Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹2.4 L
Closing Date
18 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
SDSTE/ALJN
17 conditions · 6 needing a document upload
10.2. Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet. ( Click here to download Format)
Balance Sheet Declaration- Balance sheet for the 4th previous year (i.e. FY 2021- 22 or as applicable) as per para 10.2 of GCC-2022 shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annex- VI B or a self declared certificate as attached duly signed by chartered accountant and the tenderer that the balance sheet of last financial year (i.e. FY 2024-25 or as applicable) has not been audited/yet to be prepared. If, balance sheet of last financial year (i.e. FY 2024-25 or as applicable) audited/ prepared then NIL position to be uploaded. ( Click here to download Format)
10.1 Technical Eligibility Criteria: (a)The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(i): Separate completed works of minimum required values for each component shall also be considered for fulfilment of technical eligibility criteria. (b) (ii) In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 (a) (ii) of Part-II of GCC or through subcontractor fulfilling the requirements as per clause 7 of Part-II of GCC or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing However, if required in tender documents by way of Special Conditions, a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of GCC, with prior approval of Chief Engineer in writing.
Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components.(b)(2)In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of similar work:-"Any Signalling Work."
Bidder has to upload requisite information as per Annexure V(A) along with the offer.
43 conditions · 4 needing a document upload
Stamp Duty fee for Bank Guarantee (for bid security) should be paid which should be 0.5% of the Bid security or Rs.10,000/-, whichever is less or as per latest/revised state policy of UP state.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) /registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate.(Note:In case of non-submission of above documents, offer may be summarily rejected)
The tenderer will give full information ( in annexure-A) as to the date of retirement of such Engineer or gazetted officer from the said service and as to whether permission for taking such contract, or if the Contractor be a partnership firm or an incorporated company, to become a partner or director as the case may be, has been obtained by the tenderer or the Engineer or officer, as the case may be from the President of India or any officer, duly authorized by him in this behalf, shall be clearly stated in writing at the time of submitting the tender,if a tenderer is - i) be a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, whether in the executive or administrative capacity or whether holding a pensionable post or not, in the Engineering or any other department of any of the railways owned and administered by the President of India for the time being, OR ii) being partnership firm / joint venture (JV) / registered society / registered trust etc have as one of its partners/members a retired Engineer of the gazetted rank or any other gazetted officer working before his retirement, OR iii) being an incorporated company have any such retired Engineer of the gazetted rank or any other gazetted officer working before his retirement as one of its directors AND in case where such Engineer or officer had not retired from government service at least 1 year prior to the date of submission of the tender
If a tenderer or Contractor being an individual, have member(s) of his family or in the case of partnership firm/ company / joint venture (JV) / registered society / registered trust etc. one or more of his partner(s)/shareholder(s) or member(s) of the family of partner(s)/shareholder(s) having share of more than 1% in the tendering entity employed in gazetted capacity in the Engineering or any other department of the railway, then the tenderer at the time of submission of tender, will inform the authority inviting tenders the details of such persons. ( in annexure-A)
An undertaking shall be submitted by sole proprietorship firm, HUF, JV, LLP, Company registered under companies Act 2013 that he/they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of opening of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (Note: Each member must sign separately in case of JV/Partnership firm/LLP.).(Note: IN case of non submission of above documents, offer may be summarily rejected).
In case of partnership firm an undertaking shall be submitted by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm in which they were / are partners. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the General Conditions of Contract. (Note: In case of non- submission of above documents, offer may be summarily rejected)
Please submit your bank details i.e.Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Whether the cost of tender form is submitted in hard copy if uploaded as a scanned copy in website.
Whether the cost of Bid Security is submitted in hard copy if uploaded as a scanned copy in website.
16.(1) Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfilment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
16.(4) Performance Guarantee:- The procedure for obtaining Performance Guarantee is outlined below: (a)The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty-one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty-one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty-one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work.
(b)The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value: - (i)A deposit of Cash; (ii)Irrevocable Bank Guarantee; (iii)Government Securities including State Loan Bonds at 5% below the market value; (iv)Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v)Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi)Deposit in the Post Office Saving Bank; (vii)Deposit in the National Savings Certificates; (viii)Twelve years National Defence Certificates; (ix)Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted. (c)The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d)The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e)The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f)Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g)The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i)Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii)Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii)The Contract being determined or rescinded under clause 62 of these conditions.
Balance sheet for the 4th previous year (i.e. FY 2021-22 or as applicable for the instance tender) as per para 10.2 of GCC-2022 shall be considered in evaluation of financial eligibility criteria only when it is clearly certified in Annex- VI B or a self declared certificate duly signed by chartered accountant and the tenderer that the balance sheet of last financial year (i.e. FY 2024-25 or as applicable for the instance tender) has not been audited/yet to be prepared.
All Rules of NIT & Post LOA shall be governed by GCC & tenderer agree to adhere to it without any dispute.
Old GCC has been changed and replaced with new General Conditions of Contract-2022, which has been added in tender document. Please go through this new General Condition of Contract-2022 along with all advanced correction slips before bidding. In case of any discrepancy, contradiction with regard to GCC (except special condition of contract) in that case GCC- 2022 will be applicable.
Interlocking of 03 nos. (LC-24, LC-35 & LC-8HK) mid-section non interlocked LC Gates in branch lines over Prayagraj division.
PRYJ-SIG-429-2025-26
PRYJ-SIG-429-2025-26
Open
Works - General
12 Months
Prayagraj, Uttar Pradesh
₹0
₹2.4 L
18 Mar 2026
23 Feb 2026
4 Mar 2026
163 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,86,40,815.79 | ||
| — | 3.00 | — | — | ||
| Supply, wiring, installation and commissioning of Earth Leakage Detector (ELD) having 6 digit counter, 12 Channel bus bar, voltage of 110V/60V/ 24V/12V inAC/DC measurement as per RDSO Spec.No. RDSO/SPN/256/ 2002 or latest. This includes supply of fuse terminal strip for incoming power supply wires. Installation to be done on 19 inch sub rack along with insulation resistance meter, remote indication and buzzer in ASM room. (Insp. By RDSO) | — | — | — | 5,73,766.68 | |
| — | 3.00 | — | — | ||
| Supply of Micro Processor based Remote Terminal Unit (RTU) with 128 digitalinput & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest.It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply upto RTU. Itincludes supply of relay room door lock checking arrangement, commercial powersupply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, interlinking and networking of RTU. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines. (Insp. By RDSO) | — | — | — | 7,80,534.75 | |
| — | 3.00 | — | — | ||
| Installation, testing and commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input and 16 analog input as per RDSO Spec.No. IRS (S) 99/2006 (Amdt. 3) or latest . It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply upto RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, interlinking and networking of RTU. It also includes installation of leased line MODEM and other interfacing cards, if required for networking of RTU. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines. (Insp. By Consignee) | — | — | — | 1,22,014.62 | |
| — | 3.00 | — | — | ||
| (a) Design, preparation and supply of the following Technical documents:(i) Installation, Testing, Commissioning and Maintenance manuals. (ii) Functioning and System overview manuals. (b) Design, preparation and supply of the following the following completion documents: (i) Application Logic circuits. (ii) VDU/CCIP/LCP diagram. (iii) Interface Circuit/Wiring diagrams consisting of Relay contact analysis chart, Relay disposition chart, Relay contact to contact wire list chart, LCP/VDU/CCIP cable termination chart, Power supply diagram, Electronic signalling equipment and Power supply layout diagram, Relay rack and Cable termination rack layout diagram, Relay rack and Cable termination rack particulars, Fuse, Resistors, Condensors etc. particulars, Details of Analog and digital inputs to be supplied to Data logger, Block wiring diagram (if applicable), Wiring diagrams for SSDAC or HASSDAC or MSDAC or BPAC (if applicable). (iv) Cable Route plan with overlaid Location Boxes placement (As per NCR HQ Drg. No. TYP/14/0017 issued vide letter no. S&T/NCR/DRG/TYP dtd 29.12.2014). (v) Cable Core plan with overlaid Location box placement. (vi) Location huts/Goomties wiring diagrams (if applicable). (vii) Location boxes wiring diagrams. (viii) Track circuit bonding plan. (ix) Earthing particulars plan. (x) Signal Interlocking plan (SIP). (xi) Station working rule diagram (SWRD). (xii) Station working rule (SWR). (xiii) Selection table/ Route control chart. (Xiv) Necessary corrections in data logger documents. All the above completion documents should be supplied as follows: (i) Two sets initially for approval and commencement of work (ii) One set in soft copy (in editable AUTOCAD format) in Pen drive. (iii) One set of Original tracings (iv) Six sets of final 'As Made' completion plans/diagrams in proper bounded form. (Insp. By Consignee) | — | — | — | 5,22,369.6 | |
| — | 2.00 | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines & TAN. It includes: Design and modification in existing Interface, Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/ LCP (Local Control panel), CCIP (Control cum Indication Panel) if any, Maintenance terminal (MTPC), Data Logger, Relay rack wiring etc. The complete work should comply with the latest RDSO specifications, guidelines and as per approved SIP & circuit diagrams. All the material (Interface cards/ relays/wiring material/ connectors/ fuses /communication devices etc.) shall be provided by the contractor. The work includes the supply of modified Selection table, Interface Circuits, VDU/LCP,Data Logger & CCIP diagram if any etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT or two rounds FAT (as applicable) jointly with Railways and satisfactory commissioning. All plans / drawings/circuits etc. should be prepared on Auto CAD. Soft copy including Auto CAD copy has to be supplied in pen drive and 06 sets of hard copies also to be supplied as a completion drawing. (A )Alteration involving modification in up to 10 routes. (Insp. By Consignee) | — | — | — | 36,56,562 | |
| — | 15000.00 | — | — | ||
| Supply of 16/0.2 mm (0.5 sq mm) PVC insulated multi strand, single core, tinned copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire will be specified by the Engineer incharge. (Insp. By Consignee) | — | — | — | 1,61,250 | |
| — | 3000.00 | — | — | ||
| Supply of PVC Insulated, Indoor cable, single core, 1.0 mm, flexible, as per IRS-S-76/89 (Amndt.-3) or latest. Coil should be of different colours, each in 100 m length. (Insp. By Consignee) | — | — | — | 22,410 | |
| — | 3000.00 | — | — | ||
| Supply of 1 x 6 Sq mm (Red/Black/Green) multi strand copper power wire , 85 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89 (Amnd.3) or latest.Colour of the wire will be specified by the Engineer incharge. (Insp. By Consignee) | — | — | — | 1,44,000 | |
| — | 1500.00 | — | — | ||
| Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Insp. By Consignee) | — | — | — | 1,98,690 | |
| — | 1500.00 | — | — | ||
| Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge.(Insp. By Consignee) | — | — | — | 2,21,805 | |
| — | 1500.00 | — | — | ||
| Supply of 1 x 25 Sqmm (Red/Black/Green) multi strand pvc insulated copper flexible power wire, and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. (Insp. By Consignee) | — | — | — | 6,13,125 | |
| — | 90.00 | — | — | ||
| Supply of PPTC fuse GP 250-185, UL-94 certification (24 V/ 4 Amp) 110V AC for Track Chargers. Make Fuzetec, Tyco, Raychem, Little fuse or similar. (Insp. By Consignee) | — | — | — | 754.2 | |
| — | 6.00 | — | — | ||
| Supply of Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized, metal to metal, with different ward combinations and contact configuration 4F/4B with 2 extra ward plates, RDSO spec no. RDSO/SPN/219/2016 Ver 1.0 with Amendment-1 or latest. (Insp. By Consignee) | — | — | — | 48,139.08 | |
| — | 6.00 | — | — | ||
| Supply and installation of prewired KLCR Box, wooden crank handle lock inside box, with 8 way terminal strips, LEDs of approved type, for fixing of EKT on wooden board inside box form installating KLCRs/EKTs up to 06 no., including supply of all material like board, handle, hinges, glass sheet etc. (Insp. By Consignee) | — | — | — | 80,154.72 | |
| — | 3.00 | — | — | ||
| Supply of Electrically Operated Lifting Barrier complete set suitable for 110VDC/110VAC / 24V DC supply, without hand generator back up, and motorized boom locking arrangements as per RDSO Spec.SPN/208/2012 Ver. 2.0 or latest. The 02 Nos of Barriers of length 09.76 Mtr. should be supplied along with stop boards and light. The spares & tool kit mentioned in RDSO Spec. no. RDSO/SPN/208/2012 Ver. 2.0 and Amndt. 1 or latest, clause 10.1 & 10.2 reproduced as below should be supplied along with each full set: - (i) GI boom - 1 no. complete. (ii) Belt - 1 no. (iii) Crank handle - 1 no. (iv) Motor Contactor - 1 no. (v) Motor protection MCB- 1 no. (vi) Push button complete- 2 nos. (vii) Limit switch - 3 nos. (1 lever type and 2 top roller type) (viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier. (Insp. By RDSO) | — | — | — | 11,37,479.25 | |
| — | 3.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc. (Insp. By Consignee) | — | — | — | 1,66,989.78 | |
| — | 4.00 | — | — | ||
| Supply, Installation,testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per GZB Workshop drawing no. SA-SWG/GZB/E/01. The sliding boom assembly should be have the provision of 50mmx50mmx50mm angles for the entire length. Boom rest posts should be 10 no per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of Sliding LC gate. (Insp. By Consignee) | — | — | — | 6,88,257.16 | |
| — | 3.00 | — | — | ||
| Supply, installation, testing and commissioning of LED type control cum indication panel complete with prewired Tag- Blocks, Wires MS angles etc. for LC gate , depicting the yard layout Signal, Point, Track circuit, Operating / emergency Push Button, counter with sealing arrangements, house in a Steel metal cabinet. This shall be consist 15 x 10 exchangeable Domino Unit as per Spec. SPN/186/2004 Rev. 2.0 or latest. The indoor wiring inside panel shall be terminated on tag block as per instructions of Engineer-in-charge. The wiring on panel tag blocks shall be repeated on tag blocks located in relay room. This includes laying & termination of cable, if any from Panel Room to Relay Room in HDPE pipe. (Insp. By Consignee.) | — | — | — | 1,92,213.9 | |
| — | 3.00 | — | — | ||
| Supply and installation of Cable Termination (CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8- way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant and powder coated. (Insp. By Consignee) | — | — | — | 1,41,440.52 | |
| — | 45.00 | — | — | ||
| Q-Series LED ECR (Universal Type i.e.QECX-61), 4F/4B complete with plug board(base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 ,Amdt.-1 or latest and RDSO Spec.No.IRS:S@ 45"44@ S-23 or latest, as applicable.The interlocking code for this unit shall be "ABDHK". (Insp. By RDSO) | — | — | — | 3,11,282.1 | |
| — | 90.00 | — | — | ||
| Q-Series Neutral Line Relay, non-AC immunised, (QN1 Type), 8F/8B, 24V DC complete with plug board(base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 ,S-23, S-60 or latest, as applicable. The interlocking code for this unit shall be "ABCDF". (Insp. By RDSO) | — | — | — | 3,27,546.9 | |
| — | 36.00 | — | — | ||
| Q-Series Line Relay (QNA1 Type),AC immunized, 8F/8B, 24 V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@ 45"44@ S- 23 , S-60 or latest, as applicable. The interlocking code for this unit shall be "ABDGH". (Insp. By RDSO) | — | — | — | 1,59,812.64 | |
| — | 6.00 | — | — | ||
| Fail Safe Electronic Flasher device, 24V DC or 60 V DC, as per RDSO spec. RDSO/SPN/173/2002, Amdt.2 or latest. (Insp. By RDSO) | — | — | — | 67,528.62 | |
| — | 15000.00 | — | — | ||
| Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2 m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done. (Insp. By Consignee) | — | — | — | 9,70,350 | |
| — | 300.00 | — | — | ||
| Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. (Insp. By Consignee) | — | — | — | 3,08,712 | |
| — | 30.00 | — | — | ||
| Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. (Insp. By RITES) | — | — | — | 8,24,994.3 | |
| — | 30.00 | — | — | ||
| Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full ( As per drg no. AGC/FULL LOC/ 2023/01 issued vide NCR letter no. NCR/S&T/8005/TYPICAL/PT-4 Dt.14.08.2025 or latest ) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder , switch and lamp etc. in Apparatus Case. (Insp. By Consignee) | — | — | — | 3,68,166.6 | |
| — | 30.00 | — | — | ||
| Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fi xtures like ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fi xing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. Th e iron angle for fi xing shall be minimum 3 mm thick. Th is also includes fi xing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. Th e work shall be done as per instructions of Rly engineer at site. (Apparatus case Full) (Insp. By Consignee) | — | — | — | 1,34,293.2 | |
| — | 600.00 | — | — | ||
| Supply of Disconnect Terminal block for four conductors with screwing cage/clamp type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate lenght of rails for fitting terminal blocks. (Insp. By Consignee) | — | — | — | 1,15,632 | |
| — | 60.00 | — | — | ||
| Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest. (Insp. By RDSO) | — | — | — | 14,613 | |
| — | 60.00 | — | — | ||
| Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S -78/92 with latest amendments, 2A/4A/6A/8A/10A rating capacity. (Insp. By RDSO) | — | — | — | 7,388.4 | |
| — | 3000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. (Insp. By Consignee) | — | — | — | 44,280 | |
| — | 600.00 | — | — | ||
| Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. (Insp. By RDSO) | — | — | — | 70,206 | |
| — | 600.00 | — | — | ||
| Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately). (Insp. By Consignee) | — | — | — | 10,578 | |
| — | 3.00 | — | — | ||
| Provision of Ring Earth for EI system, consisting of 06(six) number of maintenance free earths, which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement materials, earth pit, equipotential earth bus bar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. RDSO/SPN/197 Ver.1.0 or latest and provision of earth pits to be connected in a ring to achieve less than 01(One) ohm earth resistance for connecting EI quipments, relay racks, panel , power equipments as per RDSO TAN no. STS/E/TAN/3006 dated 02.11.2012. Diagram of ring earth should be supplied to Railway for approval before execution. All related materials as recommended by RDSO in Spec. No. RDSO/SPN/197 Ver. 1.0 or latest, will be supplied by the contractor. Note: If due to site ondition (high soil resistivity, larger size of EI room etc.) more than six maintenance free earths are required then the rate of payment for each such extra individual earth shall be done as per the rates of SOR items 13002 and 13003 (Earthing Items SOR). No other payment for any other material/accessory/fixture etc. shall be admissible for such extra maintenance free earths. (Insp. By RDSO) | — | — | — | 5,00,138.88 | |
| — | 3.00 | — | — | ||
| Supply, Installation and commissioning of active lightning arrestor of Class 'A' for building protection as per standard NFC-17-102 :2011 or latest. It shall work on early streamer emission principle. It shall be made of stainless steel with an operating time of 60 microsecond or less. A non-resettable counter shall be provided to count the number of lightning occurrences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding. (Insp. By Consignee) | — | — | — | 3,35,155.08 | |
| — | 45.00 | — | — | ||
| Supply and installation of earth electrode as per standard practice and as per NCR Drawing No. S&T/CONST/6.4/97. It includes supply of GI pipe of 3 meter length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter deep and fi xing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per drawing No. S&T/CONST/6.3/97. It includes installation of 7 strand GI wires as earth lead wires, supported on MS fl at size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS fl at to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Insp. By Consignee) | — | — | — | 1,50,909.3 | |
| — | 24.00 | — | — | ||
| Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit. (Insp. By RITES) | — | — | — | 6,06,568.32 | |
| — | 24.00 | — | — | ||
| Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer. (Insp. By Consignee) | — | — | — | 10,890.24 | |
| — | 24.00 | — | — | ||
| Supply of Offset brackets for Main Signal, made of Mild Steel, outer diameter 140 mm (5.5 inch), thickness of pipe 4.5 mm with fixing arrangement on Main Signal post as per Drawing No SA- 23080/Adv. along with fixing U bolts, nut and clamps. (Insp. By Consignee) | — | — | — | 28,958.16 | |
| — | 12.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No.RDSO/SPN /151/1997 or latest. (Insp. By Consignee) | — | — | — | 3,75,696.96 | |
| — | 12.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO / SPN / 151 /1997 or latest. (Insp. By Consignee) | — | — | — | 4,28,848.44 | |
| — | 24.00 | — | — | ||
| Casting, concreting and curing of foundation for Main Signal Post in the ratio of 1:3:6 as per IRSEM Drg no. - 19-D-3, using standard size of foundation/galvanized anchor bolts complete, required for erection of colour light signal post. Anchor bolts complete should comply with the RDSO drg. no. SA 116 A/M. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. (Insp. By Consignee) | — | — | — | 3,24,150.72 | |
| — | 24.00 | — | — | ||
| Erection of CLS Post with base and signal unit on top or on Offset signal if any. It includes fixing of all LEDs and wiring of complete signal including route and auxiliary signals, if any. It includes fixing of front and back staging, ladder and guards, signal name plates /boards, with contractor's own brackets and fixing materials. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. Bracket including erection of auxiliary signals like calling on, shunt. (Insp. By Consignee) | — | — | — | 1,41,089.76 | |
| — | 30.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full). (Insp. By Consignee) | — | — | — | 20,197.5 | |
| — | 24.00 | — | — | ||
| Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar. (Main Signal post, base, unit and complete fittings). (Insp. By Consignee) | — | — | — | 22,356 | |
| — | 60.00 | — | — | ||
| Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit. (Insp. By Consignee) | — | — | — | 5,016.6 | |
| — | 150.00 | — | — | ||
| Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. Th e GI pipe is to be fi lled with chattered compound. It includes supply of all material required for fi xing arrangement. Contractor will also supply fl exible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Th e laying and fi xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. (Insp. By Consignee) | — | — | — | 54,229.5 | |
| — | 31500.00 | — | — | ||
| Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. (Insp. By Consignee) | — | — | — | 2,15,460 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Microprocessor based Networkable analog addressable and modular type of fire Alarm Control panel with display with 2 loop expandable up to four loop, power supply and battery backup as per RDSO specification no. RDSO/SPN/217/2021 ver. 3.0 or latest, including. GSM module-01 No. for sending SMS to configured mobile number and relay module-02 Nos. for connecting to data logger for remote Monitoring. The panel should support sufficient devices of both detectors and modules in a single line circuit. (Insp. By RDSO) | — | — | — | 2,93,178.24 | |
| — | 15.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Addressable heat & smoke Multi sensor. As per RDSO Specification No. RDSO /SPN/ 217 / 2021 Ver 3.0 or Latest). (Inspection of Supply portion BY RDSO and installation and commissioning Insp. By Consignee) | — | — | — | 45,802.65 | |
| — | 150.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of analog LHS cable (As per RDSO Spec No. RDSO/SPN/ 217/2021 Ver 3.0 or Latest). (Inspection of Supply portion BY RDSO and installation and commissioning Insp. By Consignee) | — | — | — | 1,76,121 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Analogue Addressable & resettable Manual Call Point with inbuilt short circuit fault isolator (as per RDSO /SPN/217/2021 Ver 3.0 or latest). (Inspection of Supply portion BY RDSO and installation and commissioning Insp. By Consignee) | — | — | — | 12,581.61 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of Hooter cum Strobe including its control module. (As per RDSO Specification No. RDSO/SPN/217/2021 Ver 3.0 or Latest). (Insp. By RDSO) | — | — | — | 7,245.24 | |
| — | 12.00 | — | — | ||
| Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI marked, with all accessories, operating temperature (-30)° to (50)° for class 13 B type of fi re with 1 meter long hose pipe fi tted with PVC bend horn, with carying handle and wall mounting brcket, complete in all respect. It should conform to IS 2878:2004. Extinguisher certificate has to be supplied along with the item. (Insp. By Consignee) | — | — | — | 60,603 | |
| — | 3.00 | — | — | ||
| Supply of Isolation transformer 10 KVA, input and output 230V AC 50 Hz Sine Wave Single phase. (Insp. By Consignee) | — | — | — | 2,30,035.5 | |
| — | 3.00 | — | — | ||
| Installation of Isolation transformer 10 KVA, input and output 230V AC 50 Hz Sine Wave Single phase. (Insp. By Consignee) | — | — | — | 9,940.02 | |
| — | 1500.00 | — | — | ||
| Loading, Transportation/Carriage and Unloading of various S&T material by a 9 MT truck, from/to the consignee depot to/from various locations, as decided by the Railways. (Insp. By Consignee) | — | — | — | 77,850 | |
| — | 3.00 | — | — | ||
| Supply of Desk type Electronic Magneto telephone as per spec. No. IRS TC: 79/2000 (Amndt.4) or latest. (Insp. By Consignee) | — | — | — | 10,572.54 | |
| — | 3.00 | — | — | ||
| Supply, installation and commissioning of complete Electronic LC Gate telephone system, (both master and slave), in 1+6 confi guration, with surge protection and power supply system and battery, as per RDSO spec.No. RDSO/SPN/TC/51/2021, Rev. 1.0 or latest. (with Voice logging facility). (Insp. By Consignee) | — | — | — | 2,35,997.94 | |
| — | 3.00 | — | — | ||
| Supply of Universal 2 wire/4 wire way station DTMF control Telephone, as per RDSO spec. no. IRS: TC:82:-2005, (with Amd. 3 or latest.). (Insp. By Consignee) | — | — | — | 15,595.35 | |
| — | 6.00 | — | — | ||
| Installation, testing and commissioning of 4 wire way station equipment with necessary mounting arrangement on standard 19"rack. It includes the supply of all wiring material such as casing, capping,10/20 pain indoor cable and wiring between way station equipment and termination box etc. (Insp. By Consignee) | — | — | — | 7,020.12 | |
| — | 6.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver. 1.0 or latest to achieve a resistance less than 1 ohm. It consists of following: (a) Copper bonded steel electrode of minimum 3.0 m long, minimum 17.0 mm dia with copper bonding thickness of minimum 250 microns and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate. (minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable. (Insp. By RDSO) | — | — | — | 1,08,255.12 | |
| — | 6.00 | — | — | ||
| Installation of Unit Maintenance Free Earth to achieve a resistance less than 1 ohm as supplied under item no. 13002 of Chapter 13 of SOR. It includes (i) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm dia and 3.00-meter-long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made irement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Spec. No. RDSO/SPN/ 197 Ver 1.0 or latest. Typical RDSO approved drawings referred in the RDSO specification document are: (i) SDO/RDSO/E&B/001 for typical installation of Earth. (ii)SDO/RDSO/E&B/002 for typical bonding and earthing connections, (iii) SDO/RDSO/E&B/003 for typical arrangement for earth resistance measurements. (Insp. By Consignee) | — | — | — | 43,159.02 | |
| — | 6.00 | — | — | ||
| Supply of Fuse auto changeover system for Railway Signaling System as per RDSO/SPN/209/2012 Rev.2 or latest for Relay room fuses up to 10 Ampere capacity for 2V/24V/60V/110V DC and 110V AC systems. The units shall be mounted on DIN rail in adequate size enclosure as per instructions of Railway site engineer. Two no. of O+NC contacts shall be provided for remote monitoring. The changeover time shall be less than 1 msec. The audio visual alarm for main and standby fuses shall be provided. One set means set of each fuse. (Insp. By RDSO) | — | — | — | 13,498.14 | |
| — | 6.00 | — | — | ||
| Installation wiring testing and commissioning of Fuse auto change over system. This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. One set means set of each fuse. (Insp. By Consignee) | — | — | — | 917.28 | |
| — | 30.00 | — | — | ||
| Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, coarse, sand and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). Th e aggregate cement and sand will be supplied by contractor. (Insp. By Consignee) | — | — | — | 1,48,961.4 | |
| — | 150.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Fire survival integrity cable 2C X 1.5 sqmm 500V rated (Unarmoured) as per RDSO/SPN/217/2021 Ver 3.0.or latest. (Insp. By RDSO) | — | — | — | 8,644.5 | |
| — | 18.00 | — | — | ||
| Supply, fabrication and fixing of Retro-reflective Signal number plates as per IRSEM DRG No. 19-D10 (Sheet 6&7 of 10) and NCR Drg. No. TYP/2024/006 - 011 on signal post with contractor's own material like clamp, U bolts, nuts etc.Technical specs for supply and installation as per annexure 1. (Insp. By Consignee) | — | — | — | 10,560.96 | |
| — | 18.00 | — | — | ||
| Supply, fabrication and fixing of retro-reflective marker/boards / plates as per the following: 'P' marker-Non illuminated as per IRSEM DRG No. 19-D10 (Sheet 5 of 10), 'AG' marker-Non illuminated as per IRSEM DRG No. 19-D10 (Sheet 2 of 10) , 'A' marker - Illuminated as per IRSEM DRG No. 19-D10 (Sheet 1 of 10), 'G' marker -Non illuminated as per IRSEM DRG No. 19-D10 (Sheet 3 of 10)or as applicable and provided by Railways. Technical specs for supply and installation as per annexure 1. (Insp. By Consignee) | — | — | — | 13,003.2 | |
| — | 3.00 | — | — | ||
| Installation , Tesing and Commissioning of Integrated Power Supply (IPS) equipments grounting, laddering, wiring and interconnection of Power Pannal, Power equipments, programme Switches, Bus Bars fited on relay Racks outgoing Supply terminals on CT racks. All the Power wire should be terminated with copper lugs and sholered with contractors own metrials. The IPS to be commissioned by the OEM. (Insp. By Consignee) | — | — | — | 1,07,811.93 | |
| — | 6.00 | — | — | ||
| Supply and installation of 25W gate hooter as per spec.no. SDH 25 Ahuja make and as per the instructions of Railway representative at site. It should be fitted inside MS sheet box of min 20 gauge on suitable post. (Insp. By Consignee) | — | — | — | 6,836.58 | |
| — | 6.00 | — | — | ||
| Supply and fixing of Amplifier Ahuja make PA-4005 or similar inside the gate lodge with suitable fixing arrangement as per instruction of site Engineer at site. Necessary power supply arrangement for the same to be provided by railways. (Insp. By Consignee) | — | — | — | 11,174.34 | |
| — | 3.00 | — | — | ||
| Supply & Erection of Relay rack, frame, scaffolding and ladder/angle for relay room, power equipment room, batteries room and other places as required, all oven baked and powder coated with Biscuit Mat colour corrosive resistant and final finish with Grey (Sigma) enamelled paint, complete as per drawing No. CSTE/ with fuse strip, anodized bars/strip for relay bases,Insulators, grouting bolts, tripods,rack fittings, ladder arrangement,all necessary fitting, supports,insulators, PVC slotted trunkin ghaving removable covers.Capacitors, resistors, diodesand other accessories etc. as per drawing and technical specifications & Erection of relay racks with scaffolding arrangement, suitable grounding arrangements, fixing of tag blocks on relay racks and complete all the accessories as per technical specifications. (Insp. By Consignee) | — | — | — | 81,972.63 | |
| — | 3.00 | — | — | ||
| Supply, Installation, Testing & Commissioning of Linear Heat Sensing Interface Module for Linear Heat Sensing cable/LHD interface module for LHD & with all other associated fittings as per RDS0/SPN/217/2021 Ver.3 or latest. (Insp. By RDSO) | — | — | — | 1,26,484.65 | |
| — | 150.00 | — | — | ||
| Copper Tape 25x2 mm for interconnection of earth electrodes as per RDSO Drawing SDO/RDSO/E&B/001 OR LATEST. (Insp. By Consignee) | — | — | — | 42,529.5 | |
| — | 3.00 | — | — | ||
| Taking the all types of cables inside relay rooms, location boxes and junction boxes etc. and sealing of cable entry pit etc. as per Technical specifications, complete with contractors's material. (Insp. By Consignee) | — | — | — | 7,392.03 | |
| — | 6.00 | — | — | ||
| Supply, installation, testing and commissioning of full HD Bullet type IP colour Camera with edge storage capacity 128 GB or higher as per technical specification attached. It includes supply and testing of adapter for direct power purpose for camera. (Insp. By Consignee) | — | — | — | 44,063.76 | |
| — | 6.00 | — | — | ||
| Supply of Class 10 Memory Card 128 GB storage for camera. (Insp. By Consignee) | — | — | — | 10,879.92 | |
| — | 6.00 | — | — | ||
| Supply and installation of Network Video Recorder 32-channel input as per technical specification attached. (Insp. By Consignee) | — | — | — | 2,29,696.38 | |
| — | 6.00 | — | — | ||
| Supply, fixing, testing, connecting andcommissioning of 450 mm sweep Exhaust Fansuitable for 230 volts, 50 Hz AC supply, 1400RPM heavy duty with wiring and flexible PVC pipeas required. (Insp. By Consignee) | — | — | — | 15,425.76 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCCorrectionSlip1to10.pdf
ATTACHMENT
TenderDoc27pageLATESTUpdt..pdf
ATTACHMENT
AnnexureAEmployeedRlyEngg..pdf
ATTACHMENT
Annexure-VIBCATurnOver.pdf
ATTACHMENT
Annexure-VIABidsecurity.pdf
ATTACHMENT
LASTFYDECLARATION.pdf
ATTACHMENT
JPO-05-2023UndertakingtheworkoflayingundergroundSignallingTelecomcablesandEngineering1.pdf
ATTACHMENT
TechspcCameraNVR64itemno.7981.pdf
ATTACHMENT
signalfoundationdrg2.pdf
ATTACHMENT
TechnicalCircular-1-24forDifferentBoardsusedinSingnalling1.pdf
ATTACHMENT
TypicalDiagramforLocationBoxFoundationdrawing_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .