate No.1 of MES schedule Part-I and as directed.( Excavation, earthwork,Pcc & insulator shall be measured and paid seperately)
Supply, fabrication & fixing of cross arms, any type bracings, supports, clamps and back plates fabricated from structural steel sections made out of Fe-0-310/Fe-0-410 including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed complete and duly painted with one coat of PRIMER and two coats of aluminium paint complete all as specified.
Supply and Laying XLPE Insulated, Screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty with aluminium conductor, 11000 Volts (Earthed) grade cross sectional area 185 Sqmm 3 Core conforming to IS 7098 Part-II Suitable for earthed System complete all as specified and as directed. Note:- The end termination joint shall be measured and paid seperately under respective item ( Excavation, earthwork,Sand cushioning & protection cover shall be measured and paid seperately)
Supply and Laying XLPE Insulated, Screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables, heavy duty with aluminium conductor, 11000 Volts (Earthed) grade cross sectional area 95 Sqmm 3 Core conforming to IS 7098 Part-II Suitable for earthed System complete all as specified and as directed. Note:- The end termination joint shall be measured and paid seperately under respective item ( Excavation, earthwork,Sand cushioning & protection cover shall be measured and paid seperately)
M&L for ACSR couductor any size drawn stright, horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured stright horizontal distance between center of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers, (a) 1of 6/1x3.00mm(Ferret) etc complete all as specified and directed by engineer in charge
Opening of the VCB, 11Kv 630/400Amps by removing of the breaker from the existing position after disconnecting all the connection from the system, servicing, overhauling of the same, checking of the same for proper operation, spring charge, charged control cables are fastened tightly to the terminals, any abnormality, VCB, cleaning the surface of the insulator, fasten the bolts, checking and orrecting interrupting units, mechanism, linkages etc, fasten the hardwares of control wiring, check that the split pins, circleclips, dowell pins etc have not come out and are intact, lubricate the mechanism, moving parts by castrol, all purpose grease or equivalent, check that the vaccum pots/chambers is within limit including opening of the sahutters properly, replacing of the trip catch, roller, holding catch, stopper, close push button, closing cum reasembling, control limit switches reconnecting of the breaker for smooth functioning all as directed
Decarbunizing/cleaning complete HT 11kV, 3 Phase independent bus bar, bus bar chamber of HT panel electrification connection complete, HT VCB switch gear arragnement incoming and outgoing installed in sub station after removing the complete bus bar spout, circuit spout from the bas bar chamber, cleaning with CTC and ensure proper decarbunising ,refixing the same after applying Backtol (Red) solution to the spout, checking all the connection, tightening the nuts, bolts, thimbles for incoming and outgoing system complete, replacemet of the damaged space heater along with thermostats, door/position limit switches, control fuse and servicing/greasing to manual charging/spring charging mechanism line Cts PTs and replacement of the damaged PT fuseall as specified and directed, rate quoted is inclusive of bactol (Red), CTC & cotton waste provided by contractor
Supply and fixing in repalcement of only closing coil assembly 110V Dc for VCB all as specified and directed
Supply and fixing in repalcement of only tripping coil assembly 110V Dc for VCB all as specified and directed
Supply and fixing in repalcement of only 11kV PT HV backup fuse complete all as specified and directed by engineer in charge
M&L for replacing existing unservicable silica jel with new crystal clean silica jel for the breathers of transformers capacity 50 to 630 KVA all as specified and directed by engineer in charge.
Supply and fix in replacement of unserviceable (broken/cracked) breathers assy complete of various transformer suitable for pipe entry of 20/25 mm dia all as specified and directed by engineer in charge.
Supply and fix in replacement of oil temperature gauge complete all as specified and directed by Engineering-in- Charge
M&L for taking down transformer oil level indicator assembely of various transformer from position for making visiability of oil level after draining transformer oil by lowering oil level in conservator, with and including cleaning, painting, changing of gasket and acrylic sheet, fixing back in position complete all as specified and directed by Engineering-in-charge
M&L for replacing existing unservicable drain valve suitable size of various transformers complete all as specified and directed by engineer in charge
Supply and fix in replacement of only explosive vent diapharm complete all as specified and directed by engineer in charge
M&L for painting of transformer 11kV/415 Volte (63kVA to 630 kVA) outdoor/indoor/pole mounting including cleaning, scraping of exposed surface and painting two coat of synthetic enamel paint over a coat of primer with shade as approved including writing MES Nos and machine No with black paint, size of letter shall be 15mm wide and 50mm high complete all as specified and directed by engineer in charge
Disconnecting the transformer any type situated at various location 11/433kV of any make and transporting to workshop for repair/rewinding. Dismantaling the transformer and accessories, draining out insulating oil, taking out the core assembly, defective winding, cleaning the transformer complete internally and externally, rewinding burnt HT/LT coil with existing guage of copper super enamelled wire/copperstrip of existing size, providing new insulation, sleeves for outlet connection ovening the complete core assembly, ressembiling, including dehydration and filtration and filtration of transformer oil to achive desired dielectric strength, carryingout routine test, reinstallation and commissioning. the repair work also includes the routine test ie IR value, high voltage test, ratio test, short circuit test and BD value of oil of transformer to be carried out at work shop for following capacites of transformer above 63kVA to 400kVA Notes:- (i) copper winding wire/strip will be measured and paid seperately (ii) Transformer oil will be measured and paid seperately (iii)Transportation of transformer for repair and reinstallation is deemed to include in quoted rates complete all as specified by engineer in charge.
Removal of burnt HT coil winding and replacement of the same with new copper wire coil of same guage and turns including necessary insulation materials of transformers of capacites 63kVA to 400kVA complete all as specified and directed by Engr-in-charge.
Removal of burnt LT coil winding and replacement of the same with new copper strip of same guage and turns including necessary insulation materials of transformers of capacites 63kVA to 400kVA complete all as specified and directed by engineer in charge
Disconnecting the transformer any type from HT/LT system and opening carefully for rectifying the leakage by replacing the unserviceable spare parts of capacity 63kVA to 400kVA transformer and complete assembling after repairs including testing for any oil leakages, proper functioning and connecting the LT/HT system complete all as specified and directed by engineer in charge
Supply & Fixing in replacement of Anti-climbing device spike type fabricated out of MS bars (round, square and flat) including nuts, bolts and washers and welding into two halves made to shape to suit the cross section of the pole.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr. Below ground level connecting to galvanised iron strip 32x6mm as earth lead by means of bolts, check nuts and washers of GI and earth strip protected by provision of GI pipe light grade, 40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM ( weight not less than 4Kg/Sqm) and frame of angle iron 40 x 40 x 6mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as shown in electrical plate No 5 of MES SSR Part-I and connection to MCB DB's eart test point all as specified and testing on completion all as specified and directed. .
S&F in replacement of MS chequred plate cover 10mm thickness for cable duct including two coat of synthetic enamel paint over a coat of red oxide primer complete all as spd and directed
osho traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .